EOS Econ H4 Installation And Operating Instruction

Sauna control unit
Hide thumbs Also See for Econ H4:
Table of Contents

Advertisement

Quick Links

I N N O V A T I V E S A U N A T E C H N O L O G Y
EOS Econ H4
sauna control unit
Installation and operating instruction
EN
Made in Germany
Firmware R4.35
IPx4
Print no. 29344631en / 10.25
Technical changes reserved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Econ H4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EOS Econ H4

  • Page 1 I N N O V A T I V E S A U N A T E C H N O L O G Y EOS Econ H4 sauna control unit Installation and operating instruction Made in Germany Firmware R4.35 IPx4 Print no.
  • Page 2: Table Of Contents

    English Table of contents General information about using the sauna ..................4 General safety precautions ........................5 Scope of Delivery ............................7 Technical data ..............................8 Intended use ..............................9 Installation of the control unit ....................... 10 Wall installation............................. 10 Surface-mounted installation ......................10 Recessed installation .......................... 11 Connecting the sensor cables .......................
  • Page 3 Switching your sauna on / off in dry / humid mode ............26 Temperature query ........................26 Individual settings ..........................27 Cabin temperature ........................27 Humidity mode for time steps (without humidity sensor) ..........28 Humidity regulation (propotional to time) ................29 Humidity regulation (by connected humidity sensor) .............
  • Page 4: General Information About Using The Sauna

    Preface Dear customer, quickly and easily find your way though the programming process. Please note the varia- you have purchased a high-quality electronic tion in temperatures in the cabin while sauna device with which you will enjoy your sauna bathing. The hottest area is directly below the &...
  • Page 5: General Safety Precautions

    General safety precautions be held within operating parameters and a minimal deviation at the bench level of This device may be used by children (age • the sauna cabin can be achieved only if the 8 and above) and by persons with reduced device is installed correctly.
  • Page 6 When designing the sauna cabin, en- Attention! sure that the external exposed glass surfaces Dear customer, may only reach a maximum temperature of according to the valid regulations, the 76 °C. If necessary, protective features need electrical connection of the sauna heater to be fitted.
  • Page 7: Scope Of Delivery

    Scope of delivery (changes without prior notice reserved) The package contents includes: 1. Control unit 2. Temperature sensor, consisiting of: sensor board with overheating protection fuse, KTY-sensor, sensor housing, two 3x25 mm fastening screws and 2,0 m sensor cable. 3. Plastic bag with three 4x25 mm fastening screws. 4.
  • Page 8: Technical Data

    Technical data Voltage (power supply) 400 V 3N AC 50 Hz Switch output max. 9 kW resistive load (AC1 mode) Humidity mode: 6 kW + 3 kW for vaporizer equipment. Can be expanded to 36 kW via the connection of power switching devices Fuse 3 x 16 A Heating time limit:...
  • Page 9: Intended Use

    Intended use This sauna control unit is exclusively intended for the control of the sauna heater in a sauna cabin. Any other use over and above the intended purpose is not considered as appropriate use! Com- pliance of the standard operation, maintenance and repair conditions is also an element of appro- priate use.
  • Page 10: Installation Of The Control Unit

    Installation of the control unit Fasten the housing bottom at the two bot- tom openings (Fig. 4) firmly to the cabin wall. Wall installation The control unit may only be mounted outside the cabin. For sauna rooms it is advisable to se- ca.
  • Page 11: Recessed Installation

    Recessed installation 1. Cut out a wall section that is at least 3.5 cm deep according to the dimension in Fig. 5. 21 cm Fig. 5 Insert the supplied rubber grommets into the openings at the rear wall of the housing and insert the connecting cables through these openings.
  • Page 12: Connecting The Sensor Cables

    Connecting the sensor cables You should not install sensor and power supply 20 cm lines together, or lead them through the same feedthrough. This can lead to interferences in the electronics, such as "fluttering" in the re- lays. If it is necessary to lay the cables down together, or if the line is longer than 3m, use a shielded sensor cable (4 x 0.5 mm²).
  • Page 13 Bore hole Sauna ceiling Centre sensor housing on middle section of the wooden plank. Sensor cables connect to ground (PE) by shielded sensor cable Fig. 11 Notice Equipment damage due to incorrect connection. Mixing up the connection on X2 connection can cause the fuse F2 to blow and damage the control (for replacement please refer to the chapter „Device fuses“) Temperature sensor...
  • Page 14: Installation Of The Optional Bench Sensor

    Installation of the option- By faults of the second sensor the following er- ror messages will be displayed: al second temperature sensor (bench sensor) „Sensor break“ - interruption of the sensor cir- cuit (e.g. faulty contact). Installation place: The bench sensor shall be mounted to the ceiling over the rear wall bench „Sensor short“...
  • Page 15: Climate Control

    Humidity sensor installation Sensor circuit board (optional equipment) 1 2 3 4 1. The humidity sensor shall be mounted in the middle of the side wall which is opposite to the stove at a height of approx. 150 cm. See example below.
  • Page 16: Electrical Connection

    Electrical connection Connecting the vaporizer The electrical connection may only be done by a certified electrician in compliance with the guidelines of the local utility company and the VDE. Use a silicone coated cable 4 x 1.5 mm² to connect In general, there may be only one fixed connec- the vaporizer.
  • Page 17: Connecting The Sauna Lamp

    Connecting the sauna lamp Only use dimmable lighting and ballasts, be- cause otherwise the lights or the control unit will be damaged. The light type will be normally detected automatically. If required can also be set manually. (See paragraph „Manual definition of the lighting type.“) The sauna light must comply to the water splash proof protection class (IPx4) and must be resist-...
  • Page 18: Installation Diagram

    Installation diagram optional = optional oder ECON max. 3 kW 400 V 3 N AC 50 Hz The control lamp for public systems without heat-up time restriction must be installed in the supervisor‘s room. Terminal arrangement on the circuit board Sauna bus Plug for sensor connection Connection...
  • Page 19: Connection Diagram For Sauna Heaters Up To 9 Kw

    Connection diagram for sauna heaters up to 9 kW 139°C ECON ECON L1 L2 L3 WB N V1 N S1 Limiter weiß / white Sensor rot / red max. 100 W max. 100 W 3x16A 120° P max. 9 kW max.
  • Page 20: Connection Diagram For The Vaporizer

    (e.g. EOS cover protection rail) or in weiß/white other manner complies with the EU safety rot/red norms for remote operation.
  • Page 21: Operation

    Operation Once the system has been installed with all components and all covers have been fixed, you can put the control unit into operation. Please read the following information to get yourself familiar with the functions and capabilities of your sauna control unit. General information The user interface MODE...
  • Page 22: Default Display Stand-By

    Default display Stand-by is shown if the system is in Stand-by mode. 12:00 Temperature 90°C The system also returns to this screen from Humidity other menu items, if there is no activity for >15 Auto-stop 5 : 59 - - : - - Start time seconds.
  • Page 23: Symbol Description

    Symbol description 12:00 The following is shown in the top area of the display: Light switches on automatically when heating is switched on Light-Symbol • Light stays on 30 min. after the heating stops • Manual light switching is possible at any time •...
  • Page 24: Operation Principle

    Operation principle For settings press shortly the button. MODE The first parameter (temperature) will be se- lected and shown inverted. 12:00 Use the buttons to navigate to the Temperature 90°C required parameter which you would like to Humidity Auto-Stop 5:59 adjust.
  • Page 25: Initial Commissioning

    Initial commissioning Set language (DE, GB, IT, NL, PL, RU, FR, SE, ES, CZ, FI, SLO) 12:00 12:00 MODE > 3 Sec Set time of day (0:00 bis 23:59) 00:00 00:00 Tageszeit Tageszeit : 00 : 00 MODE 00:00 00:00 Tageszeit Tageszeit 12 :...
  • Page 26: Switching Your Sauna On / Off In Dry / Humid Mode

    Switching your sauna on in a dry (Finnish) mode 12:00 12:15 Temperature 90°C Temperature 90°C Humidity Humidity Auto-stop 5 : 59 Auto-stop 5 : 59 - - : - - - - : - - Start time Start time > 3 sec Switching your sauna off (dry sauna mode) 12:15 12:00...
  • Page 27: Individual Settings

    Individual Settings The following are options for adapting the control systems to your individual needs. The parame- ters can be adjusted both in standby or in operation mode and the changes are then saved in the device. Changes made in operation mode will apply immediately once saved. Cabin temperature Setting range: Dry sauna operation 30 - 115°C...
  • Page 28: Humidity Mode For Time Steps (Without Humidity Sensor)

    Humidity mode for time you the temperature values via the relative air humidity for the most common sauna shapes steps (without humidity and comfort zones. sensor) A prerequisite for humidity mode is the connec- tion of a suitable vaporizer device up to max. 3 Temperature in °C kW at 230 V AC.
  • Page 29: Humidity Regulation (Propotional To Time)

    Humidity regulation (propotional to time) (Range 1-10) If a value is entered by humidity the sauna unit automatically goes into humidity operation when switched on. The vaporizer will switch on for a short time to indicate it is functional and will switch off.
  • Page 30: Humidity Regulation (By Connected Humidity Sensor)

    Humidity regulation (by connected humidity sensor) Humidity intensity: If a value is entered here the sauna unit automatically goes into humidity operation when switched on. In Stand-by In Operation 12:00 12:00 Temperature 60°C Temperature 60°C Humidity 30 % Humidity 30 % Auto-stop 5 : 5 9 Auto-stop...
  • Page 31: Switching Off The Sauna Unit During Humidity Operation

    Switching off the sauna unit during By connected humidity sensor the humidity value shown in the display corresponds to the humidity operation relative air humidity around the humidity sen- To dry out the sauna cabin after the humidity sor. The humidity value is set or shown in the mode, a „sauna-dry mode“...
  • Page 32: Auto-Stop / Heat-Up Time Limitation

    Auto-stop / heat-up time limitation Auto-Stop defines the heating time limitation. The sauna unit automatically turns off once this time has expired. Depending on the configuration of the control unit, a time between 0:30 to 6:00, 0:30 to12:00 hours or unlimited can be set. This setting is valid for all user profiles P1-P4. Attention! The allowed time for private operations is 6 hours.
  • Page 33 12:00 12:00 Temperature 90°C Temperature 90°C Humidity Humidity Auto-stop 3 : 5 9 Auto-stop 3:30 Start time - - : - - Start-time - - : - - > 3 sec. > 3 sec. MODE MODE 12:00 12:00 Temperature 90°C Temperature 90°C Humidity...
  • Page 34: Cabin Lighting

    Cabin lighting Every time that the sauna system is activated, 12:00 the cabin lighting is automatically switched on. Temperature 90°C symbol is shown at the top left of the Humidity display. If the sauna system is switched off, the Auto-stop 5:59 Start-time - -: - -...
  • Page 35: Preselection Time

    Preselection time The switching time preselection function is a timer which allows you to automatically switch your sauna up to 24 h in advance or enable recurring automatic switching. Note: by disabled Safety the time pre-selection will be shown but cannot be programmed. Single-even switching: Set start time up to 24 h in advance and press On/Off button shortly.
  • Page 36: Activate / Deactivate The Preselection Time

    12:15 12:15 Temperature 30°C Temperature 30°C Humidity Humidity 5 : 59 Auto-stop 5 : 59 Auto-stop Start time 17 : Start time 17 : 12:15 12:15 Temperature 30°C Temperature 30°C Humidity Humidity 5 : 59 Auto-stop 5 : 59 Auto-stop 17 : Start time Start time...
  • Page 37: Advanced Settings

    Advanced settings Change language Change time 12:00 12:00 Temperature 90°C Temperature 90°C Humidity Humidity Auto-stop 5 :5 9 Auto-stop 5: 59 Start time - - :-- Start time -- : -- & MODE & MODE 12:15 12:00 Time of day Time of day 12 : 15 12 : 00...
  • Page 38: Switching Between °C And °F

    Switching between °C and °F You can select between °C or °F display if you switch the controler off and then switch it on again while holding the button pressed. 12:00 Temperature 50°C Humidity Auto-stop 5 : 5 9 Start time - - : - - &...
  • Page 39: Activate / Deactivate The Child Lock

    Activate / deactivate the child lock Activate / deactivate the Safety (only with existing safety system) If the child lock is activated (the key symbol is visible in the top section of the display) only the If Safety is not activated, neither the remote cabin lighting can be switched.
  • Page 40: Activate / Deactivate The Life - Guard

    Activate / deactivate the Life - Guard Life - Guard is a settable relatively short time, e.g. 20 minutes, after which the sauna unit is switched off, except for the cabin lighting. After this time has expired the unit can be switched on again by pushing the -button for the set MODE...
  • Page 41: Life-Guard

    Life-Guard Here you can set a short period of time after which the sauna will be automatically switched off (interrupted) and may be immediately restarted for the same period of time by pressing the MODE button. For example, set up 15 minutes. If you do not press the button again after 15 minutes, the sauna heater will switch off.
  • Page 42: Switching On The Sauna Unit With Life-Guard

    Switching on the sauna unit with Life - Guard 12:00 Temperature 90°C Humidity Auto-stop 5 : 5 9 Start time - - : - - Life - Guard 20 min > 3 sec 12:00 Temperature 90°C Humidity Auto-stop 5 : 5 9 Start-time - - : - - Life - Guard...
  • Page 43: Function Principle

    Holiday home mode Holiday park mode Symbol flashes The holiday home mode allows the control In the holiday park mode only the functions system to be locked so that only the essential “heating” and “light” (on/off ) are available. functions are available. The menu language All other functions, including the basic setup, must be selected every time before use.
  • Page 44: Manual Setup Of The Light Type

    Manual setup of the light type On delivery, the light output is set to inductive loads. The control unit supports resistive, inductive or capacitive loads at the light output and can be adjusted accordingly. Note: Automatic detection is not active. It can be selected manually. If there are problems with the automatic detection, the phase edge control can be determined manually.
  • Page 45: Heating Time Limitation

    Heating time limitation The maximal heating time may be set with a jumper on the display printed circuit board to 6 or 12 hours or to unlimited operation time. The jumper is located at the top edge of the board as shown below.
  • Page 46: Device Fuses

    Device fuses The control unit is fitted with two protective fuses which are mounted on the main relay board of the unit. These fuses protect the electronics on the board and the light and fan outputs. Notice: fuses do not mean absolute protection, in an unlikely case of a power surge or a short circuit with particularly fast voltage increase the electronic components may be still be affected.
  • Page 47: Error Messages

    Error messages The control unit continuously monitors the sensor for short circuits and interruptions. At the same time, the system checks to ensure that there is enough water in the vaporizer tank. The error messages appear as follows: Display Cause Remedy 12:00 = interrupted room sensor circuit...
  • Page 48: The Device „Switch-Off" Switch

    The device „Switch-off“ switch The control unit is equipped with a “Switch-off” Switch-off rocker rocker switch. You will find this switch on the top side of the housing by Econ series control units. This switch allows to switch the control unit to the standby mode (notice the heating will not start), to switch the control unit completely off (disconnect from power) or to switch the con-...