Page 1
I N N O V A T I V E S A U N A T E C H N O L O G Y EOS Econ H4 sauna control unit Installation and operating instruction Made in Germany Firmware R4.35 IPx4 Print no.
English Table of contents General information about using the sauna ..................4 General safety precautions ........................5 Scope of Delivery ............................7 Technical data ..............................8 Intended use ..............................9 Installation of the control unit ....................... 10 Wall installation............................. 10 Surface-mounted installation ......................10 Recessed installation .......................... 11 Connecting the sensor cables .......................
Page 3
Switching your sauna on / off in dry / humid mode ............26 Temperature query ........................26 Individual settings ..........................27 Cabin temperature ........................27 Humidity mode for time steps (without humidity sensor) ..........28 Humidity regulation (propotional to time) ................29 Humidity regulation (by connected humidity sensor) .............
Preface Dear customer, quickly and easily find your way though the programming process. Please note the varia- you have purchased a high-quality electronic tion in temperatures in the cabin while sauna device with which you will enjoy your sauna bathing. The hottest area is directly below the &...
General safety precautions be held within operating parameters and a minimal deviation at the bench level of This device may be used by children (age • the sauna cabin can be achieved only if the 8 and above) and by persons with reduced device is installed correctly.
Page 6
When designing the sauna cabin, en- Attention! sure that the external exposed glass surfaces Dear customer, may only reach a maximum temperature of according to the valid regulations, the 76 °C. If necessary, protective features need electrical connection of the sauna heater to be fitted.
Scope of delivery (changes without prior notice reserved) The package contents includes: 1. Control unit 2. Temperature sensor, consisiting of: sensor board with overheating protection fuse, KTY-sensor, sensor housing, two 3x25 mm fastening screws and 2,0 m sensor cable. 3. Plastic bag with three 4x25 mm fastening screws. 4.
Technical data Voltage (power supply) 400 V 3N AC 50 Hz Switch output max. 9 kW resistive load (AC1 mode) Humidity mode: 6 kW + 3 kW for vaporizer equipment. Can be expanded to 36 kW via the connection of power switching devices Fuse 3 x 16 A Heating time limit:...
Intended use This sauna control unit is exclusively intended for the control of the sauna heater in a sauna cabin. Any other use over and above the intended purpose is not considered as appropriate use! Com- pliance of the standard operation, maintenance and repair conditions is also an element of appro- priate use.
Installation of the control unit Fasten the housing bottom at the two bot- tom openings (Fig. 4) firmly to the cabin wall. Wall installation The control unit may only be mounted outside the cabin. For sauna rooms it is advisable to se- ca.
Recessed installation 1. Cut out a wall section that is at least 3.5 cm deep according to the dimension in Fig. 5. 21 cm Fig. 5 Insert the supplied rubber grommets into the openings at the rear wall of the housing and insert the connecting cables through these openings.
Connecting the sensor cables You should not install sensor and power supply 20 cm lines together, or lead them through the same feedthrough. This can lead to interferences in the electronics, such as "fluttering" in the re- lays. If it is necessary to lay the cables down together, or if the line is longer than 3m, use a shielded sensor cable (4 x 0.5 mm²).
Page 13
Bore hole Sauna ceiling Centre sensor housing on middle section of the wooden plank. Sensor cables connect to ground (PE) by shielded sensor cable Fig. 11 Notice Equipment damage due to incorrect connection. Mixing up the connection on X2 connection can cause the fuse F2 to blow and damage the control (for replacement please refer to the chapter „Device fuses“) Temperature sensor...
Installation of the option- By faults of the second sensor the following er- ror messages will be displayed: al second temperature sensor (bench sensor) „Sensor break“ - interruption of the sensor cir- cuit (e.g. faulty contact). Installation place: The bench sensor shall be mounted to the ceiling over the rear wall bench „Sensor short“...
Humidity sensor installation Sensor circuit board (optional equipment) 1 2 3 4 1. The humidity sensor shall be mounted in the middle of the side wall which is opposite to the stove at a height of approx. 150 cm. See example below.
Electrical connection Connecting the vaporizer The electrical connection may only be done by a certified electrician in compliance with the guidelines of the local utility company and the VDE. Use a silicone coated cable 4 x 1.5 mm² to connect In general, there may be only one fixed connec- the vaporizer.
Connecting the sauna lamp Only use dimmable lighting and ballasts, be- cause otherwise the lights or the control unit will be damaged. The light type will be normally detected automatically. If required can also be set manually. (See paragraph „Manual definition of the lighting type.“) The sauna light must comply to the water splash proof protection class (IPx4) and must be resist-...
Installation diagram optional = optional oder ECON max. 3 kW 400 V 3 N AC 50 Hz The control lamp for public systems without heat-up time restriction must be installed in the supervisor‘s room. Terminal arrangement on the circuit board Sauna bus Plug for sensor connection Connection...
Connection diagram for sauna heaters up to 9 kW 139°C ECON ECON L1 L2 L3 WB N V1 N S1 Limiter weiß / white Sensor rot / red max. 100 W max. 100 W 3x16A 120° P max. 9 kW max.
Operation Once the system has been installed with all components and all covers have been fixed, you can put the control unit into operation. Please read the following information to get yourself familiar with the functions and capabilities of your sauna control unit. General information The user interface MODE...
Default display Stand-by is shown if the system is in Stand-by mode. 12:00 Temperature 90°C The system also returns to this screen from Humidity other menu items, if there is no activity for >15 Auto-stop 5 : 59 - - : - - Start time seconds.
Symbol description 12:00 The following is shown in the top area of the display: Light switches on automatically when heating is switched on Light-Symbol • Light stays on 30 min. after the heating stops • Manual light switching is possible at any time •...
Operation principle For settings press shortly the button. MODE The first parameter (temperature) will be se- lected and shown inverted. 12:00 Use the buttons to navigate to the Temperature 90°C required parameter which you would like to Humidity Auto-Stop 5:59 adjust.
Individual Settings The following are options for adapting the control systems to your individual needs. The parame- ters can be adjusted both in standby or in operation mode and the changes are then saved in the device. Changes made in operation mode will apply immediately once saved. Cabin temperature Setting range: Dry sauna operation 30 - 115°C...
Humidity mode for time you the temperature values via the relative air humidity for the most common sauna shapes steps (without humidity and comfort zones. sensor) A prerequisite for humidity mode is the connec- tion of a suitable vaporizer device up to max. 3 Temperature in °C kW at 230 V AC.
Humidity regulation (propotional to time) (Range 1-10) If a value is entered by humidity the sauna unit automatically goes into humidity operation when switched on. The vaporizer will switch on for a short time to indicate it is functional and will switch off.
Humidity regulation (by connected humidity sensor) Humidity intensity: If a value is entered here the sauna unit automatically goes into humidity operation when switched on. In Stand-by In Operation 12:00 12:00 Temperature 60°C Temperature 60°C Humidity 30 % Humidity 30 % Auto-stop 5 : 5 9 Auto-stop...
Switching off the sauna unit during By connected humidity sensor the humidity value shown in the display corresponds to the humidity operation relative air humidity around the humidity sen- To dry out the sauna cabin after the humidity sor. The humidity value is set or shown in the mode, a „sauna-dry mode“...
Auto-stop / heat-up time limitation Auto-Stop defines the heating time limitation. The sauna unit automatically turns off once this time has expired. Depending on the configuration of the control unit, a time between 0:30 to 6:00, 0:30 to12:00 hours or unlimited can be set. This setting is valid for all user profiles P1-P4. Attention! The allowed time for private operations is 6 hours.
Page 33
12:00 12:00 Temperature 90°C Temperature 90°C Humidity Humidity Auto-stop 3 : 5 9 Auto-stop 3:30 Start time - - : - - Start-time - - : - - > 3 sec. > 3 sec. MODE MODE 12:00 12:00 Temperature 90°C Temperature 90°C Humidity...
Cabin lighting Every time that the sauna system is activated, 12:00 the cabin lighting is automatically switched on. Temperature 90°C symbol is shown at the top left of the Humidity display. If the sauna system is switched off, the Auto-stop 5:59 Start-time - -: - -...
Preselection time The switching time preselection function is a timer which allows you to automatically switch your sauna up to 24 h in advance or enable recurring automatic switching. Note: by disabled Safety the time pre-selection will be shown but cannot be programmed. Single-even switching: Set start time up to 24 h in advance and press On/Off button shortly.
Advanced settings Change language Change time 12:00 12:00 Temperature 90°C Temperature 90°C Humidity Humidity Auto-stop 5 :5 9 Auto-stop 5: 59 Start time - - :-- Start time -- : -- & MODE & MODE 12:15 12:00 Time of day Time of day 12 : 15 12 : 00...
Switching between °C and °F You can select between °C or °F display if you switch the controler off and then switch it on again while holding the button pressed. 12:00 Temperature 50°C Humidity Auto-stop 5 : 5 9 Start time - - : - - &...
Activate / deactivate the child lock Activate / deactivate the Safety (only with existing safety system) If the child lock is activated (the key symbol is visible in the top section of the display) only the If Safety is not activated, neither the remote cabin lighting can be switched.
Activate / deactivate the Life - Guard Life - Guard is a settable relatively short time, e.g. 20 minutes, after which the sauna unit is switched off, except for the cabin lighting. After this time has expired the unit can be switched on again by pushing the -button for the set MODE...
Life-Guard Here you can set a short period of time after which the sauna will be automatically switched off (interrupted) and may be immediately restarted for the same period of time by pressing the MODE button. For example, set up 15 minutes. If you do not press the button again after 15 minutes, the sauna heater will switch off.
Switching on the sauna unit with Life - Guard 12:00 Temperature 90°C Humidity Auto-stop 5 : 5 9 Start time - - : - - Life - Guard 20 min > 3 sec 12:00 Temperature 90°C Humidity Auto-stop 5 : 5 9 Start-time - - : - - Life - Guard...
Holiday home mode Holiday park mode Symbol flashes The holiday home mode allows the control In the holiday park mode only the functions system to be locked so that only the essential “heating” and “light” (on/off ) are available. functions are available. The menu language All other functions, including the basic setup, must be selected every time before use.
Manual setup of the light type On delivery, the light output is set to inductive loads. The control unit supports resistive, inductive or capacitive loads at the light output and can be adjusted accordingly. Note: Automatic detection is not active. It can be selected manually. If there are problems with the automatic detection, the phase edge control can be determined manually.
Heating time limitation The maximal heating time may be set with a jumper on the display printed circuit board to 6 or 12 hours or to unlimited operation time. The jumper is located at the top edge of the board as shown below.
Device fuses The control unit is fitted with two protective fuses which are mounted on the main relay board of the unit. These fuses protect the electronics on the board and the light and fan outputs. Notice: fuses do not mean absolute protection, in an unlikely case of a power surge or a short circuit with particularly fast voltage increase the electronic components may be still be affected.
Error messages The control unit continuously monitors the sensor for short circuits and interruptions. At the same time, the system checks to ensure that there is enough water in the vaporizer tank. The error messages appear as follows: Display Cause Remedy 12:00 = interrupted room sensor circuit...
The device „Switch-off“ switch The control unit is equipped with a “Switch-off” Switch-off rocker rocker switch. You will find this switch on the top side of the housing by Econ series control units. This switch allows to switch the control unit to the standby mode (notice the heating will not start), to switch the control unit completely off (disconnect from power) or to switch the con-...
2012/19/EU. Do not dispose it with the normal household waste. Service Address: EOS Saunatechnik GmbH Schneiderstriesch 1 35759 Driedorf, Germany Tel: +49 (0)2775 82-514 Fax: +49 (0)2775 82-431 servicecenter@eos-sauna.de...
The manufacturers General Terms and Conditions of Business, which can be found at www.eos-sauna.com/ V. Liability agb, shall apply in addition to the foregoing terms and conditions of service.
Need help?
Do you have a question about the Econ H4 and is the answer not in the manual?