Advertisement

Quick Links

DIGICHLOR
mineral chlorinator
Owners Manual
THIS PRODUCT CONTAINS A BUTTON BATTERY
If swallowed, a lithium button battery can cause severe or fatal injuries
within 2 hours. Keep batteries out of reach of children. If you think bat-
teries may have been swallowed or placed inside any part of the body,
seek immediate medical attention.
This equipment must be installed and serviced by a qualified technician.
WARNING
!
Improper installation can create electrical hazards which could result in
property damage, serious injury or death. Improper installation will void
the warranty.
www.waterco.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIGICHLOR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Waterco DIGICHLOR

  • Page 1 DIGICHLOR mineral chlorinator Owners Manual THIS PRODUCT CONTAINS A BUTTON BATTERY If swallowed, a lithium button battery can cause severe or fatal injuries within 2 hours. Keep batteries out of reach of children. If you think bat- teries may have been swallowed or placed inside any part of the body, seek immediate medical attention.
  • Page 2: Table Of Contents

    Table of GENERAL SAFETY RULES --------------------------------------- 01 WHAT’S IN THE BOX? -------------------------------------------- 02 FEATURES ---------------------------------------------------------- 02 DIGICHLOR --------------------------------------------------------- 02 Digichlor Control Unit ------------------------------------------ 02 Digital Timer ----------------------------------------------------- 02 Electrolytic Salt Cell -------------------------------------------- 03 Self-Cleaning ---------------------------------------------------- 03 Battery Backup -------------------------------------------------- 03...
  • Page 3: General Safety Rules

    Waterco Digichlor I pg 01 GENERAL SAFETY RULES 1) The equipment mentioned in this manual is specially designed for the sanitizing of water in swimming pools. 2) It is designed to work with clean water at a temperature not exceeding 35°C (95°F).
  • Page 4: What's In The Box

    A salt- water chlorinated pool requires much less attention than a chlorine pool. DIGICHLOR Digichlor consists of a Control Unit (power supply)with a built in digital timer and a electrolytic salt cell (where the chlorine is produced). Digichlor Control Unit The Control Unit monitors and regulates chlorine production by regulating the amount of electrical energy supplied to the electrolytic salt cell.
  • Page 5: Electrolytic Salt Cell

    Waterco’s Self Clean Salt Cell has the added ability to reverse the polarity of the voltage to clean calcium build up off its electrodes. The Digichlor Control Unit power up the salt cell (anode and cathode) and hold an electrical potential difference between them for a designated period of time. This difference is reversed after that period of time has expired and then the anode becomes the cathode and the cathode becomes the anode.
  • Page 6: Automatic Pool Cover Link

    A harness connector is provided to act as switch during the deployment of the pool cover. The harness is located at the bottom of the Digichlor as shown in the following figure: Note: This feature is only available in the Europe model.
  • Page 7: Plumbing Diagram

    Waterco Digichlor I pg 05 Heat Pump Water Out Vertical Trap Water By-pass POOL Check Valve Water In To Spa Filter DIGICHLOR ELECTROLYTIC CELL Chlorinator or Chlorine Generator To Pool POOL 3 Way Valve From Pool From Spa PLUMBING DIAGRAM...
  • Page 8: Installing/Connecting Electrolytic Cell

    Cell Connections NOTE: Connect all plumbing to the Cell Housing taking care that all joints are glued or tightened securely to prevent leaking. Allow 24 hours for glue (solvent) to set before starting the Digichlor. Digital Timer Functions Digital Screen...
  • Page 9: Operation

    Setting the Timer There is only one (1) timer mode. To set up timer for when Digichlor will operate, turn the dial until you reach ‘set timer’. Press on the dial to ‘enter’ the function. 2. Press the dial again to highlight the timer hand to yellow and turn the dial to a time you want the Digichlor to operate.
  • Page 10: Super Chlorination Mode

    AUTO Mode This is the default operation mode. Timers are operational according to programmed settings. OFF Mode Digichlor is permanently turned OFF when this is selected and will need to be manually turned on again. Auto Position Off Position Manual Position...
  • Page 11: Chlorine Production Levels

    Pump Only mode LED is lit. ALARMS In addition to the ‘Diagnostics’ mode, Digichlor also includes alarm signals to indicate potential problems associated with its functionality and to protect the control unit/ electrolytic cell. The chlorine production LEDs will blink/lit or change the colour to indicate the correspondent situation.
  • Page 12: Water Chemistry

    Reconnect the salt cell onto the filter system h. Set the unit back to original “ON” or “AUTO” position to reactivate the Digichlor. Never use products that are not specifically manufactured to clean the Digichlor MK3’s salt cell.
  • Page 13: Troubleshooting

    Control unit set to pump only Press Chlorine Production button to set the desired level Digichlor is on OFF mode Set Digichlor to ON or AUTO mode Pump not working Pump not connected to pump Plug pump lead to Pump Socket...
  • Page 14: Technical Specifications

    TECHNICAL SPECIFICATIONS Power Unit Waterco Salt Cell Input 220-240V AC Input 20V DC Frequency 50/60 Hz Maximum Current 4A DC Output Current 0.3 A Socket Outlet 220-240V AC Maximum Current Output Minimum Salt Level 4000 TDS Maximum Salt Level 6000 TDS...
  • Page 15 Waterco Digichlor I pg 13 Note:...
  • Page 16 Tel: +61 8 8244 6000 Tel: +64 9 525 7570 Tel: +65 6344 2378 ACT DISTRIBUTION WATERCO VIETNAM COMPANY LIMITED Tel: +61 2 6280 6476 Ho Chi Minh City, Vietnam. Tel: +84 28 3622 7780 Waterco Limited ABN 62 002 070 733 W99466 11/2024...

Table of Contents