Waterco Commandomatic Ezysoft Manual For Use And Installation

Waterco Commandomatic Ezysoft Manual For Use And Installation

Water softener system

Advertisement

Quick Links

Commandomatic Ezysoft
WATER SOFTENER SYSTEM
Manual
This equipment must be installed and serviced by a qualified technician.
!
WARNING
Improper installation can create electrical hazards which could result in property
damage, serious injury or death. Improper installation will void the warranty.
Notice to Installer
This manual contains important information about the installation, operation
and safe use of this product. Once the product has been installed this manual
must be given to the owner / operator of this equipment.
www.waterco.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Commandomatic Ezysoft and is the answer not in the manual?

Questions and answers

Summary of Contents for Waterco Commandomatic Ezysoft

  • Page 1 Commandomatic Ezysoft WATER SOFTENER SYSTEM Manual This equipment must be installed and serviced by a qualified technician. WARNING Improper installation can create electrical hazards which could result in property damage, serious injury or death. Improper installation will void the warranty.
  • Page 2: Table Of Contents

    Table of INTRODUCTION --------------------------------------------------- 03 GENERAL INFORMATION ---------------------------------- 03 1.2. WATER SOFTENERS -------------------------------------- 03 1.3. ADVANTAGES OF USING EZYSOFT --------------------- 03 1.4. KEY FEATURES -------------------------------------------- 03 OPERATING CONDITIONS AND REQUIREMENTS -------- 04 HOW THE SYSTEM WORKS -------------------------------- 05 INSTALLATION ---------------------------------------------- 06 4.2.
  • Page 3 Waterco Commandomatic Ezysoft I pg 01 WARNING & SAFETY INSTRUCTIONS • Before you begin the installation of the water softener, we advise you read and carefully follow the instructions contained in this manual. It contains important information about safety, installation, use and maintenance of the product.
  • Page 4 For future reference, fill in the following data INSTALLATION RECORD Serial Number Model Water Hardness inlet Water Hardness outlet Water Pressure inlet Date of Installation Company Name Installer Name Phone Number REGEN. FREQUENCY : ________ days LENGTH OF REGEN. : _________ minutes...
  • Page 5: Introduction

    Waterco Commandomatic Ezysoft I pg 03 INTRODUCTION This booklet is designed to cover the Waterco Ezysoft semi automatic domestic water softeners. 1. GENERAL INFORMATION 1.2. WATER SOFTENERS Hard water contains dissolved minerals in the form of Calcium (Ca), Magnesium (Mg), and Iron (Fe).
  • Page 6: Operating Conditions And Requirements

    2. OPERATING CONDITIONS AND REQUIREMENTS • OPERATING PRESSURE: min. 140 / max. 830 kPa − This system is configured to perform optimally at an operating pressure of 300 kPa (±50 kPa); in case of a lower or higher operating pressure the performance may be affected negatively.
  • Page 7: How The System Works

    I pg 05 3. HOW THE SYSTEM WORKS The Commandomatic Ezysoft is a semi-automatic water softener. When the drain paddle is opened, the valve is automatically transferred to the regeneration position; with its few moving parts, this simple and reliable system guarantees years of trouble-free service.
  • Page 8: Installation

    4. INSTALLATION To facilitate the installation process, remove the salt lid and main cover from the water softener. 4.2. CONNECTING INLET & OUTLET Screw the factory bypass onto the elbow connections of the water softener (2&3); make sure to install the gasket seals. Tighten the nuts firmly by hand. II.
  • Page 9: The Drain

    Waterco Commandomatic Ezysoft I pg 07 4.3. THE DRAIN Connect a 13 mm hose to the drain of the control valve (1); secure it by means of a clamp. II. Run the drain hose to the sewerage system and connect it to the stand pipe assuring sufficient air gap.
  • Page 10: Start Up

    5. START UP When installation has been completed, the unit is ready to be placed into service. Proceed as follows, while checking the unit for any leakages: Place unit in bypass and turn on main water supply; open a cold water tap nearby and allow water to run for a few minutes until all foreign material that may have resulted from the installation is washed out;...
  • Page 11: Initiate A Regeneration

    Waterco Commandomatic Ezysoft I pg 09 6. INITIATE A REGENERATION The semi-automatic timer must be manually initiated; by turning the timer knob clockwise past 30 min, the drain paddle is opened and the valve is transferred to the brine/slow rinse position; the length of this cycle can then be set between 0 and 120 min.
  • Page 12 Calculate the total Hardness. Usually chemical analyses report Calcium (Ca) and Magnesium in terms of parts per million (ppm) as Calcium Carbonate (CaCO3). However, in some cases, the analysis is reported in terms of the elements themselves. If this is the case, proceed as follow: Calcium (as Ca)_______x 2.50 = _______ppm Ca as CaCO Magnesium (as Mg)_______x 4.10 =_______ppm Mg as CaCO (A)_______ + (B) _______ = _______ Total Hardness ppm as CaCO...
  • Page 13: Maintenance

    Waterco Commandomatic Ezysoft I pg 11 8. MAINTENANCE 8.2. BYPASSING THE WATER SOFTENER Occasionally it may be necessary to put the unit hydraulically in bypass, i.e. to isolate it from the water distribution system; e.g.: • in case of an urgent technical problem;...
  • Page 14: Adding Salt

    8.3. ADDING SALT Be sure to use Commandomatic salt (approximately 1/4” pellets), as it is specially selected large granule salt, graded for maximum efficiency and packed in 25kg moisture proof bags. This will prevent “bridging”, as would occur if fine salt were used. Your brine tank holds 50kg – or 2 bags of salt.
  • Page 15: Injector

    Waterco Commandomatic Ezysoft I pg 13 9.2. INJECTOR Remove the 3 screws holding the injector cover plate in place. II. Lift off the injector cover plate. III. Remove the injector and injector gasket. IV. Remove the injector filter and check for dirt or clogging.
  • Page 16: Body Stem Assembly

    9.6. BODY STEM ASSEMBLY Remove the drain hose from the drain line fitting. II. Remove the 4 timer head screws and pull away the timer head assembly. III. Pull forward the main diaphragm; put 2 fingers behind the membrane and pull out the body stem assembly. IV.
  • Page 17: Annual Maintenance

    Waterco Commandomatic Ezysoft I pg 15 XII. Lubricate the threads, the top of the riser tube and the tank O-ring of the control valve. XIII. Lower the control valve straight down onto the riser tube and screw it onto the tank.
  • Page 18 VALVE FAILS TO DRAW BRINE Cause Solution 1. Low operating pressure 1. Verify operating pressure; must exceed 140kPa 2. Open drain flow adjuster slowly until unit 2. Drain flow adjuster too much closed draws brine 3. Plugged injector 3. Clean injector 4.
  • Page 19 Waterco Commandomatic Ezysoft I pg 17 DRAIN FLOW ADJUSTER !!! ATTENTION When the valve is equipped with an incorporated drain flow control (optional), the drain flow adjuster is When the valve is equipped with an incorporated drain flow control (optional), the drain flow adjuster...
  • Page 20: Exploded Diagrams

    11. EXPLODED DIAGRAMS 11.2. SYSTEM EXPLODE DIAGRAM (Include Components of Fully Automatic Units)
  • Page 21 Waterco Commandomatic Ezysoft I pg 19 Parts List (System) ITEM PART NUMBER DESCRIPTION 72515760 Pressure tank, 9x35 Softening resin 72515771 Riser tube assembly with deflector 72515767 Top distributor 72515770 Connection kit ¾” male 377872640 Control valve assembly 72515761 Cover assembly...
  • Page 22 Parts List (System) ITEM PART NUMBER DESCRIPTION Screw, back cap (4x) Back cap Gasket, back cap Spring, check disc Check disc Screw, cover plate (3x) Cover plate, injector 72515774 Injector disc #5 72515775 Gasket, injector 72515776 Filter, injector Locking plate, drain flow adjuster Screw, locking plate Spring clip Brine draw restrictor 1,0 mm (black)
  • Page 23: Technical Specifications

    Waterco Commandomatic Ezysoft I pg 21 12. TECHNICAL SPECIFICATIONS Operating pressure min/max (kPa) 140/830 Operating temperature min/max (°C) 2/48 Electrical connection (V/Hz) None Maximum power consumption (VA) None Hydraulic connection inlet/outlet ¾” BSP Male PERFORMANCES @ 3 BAR OPERATING PRESSURE AND BRINING OF 125GR/LTR OF RESIN(2):...
  • Page 24 Tel : +65 6344 2378 Tel : +33 (0)4 72 79 33 30 ACT Distributor Waterco (NZ) Limited Tel : +61 2 6280 6476 Auckland, New Zealand Tel : +64 9 525 7570 Waterco Limited ABN 62 002 070 733 (ZZM1448) 02/2013...

Table of Contents