HYDROCHLOR ST mineral chlorinator Owners Manual This equipment must be installed and serviced by a qualified technician. WARNING Improper installation can create electrical hazards which could result in property damage, serious injury or death. Improper installation will void the warranty.
Table of What’s in the Box? .................. 01 FEATURES ....................01 HYDROCHLOR ST ................... 01 Hydrochlor ST Control Unit ............01 Time Switch ................... 01 Electrolytic Salt Cell ................02 Self-Cleaning ..................02 Battery Back up ................... 02 INSTALLATION ..................02 PLUMBING DIAGRAM ................
Waterco Hydrochlor ST I pg 01 What’s In the Box? • Hydrochlor ST Control Unit • Manual Warranty Booklet NOTE: If bought as Salt Water Chlorinator unit, the electrolytic cell is provided in a separate carton. FEATURES Chlorine Generation Through the process of electrolysis, a saline solution pass over an electrolytic cell, then the saline solution is separated into its basic components: chlorine and sodium.
Self-Cleaning Waterco’s Self Clean Salt Cell has the added ability to reverse the polarity of the voltage to clean calcium build up off its electrodes. The Hydrochlor Control Unit power up the salt cell (anode and cathode) and hold an electrical potential difference between them for a designated period of time.
Waterco Hydrochlor ST I pg 03 GAS TRAP: The cell must be positioned in such a way as to provide a gas trap. The bottom of the cell must be above the top surface of the pipe from the previous piece of equipment, as per the below diagram.
Cell Connections NOTE: Connect all plumbing to the Cell Housing taking care that all joints are glued or tightened securely to prevent leaking. Allow 24 hours for glue (solvent) to set before starting the Hydrochlor ST. OPERATION Setting the time To set current time, rotate minute hand until arrow-head aligns with correct time.
ON Position: the timer is permanently ON irrespective of tappet positions. This is the recommended setting to work in combination with Waterco’s Aquamaster or ChemfloPlus. AUTO Position: the timer is operating on timed control as determined by tappet positions. This the automatic operation position.
WATER CHEMISTRY Salt Level The Hydrochlor ST chlorinators must operate between the salt level ranges listed below. • MINIMUM = 4000 TDS • OPTIMUM = 5500 TDS • MAXIMUM = 6000 TDS Testing kits are available from the local pool professional and should be used to accurately check the salt level in the pool water.
Production control set too low Set production higher Low salt Add required amount of salt Pool chemistry not correct Have water tested No electrical power Connect power, check fuse, Unit does not operate Hydrochlor ST switch off switch on Hydrochlor ST...
No flow detected Check pool water level Check position of multiport valve Check connection of flow sensor pin TECHNICAL SPECIFICATIONS Power Unit Waterco Salt Cell Input 220-240V AC Input 20V DC Frequency 50/60 Hz Maximum Current Output...