HYDROCHLOR ® Rainbow Pool Products ® PO Box 2388, Mansfield Qld 4122 Telephone STD 61-7-3849 5385 Facsimile STD 61-7-3849 5384 Email: info@rainbowpoolproducts.com.au Web: www.rainbowpoolproducts.com.au This equipment must be installed and serviced by a qualified technician. WARNING Improper installation can create electrical hazards which could result in property damage, serious injury or death.
• 40/50 Bushes • Cables to connect the Self Cleaning Cell • Manual • Waterco’s Warranty Terms and Conditions. FEATURES The Hydrochlor® will automatically maintain the chlorine level of your pool and eliminate problems associated with periods of very high or low chlorine levels. Fewer fluctuations in chlorine levels mean fewer fluctuations in pH levels.
Page 4
There are 8 keys which are used for setting the Time, Timers and operating Modes. The function of these keys is described below: HOME Display current Time of Day or to exit Timers setting. TIMER Toggle between START and FINISH of Timer 1 and Timer 2 for summer and then for winter.
Waterco Hydrochlor® I pg 03 Electrolytic Salt Cell The Hydrochlor®’s salt cell consists of a series of titanium electrodes with opposite charges. Hydrochlor®’s clear salt cell housing allows visual inspection of the salt cell plates and enables monitoring of chlorine production.
INSTALLATION These guidelines should be followed to install the Hydrochlor®: a. Ensure that the chlorinator cell is the last piece of equipment installed on the ltration system – this is so the chlorine produced will not damage other equipments such as heaters. b.
Waterco Hydrochlor® I pg 05 EZY TIMER SETTING Setting a New Time I. Press HOME key to ensure current time is displayed. II. Press HOURS key, to change hours. III. Press MIN key, to change the minutes. IV. Current time is now set.
Overnight Operation To program the Hydrochlor® to function a period of time that involves starting before midnight and ending after midnight, it has to be divided in two periods. For example: If it required to start at 23:00 and nish at 07:00. Then the Electrochlor LCD setting should be break into 2 program periods like this: •...
Waterco Hydrochlor® I pg 07 Note: When the LED lights ash it is an indication of: • Low salt level • Low temperature or • Cell plates wearing If you don’t know what your salt level is or how to test it, consult your local pool care specialist.
TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE REMEDY Low chlorine level in pool Operating time too short Increase operating time Production control set too low Set production higher Low salt Add required amount of salt Pool chemistry not correct Have water tested Unit does not operate No electrical power Connect power, check fuse, Hydrochlor®...