Waterco ELECTROCHLOR PLUS Owner's Manual
Waterco ELECTROCHLOR PLUS Owner's Manual

Waterco ELECTROCHLOR PLUS Owner's Manual

Mineral chlorinator

Advertisement

OFFICES – AUSTRALIA
OFFICES – OVERSEAS
NSW - SydNey
WATerCO (eurOPe) lIMITed
(HeAd OFFICe)
Sittingbourne, Kent, uK
Tel
: +61 2 9898 8600
Tel
: +44 (0) 1795 521 733
VIC/TAS - MelbOurNe
WATerCO uSA
Tel
: +61 3 9764 1211
Augusta, uSA
Tel
: +1 706 793 7291
WA - PerTH
Tel
: +61 8 9273 1900
WATerCO CANAdA
boucherville, QC, Canada
Qld - brISbANe
Tel
: +1 450 748 1421
Tel
: +61 7 3299 9900
WATerCO (NZ) lIMITed
SA/NT - AdelAIde
Auckland, New Zealand
Tel
: +61 8 8244 6000
Tel
: +64 9 525 7570
ACT dISTrIbuTOr
Tel
: +61 2 6280 6476
Waterco Limited ABN 62 002 070 733
(W99368) 09/2018
WATerCO (C) lIMITed
Guangzhou, China
Tel
: +8620 3222 2180
WATerCO (FAr eAST) SdN bHd
Selangor, Malaysia
Tel
: +60 3 6145 6000
PT WATerCO INdONeSIA
Jakarta, Indonesia
Tel
: +62 21 4585 1481
WATerCO SINGAPOre INTl PTe lTd
Nehsons building, Singapore
Tel : +65 6344 2378
ELECTROCHLOR
Mineral Chlorinator PLUS
Owner's Manual
This equipment must be installed and serviced by a qualified technician.
!
WARNING
Improper installation can create electrical hazards which could result in
property damage, serious injury or death. Improper installation will void the
warranty.
Notice to Installer
This manual contains important information about the installation, operation
and safe use of this product. Once the product has been installed this manual
must be given to the owner/operator of this equipment.
®
www.waterco.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELECTROCHLOR PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Waterco ELECTROCHLOR PLUS

  • Page 1 ACT dISTrIbuTOr and safe use of this product. Once the product has been installed this manual : +61 2 6280 6476 must be given to the owner/operator of this equipment. www.waterco.com Waterco Limited ABN 62 002 070 733 (W99368) 09/2018...
  • Page 2: Table Of Contents

    electrochlor Mineral Chlorinator Plus I 03 Table of This equipment must be installed and serviced by a qualified technician. Improper installation can create electrical hazards which could result in Warning property damage, serious injury or death. Improper installation will void the warranty.
  • Page 3: General Safety Rules

    04 I electrochlor Mineral Chlorinator Plus electrochlor Mineral Chlorinator Plus I 05 GENERAL SAFETY RULES 1. WHAT’S IN THE BOX? The equipment mentioned in this manual is specially designed for the sanitizing of • electrochlor Power Pack water in swimming pools. •...
  • Page 4: Introduction

    The Power Pack should not be mounted in areas where chemicals are Warning Waterco’s salt cell consists of a series of titanium electrodes with opposite charges. stored (e.g. acid and chlorine). Waterco’s clear salt cell housing is constructed using clear u.V. stabilized acrylic, and allows visual inspection of the salt cell plates.
  • Page 5 08 I electrochlor Mineral Chlorinator Plus electrochlor Mineral Chlorinator Plus I 09 resetable Fuse To access the electrochlor for connection of cabling and sensors, there are screw wells in each corner of the front panel. To open the panel, insert a flat blade screwdriver and bottom View electrochlor Mineral Plus Chlorinator half turn anti-clock wise to release the spring-loaded locking pin.
  • Page 6: Installing The Chemical Injection Points

    10 I electrochlor Mineral Chlorinator Plus electrochlor Mineral Chlorinator Plus I 11 4. INSTALLING THE CHEMICAL INJECTION POINTS 4.1. The acid injection point is to be installed on the pool return line, after all other pool equipment. 4.2. dry fit the chemical injection point saddle to ensure sufficient space and clearances.
  • Page 7: Connect The Chemical Supply Tubes

    12 I electrochlor Mineral Chlorinator Plus electrochlor Mineral Chlorinator Plus I 13 5. CONNECT THE CHEMICAL SUPPLY TUBES 6. CONNECT CHEMICAL INJECTION POINTS TO THE CHEMICAL DOSING UNIT The electrochlor pH is supplied with ample chemical supply tubes which may be cut to length using a sharp utility knife.
  • Page 8: Assemble The Foot Filter

    14 I electrochlor Mineral Chlorinator Plus electrochlor Mineral Chlorinator Plus I 15 7. ASSEMBLE THE FOOT FILTER 8. ELECTROCHLOR MAINTENANCE Position the chemical drums in a safe and secure location, preferably about 2 The electrochlor ensures that the correct residual level of pH is maintained metres from electrochlor Power Pack.
  • Page 9: Installing The Ph Sensor

    16 I electrochlor Mineral Chlorinator Plus electrochlor Mineral Chlorinator Plus I 17 9. INSTALLING THE PH SENSOR DAILY MAINTENANCE • Clean skimmer baskets if required. 9.1. The pH sensor is to be installed on the pool suction line, before acid injection •...
  • Page 10: Setting The Ph Setpoint

    The electrochlor use a proportional controller using a calculated percentage between two set values that enable or disable the pH dosing pump. Push the electrochlor Plus wheel, navigate to the Settings Menu. Navigate using the arrow to Setpoint Menu. Figure 10.4 Define dosing pump duty Setting the Setpoint and Pump Duties Select the high value, in this example 7.6pH, the select the duty (%) in the below...
  • Page 11: Calibrating The Sensor

    Mineral Chlorinator Plus electrochlor Mineral Chlorinator Plus I 21 Table 10.1 Reference pH Settings for Different Pool Sizes 11. CALIBRATING THE SENSOR This step requires a pH 7.00 reference solution (Waterco P/N 60121387). This step Pool Size Range Proportion (%) Response rate requires the sensor to be removed from its saddle clamp.
  • Page 12: Chemical Handling

    22 I electrochlor Mineral Chlorinator Plus 12. CHEMICAL HANDLING Calibration Procedure: 11.1 Switch the pool pump OFF and unplug it from the POOL PUMP GPO. Important Safety Measures 11.2 remove the pH sensor from the tapping saddle. For installations where this •...