WAGO-I/O-SYSTEM 750
16DI 24V DC 3.0ms, ribbon cable, low-side
switching
750-1402
16-Channel Digital Input Module 24 V DC, Ribbon
cable, low-side switching
Version 1.1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 750 and is the answer not in the manual?

Questions and answers

Summary of Contents for WAGO 750

  • Page 1 Manual WAGO-I/O-SYSTEM 750 16DI 24V DC 3.0ms, ribbon cable, low-side switching 750-1402 16-Channel Digital Input Module 24 V DC, Ribbon cable, low-side switching Version 1.1.0...
  • Page 2 WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching © 2013 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 – 0 Fax: +49 (0) 571/8 87 –...
  • Page 3: Table Of Contents

    Subject to Changes ................9 2.1.2 Personnel Qualifications ............... 9 2.1.3 Use of the 750 Series in Compliance with Underlying Provisions ..9 2.1.4 Technical Condition of Specified Devices ......... 10 Safety Advice (Precautions) ..............11 Device Description ..................13 View ......................
  • Page 4 Table of Contents WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching 8.2.1 Special Conditions for Safe Operation of the ATEX and IEC Ex (acc. DEMKO 08 ATEX 142851X and IECEx PTB 07.0064) ....34 8.2.2 Special conditions for safe use (ATEX Certificate TÜV 07 ATEX 554086 X) ...................
  • Page 5: Notes About This Documentation

    This documentation is only applicable to the I/O module 750-1402 (16DI 24V DC 3.0ms, ribbon cable, low-side switching) of the WAGO-I/O-SYSTEM 750 series. The I/O module 750-1402 shall only be installed and operated according to the instructions in this manual and in the manual for the used fieldbus coupler/controller.
  • Page 6: Symbols

    Notes about this Documentation WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Symbols Personal Injury! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury. Personal Injury Caused by Electric Current! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 7 WAGO-I/O-SYSTEM 750 Notes about this Documentation 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Additional Information: Refers to additional information which is not an integral part of this documentation (e.g., the Internet). Manual Version 1.1.0...
  • Page 8: Number Notation

    Notes about this Documentation WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Number Notation Table 1: Number notation Number code Example Note Decimal Normal notation Hexadecimal 0x64 C notation Binary '100' In quotation marks, nibble separated with '0110.0100'...
  • Page 9: Important Notes

    2.1.2 Personnel Qualifications All sequences implemented on Series 750 devices may only be carried out by electrical specialists with sufficient knowledge in automation. The specialists must be familiar with the current norms and guidelines for the devices and automated environments.
  • Page 10: Technical Condition Of Specified Devices

    The components to be supplied Ex Works, are equipped with hardware and software configurations, which meet the individual application requirements. WAGO Kontakttechnik GmbH & Co. KG will be exempted from any liability in case of changes in hardware or software as well as to non-compliant usage of components.
  • Page 11: Safety Advice (Precautions)

    Installation only in appropriate housings, cabinets or in electrical operation rooms! The WAGO-I/O-SYSTEM 750 and its components are an open system. As such, install the system and its components exclusively in appropriate housings, cabinets or in electrical operation rooms. Allow access to such equipment and fixtures to authorized, qualified staff only by means of specific keys or tools.
  • Page 12 Important Notes WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Do not use any contact spray! Do not use any contact spray. The spray may impair contact area functionality in connection with contamination. Do not reverse the polarity of connection lines! Avoid reverse polarity of data and power supply lines, as this may damage the devices involved.
  • Page 13: Device Description

    With consideration of the power jumper contacts, the individual modules can be arranged in any combination when configuring the fieldbus node. An arrangement in groups within the group of potentials is not necessary. The I/O module 750-1402 can be used with all fieldbus couplers/controllers of the WAGO-I/O-SYSTEM 750. Manual...
  • Page 14: View

    Device Description WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching View Figure 1: View Table 3: Caption acc. to figure “View” Designation Description Details see chapter Marking possibility with Mini-WSB Status-LEDs “Device description” > 1 … 16 Inputs DI 1 …...
  • Page 15: Connectors

    WAGO-I/O-SYSTEM 750 Device Description 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Connectors 3.2.1 Data Contacts/Internal Bus Communication between the coupler/controller and the I/O modules as well as the system supply of the I/O modules is carried out via the internal bus. It is comprised of 6 data contacts, which are available as self-cleaning gold spring contacts.
  • Page 16: Ribbon Cable And Cage Clamp

    Device Description WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching ® 3.2.2 Ribbon Cable and CAGE CLAMP Connectors Table 4: Connections Connection Channel Designation Function Input Input DI 1: Signal voltage DI 1 Input Input DI 2: Signal voltage...
  • Page 17: Display Elements

    WAGO-I/O-SYSTEM 750 Device Description 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Display Elements Table 5: Display Elements Desig- LED Channel State Function nation State Input DI 1: Signal voltage (0) DI 1 green Input DI 1: Signal voltage (1)
  • Page 18: Schematic Diagram

    Device Description WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Schematic Diagram Figure 5: Schematic diagram Manual Version 1.1.0...
  • Page 19: Technical Data

    WAGO-I/O-SYSTEM 750 Device Description 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Technical Data 3.6.1 Device data Table 6: Technical data device Width 12 mm Height (from upper edge of 35 DIN rail) 73 mm Depth 100 mm Weight...
  • Page 20: Approvals

    The following approvals have been granted to 750-1402 I/O modules: Conformity Marking UL508 The following Ex approvals have been granted to 750-1402 I/O modules: TÜV 07 ATEX 554086 X I M2 Ex d I Mb II 3 G Ex nA IIC T4 Gc II 3 D Ex tc IIIC T135°C Dc...
  • Page 21: Standards And Guidelines

    NKK (Nippon Kaiji Kyokai) PRS (Polski Rejestr Statków) RINA (Registro Italiano Navale) Standards and Guidelines 750-1402 I/O modules meet the following requirements on emission and immunity of interference: EMC CE-Emission of interference acc. to EN 61000-6-3: 2007 EMC CE-Immunity to interference acc.
  • Page 22: Mounting

    Don't forget the end module! Always plug an end module 750-600 onto the end of the fieldbus node! You must always use an end module at all fieldbus nodes with the WAGO I/O System 750 fieldbus couplers/controllers to guarantee proper data transfer.
  • Page 23: Inserting And Removing Devices

    WAGO-I/O-SYSTEM 750 Mounting 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Inserting and Removing Devices Use caution when interrupting the PE! Make sure that people or equipment are not placed at risk when removing an I/O module and the associated PE interruption. To prevent interruptions, provide ring feeding of the ground conductor, see section "Grounding/Ground Conductor"...
  • Page 24: Removing The I/O Module

    Mounting WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching With the I/O module snapped in place, the electrical connections for the data contacts and power contacts (if any) to the fieldbus coupler/controller or to the previous or possibly subsequent I/O module are established.
  • Page 25: Connect Devices

    Do not connect more than one conductor at one single connection! If more than one conductor must be routed to one connection, these must be connected in an up-circuit wiring assembly, for example using WAGO feed- through terminals. Exception: If it is unavoidable to jointly connect 2 conductors, then you must use a ferrule to join the wires together.
  • Page 26: Process Image

    Process Image WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Process Image Table 10: Input bits 0 … 7 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 DI 8...
  • Page 27: Accessories

    8-Way Adapter for System Cables, 706-7753/301-xxx with 14-pin flat cable connector, Output, positive switching The following WAGO ribbon cables are available for connecting the interface or relay modules to the 750-1402 I/O Module: Table 14: Series 706 (WAGO ribbon cable)
  • Page 28: Use In Hazardous Environments

    WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Use in Hazardous Environments The WAGO-I/O-SYSTEM 750 (electrical equipment) is designed for use in Zone 2 hazardous areas. The following sections include both the general identification of components (devices) and the installation regulations to be observed. The individual subsections of the "Installation Regulations"...
  • Page 29: Marking Configuration Examples

    WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Marking Configuration Examples 8.1.1 Marking for Europe according to ATEX and IEC-Ex Figure 10: Side marking example for ATEX and IEC Ex approved I/O modules according to CENELEC and IEC Figure 11: Printing Text detail –...
  • Page 30: Figure 12: Side Marking Example For Ex I And Iec Ex I Approved I/O Modules

    Use in Hazardous Environments WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Figure 12: Side marking example for Ex i and IEC Ex i approved I/O modules according to CENELEC and IEC Figure 13: Text detail – Marking example for Ex i and IEC Ex i approved I/O modules according...
  • Page 31: Table 16: Description Of Marking Example For Ex I And Iec Ex I Approved I/O Modules According To Cenelec And Iec

    WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Table 16: Description of marking example for Ex i and IEC Ex i approved I/O modules according to CENELEC and IEC Inscription text Description TÜV 07 ATEX 554086 X Approving authority or TUN 09.0001X...
  • Page 32: Marking For America According To Nec 500

    Use in Hazardous Environments WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching 8.1.2 Marking for America according to NEC 500 Figure 14: Side marking example for I/O modules according to NEC 500 Figure 15: Text detail – Marking example for I/O modules according to NEC 500...
  • Page 33: Installation Regulations

    NFPA 70 National Electrical Code Art. 500 Hazardous Locations ANSI/ISA-RP 12.6-1987 Recommended Practice C22.1 Canadian Electrical Code Notice the following points When using the WAGO-I/O SYSTEM 750 (electrical operation) with Ex approval, the following points are mandatory: Manual Version 1.1.0...
  • Page 34: Special Conditions For Safe Operation Of The Atex And Iec Ex (Acc. Demko 08 Atex 142851X And Iecex Ptb 07.0064)

    I/O modules must be mounted in an enclosure with IP 54 degree of protection at a minimum with the following exceptions: I/O modules 750-440, 750-609 and 750-611 must be installed in an IP 64 minimum enclosure. I/O module 750-540 must be installed in an IP 64 minimum enclosure for 230 V AC applications.
  • Page 35: Special Conditions For Safe Use (Atex Certificate Tüv 07 Atex 554086 X)

    I/II/III (non mains/mains circuits) as defined in EN 60664-1. For the type 750-601 the following shall be considered: Do not remove or replace the fuse when the apparatus is energized. The ambient temperature range is: 0°C ≤ T ≤...
  • Page 36 Use in Hazardous Environments WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching The following warnings shall be placed nearby the unit: Do not remove or replace fuse when energized! If the module is energized do not remove or replace the fuse.
  • Page 37: Special Conditions For Safe Use (Iec-Ex Certificate Tun 09.0001

    I/II/III (non mains/mains circuits) as defined in IEC 60664-1. For the type 750-601 the following shall be considered: Do not remove or replace the fuse when the apparatus is energized. The ambient temperature range is: 0°C ≤ T ≤...
  • Page 38 Use in Hazardous Environments WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching The following warnings shall be placed nearby the unit: Do not remove or replace fuse when energized! If the module is energized do not remove or replace the fuse.
  • Page 39: Ansi/Isa 12.12.01

    WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching 8.2.4 ANSI/ISA 12.12.01 This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only. This equipment is to be fitted within tool-secured enclosures only.
  • Page 40 Use in Hazardous Environments WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching For devices equipped with SD card slots: Insert or remove the SD cards unless the area known to be free of ignitable concentrations of flammable...
  • Page 41: List Of Figures

    WAGO-I/O-SYSTEM 750 List of Figures 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching List of Figures Figure 1: View ....................... 14 Figure 2: Data contacts ..................15 Figure 3: Connections ................... 16 Figure 4: Display elements ..................17 Figure 5: Schematic diagram ................. 18 Figure 6: Insert I/O module ...................
  • Page 42: List Of Tables

    List of Tables WAGO-I/O-SYSTEM 750 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching List of Tables Table 1: Number notation ..................8 Table 2: Font conventions ..................8 Table 3: Caption acc. to figure “View” ..............14 Table 4: Connections ..................... 16 Table 5: Display Elements ..................
  • Page 43 WAGO-I/O-SYSTEM 750 List of Tables 750-1402 16DI 24V DC 3.0ms, ribbon cable, low-side switching Manual Version 1.1.0...
  • Page 44 WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 • D-32385 Minden Hansastraße 27 • D-32423 Minden Phone: +49/5 71/8 87 – 0 Fax: +49/5 71/8 87 – 1 69 E-Mail: info@wago.com Internet: http://www.wago.com...

This manual is also suitable for:

750-1402

Table of Contents