CONVERSION TO LP/PROPANE GAS
Every range is provided with a set of injectors for the various types of gas.
Select the injectors to be replaced according to the "INJECTORS TABLE".
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the
body of each injector.
SETTING THE PRESSURE REGULATOR
The pressure regulator is accessible by removing the bottom drawer; the pressure
regulator is positioned on the rear left side of the range. To remove the drawer proceed
as per figure 2.6a.
To set the pressure regulator:
1. Unscrew the regulator cover;
2. Unscrew the A component, reverse and screw it according to the LP/PROPANE
regulation.
Fig. 2.6a
(fig. 2.6b)
1
4
Pressure
regulator
REGULATOR
COVER
Fig. 2.6b