Download Print this page

M2I TOPRH0700WD-W Hardware Manual

Industrial hmi touch panel

Advertisement

Quick Links

Thank you for using Industrial HMI Touch panel series of M2I corporation.
Please read this manual carefully to know installing, wiring, operating, servicing and inspecting this
equipment.
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Industrial HMI Touch Panel
TOPRH0700WD-W(Wireless)
TOPRH0700WD-W Hardware Manual
M2I Corporation
Hardware Manual
1 / 18

Advertisement

loading
Need help?

Need help?

Do you have a question about the TOPRH0700WD-W and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for M2I TOPRH0700WD-W

  • Page 1 Thank you for using Industrial HMI Touch panel series of M2I corporation. Please read this manual carefully to know installing, wiring, operating, servicing and inspecting this equipment. M2I Corporation 1 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 2: Table Of Contents

    7.4 When a problem occurs with your device ......................16 7.5 Setting System Recovery Mode ..........................16 Chapter 8 Warning Label ..................................17 Chapter 9 Products Label ..................................17 M2I Corporation 2 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 3: Chapter 1 Safety Precaution

    Do not block the vents of the cradle to improve water retention and ventilation. Indoor use only. ■ Operation Precautions Strong shock or force may interfere with operation of the unit. M2I Corporation 3 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 4 Do not connect two input voltage ports at the same time. The cradle is designed to operate at DC voltage. Do not use AC voltage. M2I Corporation 4 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 5: Chapter 2 Overview

    User Options (Rechargeable Auxiliary Battery Pack) Battery Pack USB Memory USB Ext. Cable Accessories (Sold separate) User Options SD Card 전면 보호 Sheet M2I Corporation 5 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 6: Explanation Of Model Name

    Permanent Real Time Clock Built in (by Battery) Environment Specifications Operation Temperature (℃) -10 ~ +45 Storage Temperature (℃) -20 ~ +60 M2I Corporation 6 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 7: Structure Specifications

    Main Body (Including Battery Pack): 1.3, Cradle: 0.6 Cooling System Natural air circulation Case Material PC(Flame Retardant) Chapter 4 Parts Identification and Functions 4.1 Main Body 4.1.1 External Dimension M2I Corporation 7 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 8 SD Card Drawing and Logging Data Up/Download ⑦ USB HOST Connector for USB storage option ⑧ USB Device Drawing and Logging Data Download M2I Corporation 8 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 9 Connect to external device terminal such as PLC and control contact point ② Power Switch Switch for Power On/Off 4.1.6 Keylock switch contact M2I Corporation 9 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 10: Cradle

    Charging after the main battery pack is completely discharged Consumption Charging after the main, Auxiliary battery pack completely discharged 4.2.2 External Dimension (mm) 214.5 M2I Corporation 10 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 11: Chapter 5 Interface

    Frequency Range 2.4G: 2.4000GHz~2.4835GHz, 5G: 5.150GHz~5.725GHz Antenna Type Built in Antenna Security Setting (*AP side Setting) WEP(64/128), WPA-PSK+(TKIP, AES)/WPA2-PSK+(TKIP, AES) *AES Recommend M2I Corporation 11 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 12: Usb Interface

    Lower the Option Pack lock to secure the battery pack. c. the battery pack by lifting the Option Pack lock up. M2I Corporation 12 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 13: Body Mount

    To charge the main battery and the auxiliary battery, the cradle power supply can be powered from the terminal block or the DC plug of the adapter. M2I Corporation 13 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 14: Cradle Ground Wiring

    (2) Grounding should be done with a dedicated ground. It is recommended that the ground is a 3-class ground. (Ground resistance is 100Ω or less) M2I Corporation 14 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 15: Chapter 7 Maintenance

    Are you operating within the specified temperature range (10 ~ 45°C)? b. Are you operating within the specified humidity range (10 ~ 80%RH)? c. Is there any corrosive gas around? M2I Corporation 15 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 16: When A Problem Occurs With Your Device

    Only authorized workers authorized by M2I Corporation can inspect and repair problems related to malfunction of this equipment. c. If the problem cannot be solved at the installation site, the equipment can be collected and moved to M2I Corporation.
  • Page 17: Chapter 8 Warning Label

    I Corporation 2025.02 www.m2i.co.kr - When using M2I equipment, thoroughly read this datasheet and associated manuals introduced in this datasheet, also pay careful attention to safety and handle the module properly. - Store this datasheet in a safe place so that you can take it out read it whenever necessary.
  • Page 18 TOPRH0700WD-W Hardware Manual 2. Battery pack (MODEL: TOPRH-BAT) ---------------------------------------------------------------------------------------------------------------------------- 3. Charging Cradle (MODEL: TOPRH-CRDL) ---------------------------------------------------------------------------------------------------------------------------- M2I Corporation 18 / 18 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...