ZURN plumbSMART HYDRO-X POWER AquaSense ZG6913 Installation, Operation, Maintenance And Parts Manual

Sensor-operated gear driven type faucets with battery powered, hardwired or connected

Advertisement

ZG6913
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the
date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are
notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly
maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages
whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the
defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the
purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantabi-
lity is expressly excluded. If the products sold hereunder are "consumer products," the implied warranty of merchantability is limited to
a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists
are approximate and are not guaranteed.
NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.
AVIS : LIRE L'ENSEMBLE DU MANUEL AVANT D'INSTALLER LE PRODUIT
Rev: C | Date: 07/09/24 | C.N. No. 146057 | Prod./Dwg. No. FV846
Patent zurn.com/patents
US 1.855.ONE.ZURN CANADA 1.877.892.5216
ZURN.COM
AquaSense
ZG6913 & ZG6915
Sensor-Operated Gear Driven Type
Faucets with Battery Powered,
Hardwired or Connected
Installation, Operation, Maintenance
and Parts Manual
LIMITED WARRANTY
Series
®
ZG6915

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the plumbSMART HYDRO-X POWER AquaSense ZG6913 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZURN plumbSMART HYDRO-X POWER AquaSense ZG6913

  • Page 1 NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT. AVIS : LIRE L’ENSEMBLE DU MANUEL AVANT D’INSTALLER LE PRODUIT Rev: C | Date: 07/09/24 | C.N. No. 146057 | Prod./Dwg. No. FV846 Patent zurn.com/patents US 1.855.ONE.ZURN CANADA 1.877.892.5216 ZURN.COM...
  • Page 2: Specifications

    Aerator: 0.5 GPM Vandal-Resistant (Standard) Important Safety Information • Do not convert or modify this Zurn product. All warranties will be voided. • All plumbing is to be installed in accordance with applicable codes and regulations. • Water supply lines must be sized to provide an adequate volume of water for each fixture. • Flush all water lines prior to making connections.
  • Page 3 The following information refers to Zurn Smart Connected Products, types: -W2. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference intended for use in non-residential/non-domestic environments.
  • Page 4: Package Contents

    Package Contents Hydrogenerator Electronics module Batteries ZG6913 ZG6915 Faucet Spout Faucet Spout & Mounting & Mounting Hardware Hardware Connected Monitor Aerator & Key (If ordered) Required Tools Optional Accessories M3 hex Key Wrench Adjustable Wrench (Supplied) -CWB Pigtail P6900-CWB AC/DC Power Supply Magic Magnet P6900-ACA P6900-AT-MAG...
  • Page 5 Cover Plate Installation Instructions (ZG6913 Series) (For ZG6913 faucets with -CP4 or -CP8 suffix). Thread the sensor connector wire and shank through the gasket. Align the gasket with the bottom of the faucet and firmly press them together. Then, pass the sensor connector and shank through the cover plate, securing them to the faucet using the supplied screws. Spout Installation Instructions (All Configurations) NOTE: Before installation, turn off water supplies to existing faucet and remove faucet if replacing an existing device.
  • Page 6 7. Connect sensor cable from electronics module to sensor cable from spout. To customize the following individual electronics module settings, download Zurn plumbPRO App. • Adjustable Time Out Feature • Hygienic Line Flushing • Sensing Mode • Sensor Range Adjustment •...
  • Page 7 Endpoint & Electronic Module Installation Instructions (-ACA/-CWB) Note: The full assembly can be installed vertically with electronics module biased to the left or to the right, or in horizontal orientations with the help of composite filter (see parts list section) to accommodate available space under the sink. 1. Open battery module using supplied Allen wrench and install 2.
  • Page 8 Optional MJ unit (sold separately) Note: Do not connect more than 3 boxes to a single transformer -HW6 F F A A U U C C E E T T F F A A U U C C E E T T B B L L A A C C K K /W /WH H IT ITE E S S T T R R I I P P E E...
  • Page 9 Connected Monitor Installation Instructions (-W2) NOTE: Follow and complete Electronics Module Installation Instruction before continue. 1. Install Connected Monitor on wall surface within 2 feet radius 2. Loosen lid screw with supplied 3mm hex key wrench and open of faucet with dry wall anchors & screws or doubled sided VHB the lid.
  • Page 10 Endpoint & Connected Monitor Installation Instructions (-W2-ACA/-W2-CWB) NOTE: Follow and complete Electronics Module Installation Instruction before continue. 1. Install Connected Monitor on wall surface within 2 feet radius 2. Loosen lid screw with supplied 3mm hex key wrench and open of faucet with dry wall anchors &...
  • Page 11 6b. Optional HW6 (Hardwired 6V) version: Connect inline connector and hardwire adapter. When securing the CWB wires to the screw terminals on HW6 unit, the BLACK WITH DASHED MARKINGS should be connected to the Positive (+) terminal, and the SOLID BLACK wire should be connected to the Negative (-) terminal.
  • Page 12 Mixing Valve Installation (All Configurations) Faucet Control Box -SSH Option P6900-MV-ADAP Braided Hose Supplied Adapter -MV Option Mixing Valve -TMV-1 Option 3/8 Copper Tube Thermostatic (Not Supplied) Mixing Valve Note:To install Braided Hose, need to hold swivel nut on control box or mixing valve in position then apply torque by hand or wrench to install.
  • Page 13 Sensor Range Adjustment (All configurations when necessary) 1. Ensure that the faucet is installed and powered has been applied. 2. Place and hold the Magic Magnet (optional accessory: P6900-AT-MAG) in the upper right hand corner of the sensor as shown. An indicating light will activate when the magnet is correctly positioned.
  • Page 14 Zurn connected product. 3. Drill holes for the screws and insert anchors. 4. Zurn Gateways have been set to DHCP by default. Please 4. Place the mounting bracket and secure it with screws. consult local IT support for possible additional access requirements for your network.
  • Page 15 If the shank, is missing. gasket is not installed, proceed to install it. In case of any damage, replace the gasket with a new one. For further assistance with troubleshooting visit http://www.zurn.com FV846 Rev. C 07/09/24 Page 14...
  • Page 16 Details tab is listed as “Activated” NETWORK: Senet SUBSCRIPTION STATUS: Activated LAST HEARD FROM: 07/14/2020, 04:29 PM CDT If listed as “Deactivated”, contact Zurn Customer Service at 1.855.ONE.ZURN (1.855.663.9876) for assistance. “Status – Good” posted in plumbSMART and faucet not Step 1 actuating Verify LoRa Monitor’s cables are connected to IR sensor...
  • Page 17 If LORA LED does not turn ON solid and ethernet cable connected, contact facility IT administrator to modify port rules to allow Zurn gateway to access the internet via local router. If gateway model is ETH/LTE, visually verify SIM card is installed in designated slot on the side of gateway.
  • Page 18 ZG6913 & ZG6915 Parts List 9 & 10 Description Product No. Description Product No. Item 1: ZG6913 Spout Assembly with Item 11: Mixing Valve with Filter P6900-MV-XL PG6913-1 Sensor Item 12: Composite Mixing Valve Adapter P6900-MV-ADAP Item 2: ZG6915 Spout Assembly with Item 13: Thermostatic Mixing Valve P6900-TMV-1-XL PG6915-1...

This manual is also suitable for:

Plumbsmart hydro-x power aquasense zg6915

Table of Contents