ZURN Cumberland ZG6956 Installation, Operation, Maintenance And Parts Manual

ZURN Cumberland ZG6956 Installation, Operation, Maintenance And Parts Manual

Sensor-operated gear driven type faucets with battery powered, hardwired or connected

Advertisement

ZG6953
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the
date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are
notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly
maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages
whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the
defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the
purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantabil-
ity is expressly excluded. If the products sold hereunder are "consumer products," the implied warranty of merchantability is limited to a
period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are
approximate and are not guaranteed.
NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.
Rev: A | Date: 03/11/24 | C.N. No. 145873 | Prod./Dwg. No. FV851
Patent zurn.com/patents
US 1.855.ONE.ZURN CANADA 1.877.892.5216
ZURN.COM
Serio Series
ZG6953 & ZG6956
Sensor-Operated Gear Driven Type
Faucets with Battery Powered,
Hardwired or Connected
Installation, Operation, Maintenance
and Parts Manual
LIMITED WARRANTY
®
ZG6956

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cumberland ZG6956 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZURN Cumberland ZG6956

  • Page 1 All weights stated in our catalogs and lists are approximate and are not guaranteed. NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT. Rev: A | Date: 03/11/24 | C.N. No. 145873 | Prod./Dwg. No. FV851 Patent zurn.com/patents US 1.855.ONE.ZURN CANADA 1.877.892.5216 ZURN.COM...
  • Page 2: Specifications

    Aerator: 0.5 GPM Vandal-Resistant (Standard) Important Safety Information • Do not convert or modify this Zurn product. All warranties will be voided. • All plumbing is to be installed in accordance with applicable codes and regulations. • Water supply lines must be sized to provide an adequate volume of water for each fixture. • Flush all water lines prior to making connections.
  • Page 3 • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult an authorized dealer or service representative for help. Zurn is not responsible for any radio or television interference caused by using other than specified or recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operate the equipment.
  • Page 4: Package Contents

    Package Contents Hydro Generator Electronic Box Batteries ZG6953 ZG6956 Faucet Body Faucet Body & Mounting & Mounting Hardware Hardware Connected Monitor (If ordeded) Aerator & Key Required Tools 3/32” & M3 Hex Key Wrenches Adjustable Wrench (Supplied) Phillips Head Screwdriver FV851 Rev. A 03/11/24 Page 3...
  • Page 5: Optional Accessories

    Optional Accessories Magic Magnet P6900-AT-MAG AC/DC Power Supply P6900-ACA Cover Plate Installation Instructions Pass the sensor connector and shank through the cover plate, securing them to the faucet using the supplied screws. FV851 Rev.A 03/11/24 Page 4...
  • Page 6 Spout Installation Instruction NOTE: Before installation, turn off water supplies to existing faucet and remove faucet if replacing an existing device. Clean the faucet basin and clear away debris. Flush all supply lines before connecting the faucet. Failure to do so may result in debris clogging the inlets and/or internal control and mixing valve 1.
  • Page 7 Electronics Module Installation Instructions (-HYD) 1. Connect hydrogenerator and electronics module with the swivel 2. Connect electronics module power cable to hydrogenerator. nut turning counter clockwise. Hydro Generator Electronic 3. Open battery module using supplied Allen wrench and install 4. Tighten electronics module assembly with hydrogenerator to supplied alkaline batteries in the electronics module in the shank and connect water line(s).
  • Page 8 Connected Monitor Installation Instructions (-W2) NOTE: Follow and complete Electronics Module Installation instruction before continue. 1. Install Monitor on wall surface within 2 feet radius of faucet with 2. Loosen lid screw with supplied 3mm Allen wrench and Open the dry wall anchors &...
  • Page 9 Mixing Valve Installation (All Configurations) Faucet Control Box -SSH Option P6900-MV-ADAP Braided Hose Supplied Adapter -MV Option Mixing Valve -TMV-1 Option 3/8 Copper Tube Thermostatic (Not Supplied) Mixing Valve Note:To install Braided Hose, need to hold swivel nut on control box or mixing valve in position then apply torque by hand or wrench to install.
  • Page 10 Zurn connected product. 3. Drill holes for the screws and insert anchors. 4. Zurn Gateways have been set to DHCP by default. Please 4. Place the mounting bracket and secure it with screws. consult local IT support for possible additional access requirements for your network.
  • Page 11 If the shank, is missing. gasket is not installed, proceed to install it. In case of any damage, replace the gasket with a new one. For further assistance with troubleshooting visit http://www.zurn.com FV851 Rev.A 03/11/24 Page 10...
  • Page 12 Details tab is listed as “Activated” NETWORK: Senet SUBSCRIPTION STATUS: Activated LAST HEARD FROM: 07/14/2020, 04:29 PM CDT If listed as “Deactivated”, contact Zurn Customer Service at 1.855.ONE.ZURN (1.855.663.9876) for assistance. “Status – Good” posted in plumbSMART and faucet not Step 1 actuating Verify LoRa Monitor’s cables are connected to IR sensor...
  • Page 13 If LORA LED does not turn ON solid and ethernet cable connected, contact facility IT administrator to modify port rules to allow Zurn gateway to access the internet via local router. If gateway model is ETH/LTE, visually verify SIM card is installed in designated slot on the side of gateway.
  • Page 14 ZG6953 & ZG6956 Parts List 9 & 10 Description Product No. Description Product No. Item 1: ZG6956 Spout Assembly with Item 7: 4” Cast Cover Plate w/Gasket P6900-CP4 PG6956-1 Sensor Item 8: 8” Cast Cover Plate w/Gasket P6900-CP8 Item 2: ZG6953 Spout Assembly with Item 9: Single Stainless Supply Hose (XL) P6900-SSH PG6953-1...
  • Page 15 This Page Intentionally Left Blank FV851 Rev.A 03/11/24 Page 14...
  • Page 16 Rev: A | Date: 03/11/24 | C.N. No. 145873 | Prod./Dwg. No. FV851 Patent zurn.com/patents US 1.855.ONE.ZURN CANADA 1.877.892.5216 ZURN.COM...

Table of Contents