IBO MAGI 2 Instruction Manual
IBO MAGI 2 Instruction Manual

IBO MAGI 2 Instruction Manual

Energy-saving circulation pump

Advertisement

Quick Links

Instruction
manual
ENERGY-SAVING CIRCULATION PUMP
MAGI 2
MAGI 2 25-40/180, MAGI 2 25-60/130, MAGI 2 25-60/180,
MAGI 2 25-80/180, MAGI 2 32-80/180
CAUTION! Read the instruction manual before use. For safety
reasons only persons knowing precisely the instruction
19
manual may operate the pump.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAGI 2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IBO MAGI 2

  • Page 1 Instruction manual ENERGY-SAVING CIRCULATION PUMP MAGI 2 MAGI 2 25-40/180, MAGI 2 25-60/130, MAGI 2 25-60/180, MAGI 2 25-80/180, MAGI 2 32-80/180 CAUTION! Read the instruction manual before use. For safety reasons only persons knowing precisely the instruction manual may operate the pump.
  • Page 2: Table Of Contents

    Table of contents Information / symbols used in the manual device Safety of use Inspection Installation Control panel Operating mode selection Dependency between pump settings and its operating parameters Pump start Efficiency curve Technical data and installation dimensions Troubleshooting Utilisation EC declaration of conformity | modul A KARTA GWARANCYJNA Any use of the device, other than the intended use, is a foreseeable misuse of the...
  • Page 3: Information / Symbols Used In The Manual Device

    Information / symbols used in the manual device Warning! “Danger” symbol used for notes whose non-observance may result in danger to life or health caused by the electrical installation. The power cord of the pump must be disconnected from the power supply before carrying out the operations marked with this symbol.
  • Page 4: Safety Of Use

    The information contained in this manual is subject to change without prior notice. To ensure correct and safe use of MAGI 2 pumps and to avoid possible damage to the pump and dangerous situations for users, please read the following instructions carefully before installing and operating the device.
  • Page 5 Safety of use 14. If the pump does not operate for a long time, close the ball valves cutting off the pump and cut off electric power supply. 15. If the electric wire powering the pump is damaged, refer to an authorised servicing team to replace it along with its switch.
  • Page 6: Inspection

    Inspection The series of MAGI 2 circulation pumps is used mainly in water circulation in boiler central heating systems in houses. The MAGI 2 series circulation pump serves best in the following systems: • fixed-temperature heating system with variable flow, •...
  • Page 7: Conditions Of Use

    Conditions of use • Permissible ambient temperature from 0°C to + 40°C. • Maximum permissible relative humidity (RH) 95% • Permissible heating medium temperature +2°C~95°C. To prevent condensation of steam on the control panel and the stator, the temperature of the heating medi- um circulating running through the pump must always be higher than the ambient temperature.
  • Page 8: Installation

    Installation INSTALACJA POMPY In installation, please pay attention to the flow direction of the heating medium. An arrow on the pump body shows the flow direction forced by the pump. That direction must be INSTALACJA INSTALACJA POMPY Przy instalacji proszę zwrócić uwagę na kierunek przepływu czynnika grzewczego. Strzałka na korpusie pompy compliant with the circulation of the medium in the system.
  • Page 9: Electric Connection

    • Pompa cyrkulacyjna serii MAGI 2 nie wymaga zewnętrznej ochrony silnika. Podłączenie elektryczne i ochronę należy • MAGI 2 series circulation pump does not require any external motor guards. • Pompa cyrkulacyjna serii MAGI 2 nie wymaga zewnętrznej ochrony silnika.
  • Page 10: Control Panel

    Control panel Control panel elements Constant speed mode Constatnt speed motor indicator low indicator medium gear – 2 gear –1 Constant speed mode indicator high gear – 3 Auto adaptation mode Power consumption indicator AUTO display (Watt) Operation mode changing Changing mode button button constant speed (40/60)
  • Page 11: Operating Mode Selection

    Operating mode selection Displayed error codes After the power supply is switched on, all of dispays will flesh on after which the pump will enter the last running mode before it is switched off. Pressing the main switch button once changes the mode by the following order: AUTO, LPP, HPP, LCP, HCP, 1, 2, 3 For example, if the pump is operating in CP1 mode, pressing the button...
  • Page 12: Dependency Between Pump Settings And Its Operating Parameters

    Pump start Before starting the pump make sure that the system is filled with liquid (heating medium), the system has been prop- erly vented and the pressure at the pump inlet has reached the minimum inlet pressure Ustawienia pompy Symbol Opis systemu schematu as required.
  • Page 13: Efficiency Curve

    Dependency between pump settings and its operating parameters Pump operating Setting Function parameters curve • The AUTO function controls the pump efficiency automatically in the specified range. From the highest to the • It adjusts the pump efficiency depending on the system size; AUTO lowest curve of (factory...
  • Page 14 Minimum [ ] C Maksimum [ ] C Minimum [ ] C Maksimum [ ] C 0,20, for MAGI 2 25-80/180, 32-80/180 pumps EEI ≤ 0,23, this means that the MAGI 2 pump is an energy-saving pump. Zasilanie elektryczne 1×230V +6%/-10%,50Hz,PE Zasilanie elektryczne 1×230V +6%/-10%,50Hz,PE...
  • Page 15: Technical Data And Installation Dimensions

    Technical data and installation dimensions In order to protect the control panel and the pump stator against water steam condensation, always keep the temperature of the heating medium higher than the ambient temperature. Heating medium temperature [°C] Ambient temperature [°C] Minimum [°C] Maximum [°C] Power supply...
  • Page 16: Troubleshooting

    Troubleshooting ISSUE POSSIBLE CAUSE SOLUTION Tripped installation fuse Check the cause, replace the fuse Overcurrent circuit breaker switched off Start the breaker Pump damaged Replace the pump The pump fails to launch Check if the main voltage is compliant Voltage too low with the supplier’s specification Pump rotor blocked Unlock the rotor...
  • Page 17: Utilisation

    Utilisation The used product is subject to disposal as wastes only in selective waste col- lection systems organised by the Network of Communal Electric and Elec- tronic Waste Collection Centres. The customer is entitled to return the used equipment to the network of the electric equipment distributor, at least for free and directly, if the returned device is of proper type and fulfils the same function as a newly purchased device.
  • Page 18: Ec Declaration Of Conformity | Modul A

    EC Declaration of Conformity | Module A 1. Circulation pumps MAGI 2: 25-40/180, 25-60/180, 25-60/130, 25-80/180, 32-80/180 2. Dambat Jastrzębski S.K.A., Adamów 50, 05-825 GRODZISK MAZOWIECKI, POLAND, e-mail: biuro@dambat.pl 3. This declaration of conformity is issued under the sole responsibility of the manufacturer.
  • Page 19: Karta Gwarancyjna

    WARRANTY CARD The following warranty card is valid only with the original purchase document, i.e. invoice or receipt. In addition, it must be certified by the seller with a signature and stamp. The warranty card without the original purchase document attached is invalid. 1.
  • Page 20 Notes...
  • Page 21 Notes...
  • Page 22 BIURO@DAMBAT.PL BIURO / OFFICE +48 22 721 11 92 dambat.pl SERWIS@DAMBAT.PL SERWIS / SERVICE +48 22 632 86 09...

Table of Contents