Dt detector with digital pir sensor, anti masking protection and under-crawl function with ultrabus interface for intrusion detection systems (12 pages)
EU DECLARATION OF CONFORMITY Hereby, EL.MO. S.p.A. declares that the radio equipment GRIFOX485 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following Internet address: elmospa.com – registrationis quick and easy.
090041032 - GRIFOX485 - TECHNICAL MANUAL 1. GENERAL INFORMATION The GRIFOX485 detector is an advanced high-performance miniaturized dual-technology model designed to be installed indoors/outdoors to provide large spaces with volumetric protection. It can be wall mounted, corner mounted or installed so that it can swivel using the optional accessories.
090041032 - GRIFOX485 - TECHNICAL MANUAL 3. VIEW OF DETECTOR Exploded view of detector with all accessories. CUPSGX sunshield for installation outdoors. SNDSGX swivel mount for mounting Optional extra. at an angle with pan/tilt option. Fastening with side clips. Optional extra.
Page 6
090041032 - GRIFOX485 - TECHNICAL MANUAL • Do not fit sensors so that they are directly next to each other or so that they are aimed directly at each other without enough distance between them: keep them at least 15 m apart.
Page 7
090041032 - GRIFOX485 - TECHNICAL MANUAL Protection against removal from the mounting surface Compliance with EN 50131 regulation grade 3 requires that the device is protected against removal from the mounting surface. Mounting without bracket or joint In case of direct mounting on a wall, only:...
Page 8
090041032 - GRIFOX485 - TECHNICAL MANUAL For installation outdoors, with optional sunshield and swivel mount, refer to the following illustrations, which show what mounting positions are and are not allowed: Outdoors cover walls, with sunshield and corner bracket for mounting at 90° or with...
Page 9
090041032 - GRIFOX485 - TECHNICAL MANUAL 5. COVERAGE DIAGRAM Range: 7 - 4 m Coverage: volumetric, 81° Coverage pattern:18 zones arranged over 4 planes Note: the coverage diagram refers to wall mounting without the corner bracket at a height of 2.1m.
Page 10
090041032 - GRIFOX485 - TECHNICAL MANUAL 6. WIRING View of the board inside: Sequence for removing and refitting the board when wiring the detector. international@elmospa.com elmospa.com...
090041032 - GRIFOX485 - TECHNICAL MANUAL 7. ADDRESS SETTINGS Table 1. Note: the number on the first line indicates coding for VIDOMO, VIDOMO2K control units (up to 64), PREGIO control units, PROXIMA control units; the second line alongside each switch indicates coding for ETR100MG2; the third line alongside each switch indicates coding for ETR128-256-512 G2 and TITANIA series v.5.
Page 12
090041032 - GRIFOX485 - TECHNICAL MANUAL Table 2 Note: the number on the first line alongside the base of each switch indicates coding for ETR128-256-512G2 and TITANIA series v.5. DO NOT EXCEED THE MAXIMUM LIMIT THE CONTROL UNIT CAN HANDLE.
Page 13
090041032 - GRIFOX485 - TECHNICAL MANUAL The detector stores the settings received via serial line from the configuration software. To quickly restore the detector’s factory settings, where you have no connection with the software, proceed as follows: • Disconnect power.
Page 14
090041032 - GRIFOX485 - TECHNICAL MANUAL • Select the “Cable Devices” label from the zones menu and click on the “Open configuration form” button in the “Advanced devices configuration” pane. It is ONLY at this point that the first (basic) configuration menu is displayed: Identification of the detector’s firmware,...
Page 15
090041032 - GRIFOX485 - TECHNICAL MANUAL Oscillograph feature The oscillograph feature is a major plus of the detector’s management software as it allows you to effectively view the environmental noise detected and motion in the area protected by the detector. The display options allow you to select the...
Page 16
These commands are also available during waveform recording, as described further on. 8.3 Alarm event log The GRIFOX485 detector can store locally the waveforms relating to the last alarm triggered. The sensor’s alarm log can be read and viewed only with the aid of the software.
Page 17
090041032 - GRIFOX485 - TECHNICAL MANUAL The detector’s alarm is only logged if at least one of the sectors belonging to the zone relating to the sensor is armed, in which case the following details are stored: • The waveforms of the first alarm received after arming.
Page 18
090041032 - GRIFOX485 - TECHNICAL MANUAL 8.4 Waveform recording function This function allows the detector’s waveforms to be recorded for up to 4 hours. While the unit is recording, engineers can move inside the area protected by the detector and then return to the PC, stopping the recording, saving it and playing it back at their leisure to assess behaviour during operation.
9.5 OR mode The GRIFOX485 detector can be software programmed to set it to OR operating mode. In this mode, the alarm is triggered when either of the two technologies (PIR or microwave) report an alarm due to motion in the area being covered.
Page 20
9.7 Look-down function The GRIFOX485 detector features a circuit that is always active to protect, with 2-axis operation, against any change in orientation detected by an accelerometer sensor. If the GRIFOX485 detector is rotated 5° around its Z-axis or X-axis...