El.Mo ETR512 User Manual

El.Mo ETR512 User Manual

Hardwired/wireless, microprocessor-based intrusion detection panels
Table of Contents

Advertisement

Quick Links

Hardwired/wireless, microprocessor-based
intrusion detection panels
ETR512, ETR256, ETR128
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ETR512 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for El.Mo ETR512

  • Page 1 Hardwired/wireless, microprocessor-based intrusion detection panels ETR512, ETR256, ETR128 USER MANUAL...
  • Page 2 Some products incorporate rechargeable or non rechargeable batteries as emergency power supply. Their wrong connection may damage the product, properties and the operator’s safety (burst and fire). Your dealer: 2 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 3: Generals

    1. GENERALS ETR512, ETR256, and ETR128 control units represent the state of the art within a project designed to en- sure high quality security systems in residential, industrial, bank and post office buildings, allowing also multi- system applications. ETR series control units feature an advanced processing and operating capacity while simplifying end-user operation.
  • Page 4: Control Devices

    I6 or I7 readers can be added to the keypad to support remote control function. 3.2 Remote readers I6 and I7 These readers cannot be used for programming control units, and have to be connected after NADIR keypa- 4 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 5: User Interface

    Second line can be customized with installing company’s name as in the following example: Sa10/04/04 14:34 ACME SECURITY 4.2 LED indicators LED indicators of control keypads defined as system or area terminals. ETR512 - ETR256 - ETR128 - USER MANUAL - 5...
  • Page 6: Operating Status

    COMMON KEYS Zone no. 020 TAMPER ALARM EXIT DISPLAY ZONE XXX MODE BEFORE IT CAN ALSO REFER TO BYPASSED ZONES TIMEOUT BROWSE 5.2 Disarm sectors (partitions) or system from keypad 6 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 7: Arm Sectors (Partitions) Or System From Keypad

    ARMED/DISARMED STATE ACOUSTIC ACOUSTIC SIGNAL CONFIRMATION NOTE: to quickly arm control unit, press twice OK key. 5.4 Disarm system with proximity user key 5.5 Arm system with proximity user key ETR512 - ETR256 - ETR128 - USER MANUAL - 7...
  • Page 8: Arm System From Keypad In "Max Security" Mode

    5.6 Arm system from keypad in "MAX SECURITY" mode 5.7 Disarm from keypad with system armed in "MAX SECURITY" mode 5.7.1 User enabled for "MAX SECURITY" mode 5.7.2 User disabled for "MAX SECURITY" mode Unauthorized action. 8 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 9: Control Mode

    - Present proximity user key to reader sensible area only. - Press key as soon as sector keys (S1- S2 - S3 - S4) start blinking. - Go on with ordinary control steps from keypad. ETR512 - ETR256 - ETR128 - USER MANUAL - 9...
  • Page 10: Bypass Zones From Keypad

    Digit no. or Ok BYPASS ZONES 2 TIMES TO Z. nnn Bypassed Z. nnn Enabled EXIT MENU BROWSE Zone no. zzz Zone no. nnn 3 TIMES TO EXIT CONTROL MODE POSSIBLE DISPLAY MESSAGES 10 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 11: Read Event Log

    5.12 Read event log 5.13 Set day/time ETR512 - ETR256 - ETR128 - USER MANUAL - 11...
  • Page 12: Telephone Dialler: Set Phone Numbers

    ANOMALY SIGNAL FROM INSTALLER DURING TO FIND NON-TESTED DETECTORS TEST FROM TESTED SETUP PROCEDURE DETECTORS COMPLETED DETECTOR NON-Test Detect. MAINTENANCE Vol. entrance TEST ZONES EXAMPLE OF A EXIT NON-TESTED DETECTOR 12 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 13: Outputs Test

    5.17 Telephone dialler test Note: Before proceeding with the dialler test always warn subscriber of the phone number the dialler will call. See “SYSTEM TEST” part on page. 18 for test procedure. ETR512 - ETR256 - ETR128 - USER MANUAL - 13...
  • Page 14: Temporary Day Type Setup

    5.18 Temporary day type setup 5.19 Enable voice and GSM remote interrogation, and remote assistance 14 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 15: Set Standard/Daylight Saving Time

    Remote help function enables phone communication between user and installer (or maintenace man), so that they can communicate during a remote assistance session when installer (or maintenance man) will give user direct instructions to solve possible problems. ETR512 - ETR256 - ETR128 - USER MANUAL - 15...
  • Page 16: Gsm Communication

    5.22 GSM communication 5.23 Overtime management 16 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 17: Menu Diagram

    5.24 Menu diagram Users can enter the following menus: ETR512 - ETR256 - ETR128 - USER MANUAL - 17...
  • Page 18: System Test

    - if specifically asked to do so by the user, - after having explained all consequences of time values modifications, - after having taken full responsability for the operation. Default: 4 weeks, 26 weeks max. 18 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 19: Remote Interrogation

    "PANEL DISARMED, NOT READY FOR ARMING" when control panel sectors are disarmed, and cannot be armed for whatever reasons. "PANEL ARMED TOTALLY" when control panel user-related sectors are armed ETR512 - ETR256 - ETR128 - USER MANUAL - 19...
  • Page 20: Sectors (Partitions) Operating Status

    On the remote phone keypad, acknowledged user has to digit the following code: # 2 * Control panel will return pre-recorded messages with details concerning armed zones status and bypass information: "ZONE ONE TWO ALARM" if zone no.12 is in alarm mode, 20 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 21: Tamper And Intrusion Alarm Memory

    " LOW BATTERY " or " LOW BATTERY MEMORY " " KEYPAD TAMPERING " or " KEYPAD TAMPER MEMORY " " PANEL TAMPERING " or " PANEL TAMPER MEMORY ". ETR512 - ETR256 - ETR128 - USER MANUAL - 21...
  • Page 22: Outputs State

    N stands for outputs number. Control panel will return pre-recorded messages with details concerning selected output NON active state. "OUTPUT ONE NOT ARMED" indicates that output no.1 is NOT active. 22 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 23: Panel Disarm Command

    " ZONE ONE THREE NOT BYPASSED " if zone no.13 is not bypassed, " ZONE ONE THREE UNAUTHORIZED " if zone no.13 cannot be accessed by current user, " ZONE ONE THREE ERROR " if zone no.13 is disconnected. ETR512 - ETR256 - ETR128 - USER MANUAL - 23...
  • Page 24: Zone Bypass Mode

    To exit remote interrogation mode you can also let 60secs elapse from last DTMF command. Panel will beep three times when there are 25secs left for mode automatic exit. If you do not want to exit remote interro- gation menu, just press whatever key. 24 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 25: Remote Interrogation And Control Via Text Messages

    = Control unit report = Zones report R.M = Tamper and alarm memory report = Control unit anomaly report = Outputs report = Bypassed zones report = Partitions (sectors) report ETR512 - ETR256 - ETR128 - USER MANUAL - 25...
  • Page 26: Control Unit Report (Code: R.c)

    Control unit sends text messages to describe all alarmed and tampered user-related zones. " No Zone Alarmed ": message sent in case there are no zones alarmed. Example: User no.1 request for zones report: U.1 C.123456 R.I 26 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 27: Intrusion And Tamper Alarms Memory Report (Code: R.m)

    Control unit sends text messages to describe all active, user-related outputs. " No armed outputs ": message sent in case there are no outputs armed. Example: User no.1 request for output report: U.1 C.123456 R.U ETR512 - ETR256 - ETR128 - USER MANUAL - 27...
  • Page 28: Bypassed Zones Report (Code: R.e)

    I.OFF = Disarm control unit I.ON = Arm control unit = Arm output no. = Disarm output no. = Bypass zone no. = Enable zone no. L.nn = Set MFT no. 28 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 29: Control Unit Disarming Command (Code: I.off)

    " Output Heating not armed " = If output no.56 (Heating) has been deactivated, or it already was. " D.rejected " = When output is disconnected or is not assigned to current user. Example: User no.1 disarming command for output no.56: U.1 C.123456 D.56 ETR512 - ETR256 - ETR128 - USER MANUAL - 29...
  • Page 30: Zone Bypass Command (Code: E.n)

    The control unit will either reply with information, or will not authorize the operation: Example: User no.1 MFT 24 clock command: U.1 C.123456 L.24 " Clock MFT name " control unit message includes installer-assigned MFT name. 30 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 31: Quick Guide To Remote Interrogation

    U.u C.cccccc L.nn for MFT no. clock command It is also possible to store text messages not yet sent in the memory of the phone used (according to phone features). ETR512 - ETR256 - ETR128 - USER MANUAL - 31...
  • Page 32 This page has been intentionally left blank. 32 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 33: Note

    10. NOTE ETR512 - ETR256 - ETR128 - USER MANUAL - 33...
  • Page 34: Note

    11. NOTE 34 - ETR512 - ETR256 - ETR128 - USER MANUAL...
  • Page 35: Table Of Contents

    8.5. Intrusion and tamper alarms memory report (code: R.M) ....... . . 27 ETR512 - ETR256 - ETR128 - USER MANUAL - 35...
  • Page 36 June 2005 Edition 090000289 Product specifications as described above do not bind the manufacturer and may be altered without prior notice. EL.MO. SpA Tel. +39 0499203333 (R.A.) - Fax +39 0499200306 - Tech. Assist. +39 0499200426 - www.elmo.it - info@elmo.it...

This manual is also suitable for:

Etr256Etr128

Table of Contents