El.Mo DT2000485 Technical Manual

Dt detector with digital pir sensor, anti masking protection and under-crawl function with ultrabus interface for intrusion detection systems

Advertisement

Quick Links

Technical manual
DT2000485
DT detector with digital PIR sensor, anti-masking
protection and under-crawl function with
ULTRABUS interface for intrusion detection systems
ULTRABUS
advanced serial bus
1
DESCRIPTION
DT2000485 is a dual-technology (infrared and microwave)
detector.
DT2000485 supports connection to ULTRABUS RS-485 se-
rial line.
The detector includes two sections operating in AND or OR
mode.
Infrared section (IR): digital PIR sensor with temperature
compensation and environmental monitoring, multi-focal
lens with white light protection.
An additional bottom lens is used for the under-crawl
function.
Microwave section (MW): 10.525 GHz DRO planar antenna
(also available as an alternative in the 9.9 GHz version). An-
ti-masking and anti-sneak device.
The two green and blue LEDs show the activities of the IR
and MW section respectively.
The red LEDs (only active in case of tampered sensor or tam-
per button open), show the activity of the serial line, either
receiving or transmitting.
DT2000485 can be programmed using the BrowserOne
software.
For side-by-side mounting, differentiated frequencies can
be used.
An optional swivel mount may be used for wall or corner
installation.
DT2000485 is certified IMQ - Security Systems.
Compatible control unit
VIDOMO2K
PREGIO series
PROXIMA series
®
Addressee for this information:
Firmware version
8.3.3.0 or above
2.3.2.0 or above
1.0.2 or above
User |
Installer
Compatible control unit
ETRxxx G2 series
TITANIA series
2
PCB
1
2
3
4
1
12V power source terminals and RS-485 connection (A, B)
2
MW antenna
3
PIR sensor
4
Dip switch selectors for addressing
5
RS-485 RX, TX communication LEDs (red)
6
IR LED (green)
7
MW LED (blue)
8
Jumper to exclude protection against removal (S3)
9
Tamper button
1 1 1
Firmware version
1.E or above
4.x or above
9
8
7
6
5

Advertisement

loading
Need help?

Need help?

Do you have a question about the DT2000485 and is the answer not in the manual?

Questions and answers

Summary of Contents for El.Mo DT2000485

  • Page 1 Installer DESCRIPTION Compatible control unit Firmware version ETRxxx G2 series 1.E or above DT2000485 is a dual-technology (infrared and microwave) TITANIA series 4.x or above detector. DT2000485 supports connection to ULTRABUS RS-485 se- rial line. The detector includes two sections operating in AND or OR mode.
  • Page 2 TECHNICAL DATA Model DT2000485 Environmental class Model DT2000485 (1) Adjustable via Browser Identification (2) E.I.R.P. Technology IR + MW (3) Peak to peak MW section MW max range Parts supplied Number of integration pulses Screws, inserts, S4 screw and insert for microswitch against...
  • Page 3 Coverage at maximum range: DEVICE MOUNTING Side view • Opening the housing 60° 1.9 3.3 Top view 15 m – unscrew the cover fixing screw (A) – separate the front cover by pulling it away from the stops 95° • Removing the electronic board 81°...
  • Page 4 I that closes the detector angle. Proceed as follows (images show the internal view of the detector base): Terminal board DT2000485 Previous device over serial line Next device over serial line Use cables with the following section: 2 × 0.75 mm (power) + 2 ×...
  • Page 5 VIDOMO, PREGIO, PROXIMA control units Add. dip ON Add. dip ON Add. dip ON 1 2 3 4 5 6 7 8 - 2 - 4 - 6 - 8 1 - 3 - 5 - 7 - - 2 3 4 5 6 7 8 1 - - 4 - 6 - 8 - - 3 - 5 - 7 - 1 - 3 4 5 6 7 8...
  • Page 6 ETR100MG2 control units Add. dip ON Add. dip ON Add. dip ON - - - - 5 - 7 8 1 2 - 4 5 6 7 - - 2 3 - - 6 - - Add. dip ON Add. dip ON Add.
  • Page 7 ETR128-256-512 G2 and TITANIA series control units Add. dip ON Add. dip ON Add. dip ON - - - - 5 - 7 8 1 2 - 4 5 6 7 - - 2 3 - - 6 - - Add.
  • Page 8 for VIDOMO, PREGIO, PROXIMA control units: Detect noise – click on Cable devices tab It opens an environment noise detection tool for IR and MW – select Zone Type in Sensor 485 drop-down menu sections. After the detection, the tool provides a result ac- –...
  • Page 9 the detection, the technology in pre-alarm status will reset. Playback Play a previously recorded video Restart live acquisition Continue recording after having OR mode pressed STOP. The function can be activated via browser. The alarm relay is activated when either of the two technol- Select Save samples to save a recording.
  • Page 10 Condition Green LED Blue LED Pre-alarm IR ON steady Pre-alarm MW ON steady General alarm ON 5 s ON 5 s Fault, low battery Blinking alternate Blinking alternate to blue to green PIR fault Fast blinking Masking Slow blinking Sneak Fast blinking MAINTENANCE Periodic test Carry out a simple test regularly to verify the functionality...
  • Page 12 The information and product features herein are not binding and may be changed without prior notice. EL.MO. Spa | Via Pontarola, 70 | 35011 Campodarsego (PD) - Italy Ph. +39 049.9203333 | Fax +39 049.9200306 | Help Desk +39 049.9200426 | www.elmospa.com | international@elmospa.com...