DESCRIPTION
TRES01 is a triple-technology detector.
The device features two sections working in AND mode.
Infrared section (IR): 2 digital PIR sensors with temperature
compensation and lens with white light protection.
Microwave section (MW): 10,525 GHz DRO planar antenna.
For side-by-side mounting, differentiated frequencies can
be used.
The device features the function against disorientation, and
also anti-blinding, anti-masking, anti-sneak functions.
LEDs indicate device working activity.
TRES01 can be set with board dip switch.
Optional joint available.
TRES01 is certified IMQ - Security Systems.
Addressee for this information:
User |
Installer
2
PCB
2
1
1
Dip switches
2
PIR sensors
3
Tamper button
4
Terminal board
5
Jumper to exclude protection against removal
6
MW antenna
7
Blue LED
8
Red LED
9
Green LED
1 1 1
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRES01 and is the answer not in the manual?

Questions and answers

Summary of Contents for El.Mo TRES01

  • Page 1 The device features the function against disorientation, and also anti-blinding, anti-masking, anti-sneak functions. LEDs indicate device working activity. TRES01 can be set with board dip switch. Optional joint available. TRES01 is certified IMQ - Security Systems. Dip switches...
  • Page 2: Technical Data

    Choose installation position taking into account coverage Protection class IP3X ranges shown in the following diagrams. IMQ certified EN50131-2-4: TRES01 is IMQ certified with TRL15 standard lens. grade 3 Environmental class • Standard lens TRL15 Dimensions and weight W65 × H111 × D48 Diagrams refer to detectors mounted at 2.1m height.
  • Page 3 Maximum range diagram Minimum range diagram Scale Top view Side view Scale • Optional lens TRLTO Diagrams refer to detectors mounted at 1.5m height. Set detector height according to protection to realise. Range: 15 metres Coverage: aperture 88° Beams arrangement: horizontal curtain Top view Maximum range diagram Side view...
  • Page 4: Device Mounting

    sensors working in AND mode. For details on PIR sensors diagrams positioning see details on the standard lens. Creep zone coverage is active with the use of TRLTO lens too. DEVICE MOUNTING • Opening the housing – using a screwdriver, open the 4 pre-drilled areas of the support suitable for flat mount (F) or corner (G) mount –...
  • Page 5: Protection Against Removal For Corner Mount

    Dual-balancing drawing: • Closing the housing DETECTOR ESCL – position the front cover on the base making sure the tam- CONTROL UNIT per protection spring fits correctly to its place The wrong housing closing will trigger a tamper alarm for all supervision transmissions. –...
  • Page 6: Lens Replacement

    • Lens positioning You can close the gap where the lever was before using the second plastic plug provided. – place the lens with the rough side towards the internal side of the cover and placing it in place with the largest 5.2 Lens replacement number of sectors face up To replace the lens, follow this procedure.
  • Page 7: Starting The Device

    ▼ AND/OR Anti-blinding function DIP 5 Mode TRES01 features anti-blinding function. AND (default) The function detects blinding attempts made by placing a reflective body before the lens. Use dip switches 2 and 3 to activate the function.
  • Page 8: Anti-Sneak

    Fast blinking Slow blinking Slow blinking 7.5 Function against disorientation PIR 1 fault Fast blinking TRES01 features the function against disorientation. PIR 2 fault Fast blinking An accelerometric sensor with operation on two axes de- MW fault Fast blinking tects device moving attempts.
  • Page 9: Maintenance

    MAINTENANCE Periodic test Carry out a simple test regularly to verify the functionality and the coverage limits of the detector. – taking detector position as the point of reference, make half-circle movements from opposite directions to check coverage from both sides Detector LED indicators shall respond as shown in the table of 7.7 ...
  • Page 10: Table Of Contents

    Table of contents DESCRIPTION......P. 1 PCB ........P. 1 TECHNICAL DATA.
  • Page 12: Eu Declaration Of Conformity

    The information and product features herein are not binding and may be changed without prior notice. EL.MO. Spa - Via Pontarola, 70 - 35011 Campodarsego (PD) - Italy Ph. +39 049.9203333 - Fax +39 049.9200306 - Help Desk +39 049.9200426 - www.elmospa.com - international@elmospa.com...

Table of Contents