Compaq CL380 - ProLiant - 256 MB RAM Software User's Manual page 87

Compaq proliant cl380 software user guide
Hide thumbs Also See for CL380 - ProLiant - 256 MB RAM:
Table of Contents

Advertisement

If you are upgrading controller firmware under Novell NetWare 4.2 or
NetWare 5.1, follow the steps in the section titled "Novell NetWare
Firmware Upgrade Procedures."
IMPORTANT: Microsoft Cluster Server under Windows NT Server 4.0, Enterprise Edition,
Cluster Service under Windows 2000 Advanced Server, SNMP service, and any I/O must
be stopped during the firmware update.
8. Restore the controller configuration settings saved in Step 1 using the
Restore Configuration option of the CR3500 Configuration Utility.
9. Power down the shared storage area.
10. Remove the CR3500 RAID Controller blanking panel from
bay 2 (bottom).
11. Insert the original CR3500 RAID Controller into bay 2 (bottom).
12. Power up the shared storage area and verify proper installation and
operation.
NOTE: For more information on the Shared Storage RAID Controller CR3500 LED
diagnostic checks, refer to the Compaq ProLiant CL380 User Guide.
NOTE: After the controllers initialize, the shared storage subsystem will be running in a
redundant controller configuration.
Novell NetWare Firmware Upgrade Procedures
Use the following procedures to upgrade firmware under Novell NetWare 4.2
or NetWare 5.1. Due to the use of a serial interface for firmware updates, this
procedure must be used for each controller as needed.
1. Connect the controller to a system running Microsoft Windows 95, 98,
or NT by means of the serial connector on the back of the shared storage
subsystem.
2. Use a terminal program, such as HyperTerminal, to connect to the host
system.
CR3500 Configuration Utility 4-35

Advertisement

Table of Contents
loading