4-36 Compaq ProLiant CL380 Software User Guide
3. Use the following settings to connect:
G
Bits per second=9600
G
Data bits=8
G
Parity=None
G
Stop bits=1
G
Flow control=Xon/Xoff
4. Power up the shared storage area and press Ctrl+C to abort the
controller boot process.
5. Select option 2 to change the baud rate.
6. Select option 3 to set the baud rate to 38400.
7. Change the baud rate on the terminal to match the controller's baud rate
of 38400.
8. Disconnect and reconnect the terminal service.
9. Press Enter to establish communication with the controller.
10. Select option 1 and press Enter.
11. Transfer the firmware file as a text file from the terminal service. The
entire update should take about 15 minutes at a 38400 baud rate.
12. After the firmware update is complete, select option 2 and change the
baud rate to 9600 by selecting option 1.
13. Change the baud rate to 9600 on the terminal service.
14. Disconnect and reconnect the terminal service.
15. Press Enter to establish communication with the controller.
16. Select option 9 to restart the controller.