Download Print this page

Full Gauge Controls Microsol BMP Advanced WiFi connect Manual page 4

Differential thermostat for solar heating

Advertisement

EVNT
EV.01 STRT
(2s)
EXIT
EV.16
8. SETTINGS - TECHNICAL LEVEL
Access the installation menu by pressing the
SET
Then press the
key again (short press). Use the   and
access code 231, and when ready press the
Use the   or
keys to select the desired function. With a short press on the
possible to edit its value. Use the   or
SET
short press on the
key to memorize the set value and return to the functions menu. To
exit the setup menu and return to normal operation, press the
8.1 PARAMETERS TABLE
TECHNICAL
FUN
DESCRIPTION
CODE Access code
TC.01 Controller language
TC.02 Temperature unit
TC.03 Fluid type
TC.04 Estimated pump flow
TC.05 Flow unit (volume)
TC.06 Power unit
STOP
(2s)
DAYS
ENAB
A1
A2
SET
key for 4 seconds until CODE appears.
keys to enter the value of the
SET
key (short press).
SET
keys to change the value and, when ready, give a
SET
key (long short).
CELSIUS (FAHRENHEIT)
MIN.
MAX.
UNIT DEFAULT
0
9999
-
-
PORT
ENG
PORT
-
°C
°F
WATE
GLYC
-
WATE
1
999
l/m
LITER
GALL
-
LITER
-
kWh
MBTU
(hour)
(hour)
(yes)
SUN
MON
SUN
MON
(no)
YES NO
OFF SP ECO
OFF SP ECO
Events 1 and 2 are previously configured with schedules and control parameters as follows:
STRT
STOP
DAYS
EVNT
AUX1
AUX2
8.2 DESCRIPTION OF PARAMETERS
CODE - Access code:
Is is necessary when you want to change the configuration parameters. To only visualize the
adjusted parameters it is not necessary to insert this code.
Code 231 - Technician
key it is
TC.01 - Controller language:
Selects the language for displaying messages on the controller:
PORT = Portuguese;
TC.02 - Temperature Unit:
Selects the controller temperature unit:
°C = Celsius;
0
Note:
When the unit is changed, the controller goes into pause mode and
°C
reconfigures the parameters for the new unit, restarting the operation soon after.
50
TC.03 - Type of fluid:
kWh
Informs the type of fluid used in the collector. Information udes to estimate the amount of
energy absorbed by the solar heating system:
WATE = water;
TC.04 - Estimated pump flow:
Informs the estimated flow rate of the pump. Information used to estimate the amount of
energy absorbed by the solar heating system.
TC.05 - Flow unit (volume):
Defines the desired flow unit to display the estimated energy absorbed by the solar heating
system.
TC.06 - Power unit:
Selects the desired energy unit to display the estimated energy absorbed by the solar
heating system.
(minutes)
(minutes)
(TUE - WED - THU - FRI)
(yes)
(no)
SAB SUN
Sunday
MON
SAB
Monday
SEG
SAB TUE
Tuesday
SAB WED
Wednesday
SAB THU
Thursday
SAB FRI
Friday
SAB SAT
Saturday
EVENT 1
EVENT 2
06:00
17:00
09:00
22:00
Monday to Sunday
Monday to Sunday
ENABLED
ENABLED
SP
SP
Code 123 - Advanced
ESP = Spanish;
ENG = English.
°F = Fahrenheit.
GLYC = propylene glycol solution.
(yes)
SAT
SAT
(no)
SP
SP

Advertisement

loading
Need help?

Need help?

Do you have a question about the Microsol BMP Advanced WiFi connect and is the answer not in the manual?