1. DESCRIPTION
The Microsol RST Advanced
control logic for heating and cooling. It has a clock, event schedule for rational and
economical use of the controlled load, as well as protection for accessing configuration
parameters.
The Microsol Advanced
transfer technology for configuring and diagnosing your heating system through the
exclusive Microsol
It is characterized by a unique design for use in residential environments, by the ease of
operation with touch keys for easy access to the main features of the controller and by the
use of a customized display.
2. APPLICATION
- Solar heating with auxiliary heating system.
3. TECHNICAL SPECIFICATIONS
Power
Consumption
Operating temperature
Operating humidity
Sensors
Control temperature
0.1°C between -10 and 100°C and 1°C in the rest of the range
Resolution
0.1°F between -10 and 100°F and 1°F in the rest of the range
Control output
Digital input
Dimensions
4. INTENDED USE
4.1 INTERFACE
1
1.
Display
2.
Auxiliary 1 Indication
3.
NFC area
4.
Auxiliary 1 key
3
5.
Increase key
6.
Decrease key
7.
SET key
4.2 OUTPUT INDICATION
Each controller output has a colored LED to indicate the state and output mode. The color
of the LED indicates the mode selected for the output. The flashing led indicates that the
output is on.
Output status of LEDs:
• Off = OFF
• Green = Automatic (AUT)
• Yellow= Manual (MAN)
• Yellow/White= Manual in WEEKEND mode
5. NFC FUNCTIONALITY
NFC is a technology for data exchange and wireless communication. Perform controller
setup and verify your data using the Microsol
compatible smartphone. For more information, visit the website:
http://microsolconnect.fullgauge.com/ or scan the QRcode with your cell phone.
1 - Bring the cell phone closer to the highlighted NFC position, as shown in image (1). With
the cell phone close to it, the controller will beep, signaling that the cell phone has been
detected by the controller.
2 - Keep your cell phone close to initiate communication.
1
2
RST
Advanced
is a digital thermostat with
line has NFC approximation data
app.
115Vac ±10%(50/60Hz) or 230Vac ±10%(50/60Hz)
0 to 50°C (32 to 122°F)
10 a 90% UR (without condensation)
T1: Thermostat – Sensor SB19, 2,5m
Sensor T1: -20 to 105ºC / -4 to 221ºF
AUX 1 - Relay output, max. 16A, 3500W resistor at 220Vac
(1750W at 127Vac)
Configurable dry contact type
104 x 160 x 34mm (4.09" x 6.30" x 1.34")
5
2
4
6
app with a
3
DIGITAL THERMOSTAT
Note: Check the position of the NFC antenna on your cell phone. Using images (2) and
(3) as a reference, it is possible to improve performance by bringing the cell phone
antenna closer to the highlighted position. The correct approximation with the
highlighted NFC position on the controller contributes to an easy and practical use.
Attention! Check your smartphone's compatibility with NFC technology.
6. OPERATIONS
6.1 KEYMAP
3.3VA
Short press - Access user settings.
Long press (4 seconds) - Access advanced settings.
Short press - Checks the status of the function lock.
Long press (4 seconds) - Enables/Disables Function Lock.
See chapter 6.3 Function lock.
Short press - Toggles the temperature display (T1, TIME). Shows time
remaining when in manual mode.
Long press (4 seconds)
Short press - Changes auxiliary 1 mode (AUT/MAN/OFF).
Long press (4 seconds) - Enables/Disables Weekend mode on
auxiliary 1.
6.2 AUXILIARY OPERATION MODE
Each short press on the auxiliary key A1 changes the operating mode of the support
output between OFF, AUTO and MANUAL modes. By pressing auxiliary key A1 for 4
seconds, MANUAL is set to WEEKEND mode.
OFF
7
Short press
AUT
Short press
MAN
OFF / AUT / MAN
Press for
4 seconds
MANUAL in
WEEKEND mode
Note: When Manual mode is selected, the backup output remains in this state for the
period defined in this mode for the time defined in A1.08 - Auxiliary 1 manual
activation time. The manual mode is used when you want to eventually heat the thermal
reservoir outside the times specified in the event schedule.
6.3 FUNCTION LOCK
For security reasons and in order to prevent unauthorized persons from changing the
controller settings, there is a function lock feature. With this setting activated, the
parameters cannot be changed, only viewed, according to the configured protection
level. Parameter GE.05 determines which type of locking will be performed. In the lock
condition, when trying to change the value of a locked parameter, the
appears on the display. To enable/disable the functions lock, the
for the time configured in parameter GE.06 - Time for locking functions.
Ver. 03
Indicates the approach of the smartphonecompatible with NFC
technology. At this point, communication between the controller
and the smartphone will be initiated.
Indicates the sending of new parameters to the controller.
Indicates updating of data saved in the controller's
NFC memory.
- Inhibits audible alarm.
OFF: Auxiliary output off.
AUT: Support in automatic mode, operating
according to the configuration of the event
schedule and sensor temperature
configured in parameter A1.02.
Short press
MAN: Support in manual mode, remains in
this mode for the time defined in A1.08 -
Time of manual activation of the auxiliary.
Afterwards, it returns to automatic mode. If
A1.08 = OFF, it remains in manual mode
until reaching the Setpoint, after which it
returns to automatic mode.
WEEKEND: Support operates in Manual
mode disregarding the time defined in
A1.08. This parameter has a time limit of
3 days, after this period it returns to
automatic mode.
message11111111
key must be pressed

Advertisement

loading

Summary of Contents for Full Gauge Controls Microsol RST Advanced c-o-n-n-e-c-t

  • Page 1 DIGITAL THERMOSTAT Advanced Ver. 03 Tenha este manual na palma da Have this manual in the palm of your hand through the FG Finder. sua mão pelo aplicativo FG Finder. Note: Check the position of the NFC antenna on your cell phone. Using images (2) and 1.
  • Page 2 Nota: With the function lock active, unauthorized persons will not be able to change the 7. SETTINGS - USER LEVEL operating mode or parameters of the controller. When there is a need for any changes, Access the settings menu by pressing the SET key (short press). Use the just keep pressed the key to enable/disable this feature.
  • Page 3: Parameters Table

    Events 1 and 2 are previously configured with schedules and control parameters as 8. SETTINGS - TECHNICAL LEVEL follows: Access the installation settings menu by pressing the SET key for 4 seconds until CODE Event 1 Event 2 appears. Then press the SET key again (short press). Use the keys to enter the value of the access code 231, and when ready press the SET key again (short STRT...
  • Page 4 IN.02 - Digital input operating mode: 9.2 DESCRIPTION OF PARAMETERS Defines the digital input operating mode: CODE - Access code: OFF = Digital input disabled; It is necessary when you want to change the configuration parameters. To only visualize 1 = Enables/disables auxiliary 1 MAN (manual) mode; the adjusted parameters it is not necessary to insert this code.
  • Page 5: Installation

    For direct activation, take into account A1 and A2 are the contactor the specified maximum current. coil terminals. Full Gauge Controls offers suppressors for sale 11.3 OVERLAY INSTALLATION Route the cables through the openings as per the controller connections. Remove the protective cover from the connections Fix the controller in the 4x2 box with screws.
  • Page 6 After this year with resellers, the guarantee will continue to be valid if the instrument is sent directly to Full Gauge Controls. The products are guaranteed in case of manufacturing failure that makes them unsuitable or improper for the applications for which they are intended.