Full Gauge Controls Microsol BMP Advanced Manual

Full Gauge Controls Microsol BMP Advanced Manual

Solar heating differential thermostat

Advertisement

Quick Links

1.DESCRIPTION
The Microsol BMP Advanced
three sensors and two outputs, which operate in the water circulation pump control and in
thermal support. It is equipped with a clock and an event schedule for economic and
rational use of the thermal support, as well as the exclusive Vacation* function that adds
protection and energy saving to the solar heating system in low hot water consumption
periods.
The controller has functions that avoid overheating and the freezing of the water in the
solar collector. It's equipped with access protection to the parameters settings.
The Microsol Advanced
line is characterized by its unique design for use in
residential environments, by the easiness of operation with keys for easy access to the
controller's main resources and by the use of the custom display. The display technology
employed allows presenting in a complete and simple manner the solar heating system's
information, such as: output status, pump operation mode, and sensor position and
temperature.
*required patent
2. APPLICATION
Solar heating with auxiliary heating system
-
3. TECHNICAL SPECIFICATIONS
- Power:
Microsol BMP Advanced:
±10%(50/60Hz)
- Operation temperature: 0 to 40ºC
- Operation humidity: 10 to 90% UR (without condensation)
- Sensors: The
Microsol BMP Advanced
Sensor T1: Solar Collector – SB59 Sensor, metal tip, Silicone, 1m
Sensor T2: Thermal reservoir – SB41 Sensor, plastic tip, 2m
Sensor T3: Support – SB41 Sensor, plastic tip, 2m
- Control temperature: Sensor T1: -50 to 200ºC / -58 to 392ºF
Sensor T2: -50 to 105ºC / -58 to 221ºF
Sensor T3: -50 to 105ºC / -58 to 221ºF
- Resolution: 0.1ºC between -10 and 100ºC and 1ºC in the remainder of the range
1ºF in all of the range
- Control output: The
Microsol BMP Advanced
PUMP - Relay output, max. 1HP in 220Vca (½ HP in 127 Vca)
AUX - Relay output, max. 16A, resistance
3500W in 220Vca (1750W in 127 Vca)
- Dimensions: 104 x 148 x 32 mm
- Display: LCD 2.75'' with backlight
4. INDICATIONS AND SCREEN
4.1 PRESENTATION
9
1
off
MAX
2
AUX
3
10
Pump mode key
1
Support mode key
2
Clock key
3
Lowering key
4
Set key
5
Increasing key
6
Indication of the pump operation mode
7
Indication of the operation support mode
8
Controller signals
9
Representation of the solar heating system
10
Lower display numbers
11
Upper display numbers
12
4.2 INDICATIONS
SET
In programming, cleared parameter setting
LOC
In programming, blocked parameter setting
Fahrenheit scale temperature Indication
Celsius scale temperature Indication
Pump turned on due to cooling function
Pump turned on due to antifreeze function
Pump turned on due to vacuum tube function
Pump turned on due to temperature differential (T1-T2)
Pump outlet turned on
BMP
Advanced
is a differential thermostat for solar heating with
230Vac ±10%(50/60Hz) or version 115Vac
has 3 sensors:
has two relay outputs:
Obs: the sum of the
loads should not
surpass 24A
8
7
6
AUX
PUMP
off
AUT
MAN
AUT
MAN
12
SET LOC
5
SET
am pm
am pm
4
11
SOLAR HEATING
DIFFERENTIAL THERMOSTAT
Ver. 02
AUX
Support outlet turned on
AUX
Support outlet turned on due to function F21
+
T1 Sensor Position - solar collector
T2 Sensor Position - thermal reservoir
T3 Sensor Position - support
Indicates overheating occurrence T1
MAX
+
Indicates overheating occurrence T2
MAX
+
Indicates that the maximum differential (T1-T2) for protection against
MAX
+
+
thermal shock in the vacuum tube function has been exceeded.
Indicates sensor error occurrence T1
+
Indicates sensor error occurrence T2
+
Indicates sensor error occurrence T3
+
Function block setting
am
Before noon (standard clock 12pm)
pm
After noon (standard clock 12pm)
5. OPERATIONS FOR DOMESTIC USER
5.1 KEY MAP
The controller has easy-access to user resources. Contains table with description of the following:
Short touch: support heating temperature set
SET
Long touch (4 seconds): access to advanced settings
SET
Long touch (see F25 parameter): enables/disables function block
Short touch: switches temperature display (DIF, T1, T2, T3) for 10 seconds
Short touch: switches pump mode (AUT / MAN)
Long touch (4 seconds): switch off pump (OFF mode)
Short touch: switches way support mode (AUT / MAN)
Long touch (4 seconds): enables/disables Vacation support mode (OFF)
Short touch: accesses hour and day settings menu
L ong touch: (4 seconds): accesses settings menu for event schedule
5.2 SUPPORT HEATING TEMPERATURE (SENSOR T3)
Defines the support operation temperature (T3).
SET
To set this parameter, give a short touch on key SET . Use keys
confirm give a short touch on key SET and the value will be saved in the controller
memory. This parameter can be adjusted between the values defined in the advanced
settings for the parameters:[,F17]- Minimum value for the support temperature and
[,F18]- Maximum value for support temperature.
Note: When the T3 sensor is deactivated in [,f24], the support is controlled by the T2
sensor.
5.3 WATER PUMP OPERATION MODE
For every touch on key
the water pump operation mode is switched. The water
circulation pump between the solar collector and the thermal reservoir can operate in three
distinct modes. A description follows:
AUT = Circulation pump in automatic mode
PUMP
AUT
operating according to parameter settings
Quick touch
MAN = Circulation pump turned on
PUMP
Attention: In this mode the pump is maintained turned on ,
MAN
Quick touch
ignoring the protection functions and temperature sensors.
PUMP
OFF = Circulation pump always turned off
off
4 seconds
Obs.: In the pump mode settings, the controller takes on the new mode 5 seconds after its
selection. This also is the time necessary for the parameter to be stored in its memory.
When the MAN mode is selected (MANUAL), the operation mode remains in this state for the
period defined in function [,F09] - Maximum pump time turned in manual mode. After, the
controller takes on the AUT mode (AUTOMATIC). If you wish to return to AUT mode before this
period, press the
key at any time.
5.4 SUPPORT OPERATION MODE
On every short touch on the
key it is possible to change the support outlet operation
mode between MAN and AUT modes.
AUT = Support in automatic mode, operating
AUX
according to the event schedule settings
AUT
T3 sensor temperature (parameter [temp]).
MAN = Support in manual mode, remains in this
mode for the time defined in [,F19] - Time of
AUX
MAN
Manual support activation, after which it returns
to AUT mode.
or
to set value. To

Advertisement

loading

Summary of Contents for Full Gauge Controls Microsol BMP Advanced

  • Page 1 Support outlet turned on due to function F21 is a differential thermostat for solar heating with The Microsol BMP Advanced three sensors and two outputs, which operate in the water circulation pump control and in T1 Sensor Position - solar collector thermal support.
  • Page 2: Vacation Mode

    Obs.: In the support mode settings, the controller takes on the new mode 5 seconds after According to the set operation mode, the following programming possibilities may be its selection. This also is the time necessary for the parameter to be stored in its memory. presented: The manual mode is used when one wishes to occasionally heat the thermal reservoir out Programmed case [,F20] = [,1B1]...
  • Page 3: Parameter Description

    To leave the menu and return to normal operation (temperature indication) hold the SET - If the 123 code has not been inserted, upon accessing the parameter settings key (long touch) until [----] appears. icon will be displayed over the upper display, indicating that the setting is locked.
  • Page 4: Installation

    5.8 – Function Block. To disable this function move the setting to the minimum until it is displayed [,,No]. Suppressors on offer from Full Gauge Controls [,F26]- Display backlight Intensity (Backlight): If the value adjusted in this function is the minimum [,ECO], the intensity of the backlight of the display 8.3 SUPERIMPOSED INSTALLATION...
  • Page 5: Environmental Information

    Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) Secure the controller in yearwarranty, as of the date of the consigned sale, as stated on the invoice. They are...