The Microsol RST Advanced is a digital thermostat with control logic for
heating or cooling. The unit is equipped with a clock, events schedule for rational and
economical use of the controlled load, and protected access to configuration parameters.
It features the Holiday function which saves on power consumption during periods when
the system is idle.
The Microsol Advanced line is characterized by its unique design for use in
residential environments, by the easiness of operation with keys for easy access to the
controller's main resources and by the use of the custom display. The display technology
employed allows presenting in a complete and simple manner the solar heating system's
information, such as: output status, thermostat operation mode, sensor temperature and
time.
2. APPLICATION
- Heating systems for thermal reservoirs
- Floor heating
- Air conditioning
3. TECHNICAL SPECIFICATIONS
- Power: Microsol
RST Advanced:
+-10%(50/60Hz)
- Operation temperature: 0 to 40ºC
- Operation humidity: 10 to 90% UR (without condensation)
- Sensors: The Microsol
RST Advanced
Sensor T1: Thermostat - SB41 Sensor, plastic tip, 2m
- Control temperature: Sensor T1: -50 to 105ºC / -58 to 221ºF
- Resolution: 0.1ºC between -10 and 100ºC and 1ºC in the remainder of the range
1ºF in all of the range
- Control output: The Microsol
RST Advanced has one relay output
AUX - Relay output, max. 16A, resistance
3500W in 220Vca (1750W in 127 Vca)
- Dimensions: 104 x 148 x 32 mm
- Display: LCD 2.75'' with backlight
4. INDICATIONS AND SCREEN
4.1 PRESENTATION
8
1
off
A
2
AUX
3
9
1
Schedule key
2
Thermostat mode key
3
Clock key
4
Lowering key
5
Set key
6
Increasing key
7
Indication of the thermostat operation mode
8
Controller signals
9
Representation of the solar heating system
Lower display numbers
10
11
Upper display numbers
RST
Advanced
230Vac +-10%(50/60Hz) or version 115Vac
has 1 sensor:
:
7
AUX
AUT
MAN
11
SET LOC
SET
am pm
am pm
10
DIGITAL THERMOSTAT
WITH EVENTS SCHEDULE
Ver. 02
4.2 INDICATIONS
SET
In programming, cleared parameter setting
LOC
In programming, blocked parameter setting
Fahrenheit scale temperature Indication
Celsius scale temperature Indication
Thermostat output on, if F01=Cool
AUX
Thermostat output on, if F01=Heat
Indicates the occurrence of a controller error
Function block setting
am
Before noon (standard clock 12pm)
pm
After noon (standard clock 12pm)
5. OPERATIONS FOR DOMESTIC USER
5.1 KEY MAP
The controller has easy-access to user resources. Contains table with description of the
following:
Short key press: set the thermostat temperature
SET
Long touch (4 seconds): access to advanced settings
SET
Long touch (see F10 parameter): enables/disables function block
Short key press: access the menu to set the events schedule
A
Short touch: switches way thermostat mode (AUT / MAN)
A
Long key press (4 seconds): enables/disables thermostat Holiday mode (OFF)
Short touch: accesses hour and day settings menu
5.2 THERMOSTAT TEMPERATURE
Sets the operating temperature of the thermostat.
SET
To adjust this parameter, short press the SET button. Use the
adjust the value. To confirm, short press the SET button and the value will be
saved in the controller memory. This parameter can be adjusted between the
values defined in the advanced configuration for parameters: [,F03] –
Minimum value of the thermostat temperature and [,F04] – Maximum value
of the thermostat temperature.
5.3 THERMOSTAT OPERATING MODE
With each short press of the
thermostat output between AUT and MAN modes.
6
AUX
AUT
AUX
5
4
Note: When adjusting the thermostat mode, the controller changes into the new mode 5
seconds after your selection. This is also the time required for the parameter to be stored in
its memory.
Manual mode is used when you wish to control the load outside the hours set in the events
schedule.
In manual mode, the thermostat output is still associated to the sensor temperature via the
thermostat heating temperature ([TEMP] parameter). In this mode, the controller allows
the output to be turned on during the period programmed in the parameter [,F05].
5.3.1 VACATION MODE
To enable/disable the Vacation mode, the key must be held for 4 seconds.
AUX
off
4 seconds
When enabled:
The event schedule is ignored, the support outlet is turned off, resulting in energy
consumption reduction.
Obs.: In thermostat mode settings, the controller takes on the new mode 5 seconds after
its selection. This also is the time necessary for the parameter to be stored in its memory.
A
button you can change the operating mode of the
AUT = Thermostat in automatic mode, operating
according to the configuration of the events
schedule and sensor temperature.
MAN = Thermostat in manual mode. It remains in
this mode for the time set in [,F05]- thermostat
MAN
manual override time, and returns to AUT mode
after this time has elapsed.
A
OFF: vacation mode enabled.
and
keys to

Advertisement

loading

Summary of Contents for Full Gauge Controls Microsol RST Advanced

  • Page 1 Ver. 02 1. DESCRIPTION 4.2 INDICATIONS The Microsol RST Advanced is a digital thermostat with control logic for In programming, cleared parameter setting heating or cooling. The unit is equipped with a clock, events schedule for rational and In programming, blocked parameter setting economical use of the controlled load, and protected access to configuration parameters.
  • Page 2 Programmed case [,F06] = [,2T6] 5.4 TIME AND DAY SETTINGS In order to access the Time and Day menu, just give a short touch on the key. Through the or keys it is possible to navigate among the parameters. In order to edit them press 2 seconds the SET key and through the Sunday...
  • Page 3 6.2 TABLE OF PARAMETERS CELSIUS FAHRENHEIT Description Unit Standard Unit Standard [CoDE] Access code [,F01] Thermostat control logic Heat Heat Cool Heat Cool Heat [,F02] ºC ºF Thermostat temperature hysteresis 20.0 [,F03] Minimum allowable setting for the thermostat temperature (TEMP parameter) ºC ºF [,F04]...
  • Page 4 If in doubt, please contact Full Gauge Controls. Push the rear openings Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) necessary for the passage yearwarranty, as of the date of the consigned sale, as stated on the invoice. They are of cables;...