Creating a new array and logical drive

Open CPQONLIN and select the controller that you want to configure.
1.
The Logical Configuration View panel appears.
Press the Enter key.
2.
The highlight moves to the Controller Options panel.
Highlight the Create New Array option, and then press the Enter key.
3.
The screen displays three panels (Create Array, Physical Drives, and New Array), and the highlight
moves to the Create Array panel.
Highlight the Assign Drive option, and then press the Enter key.
4.
The highlight moves to the Physical Drives panel.
Highlight a drive that you want to be part of the array, and then press the Enter key.
5.
The New Array panel displays the added drive, and the highlight returns to the Create Array panel.
Repeat steps 4 and 5 until you have finished building the array.
6.
For the most efficient use of drive space, select physical drives of comparable capacity.
o
For optimum system performance, select physical drives that are connected to different ports on the
o
controller.
If you intend to create a RAID 5 configuration, keep the risk of logical drive failure low by assigning
o
no more than 14 physical drives to the array.
Do not select any physical drives that you want to be spare drives. Spare drives are created in a
o
separate procedure
Highlight the Accept Changes menu option, and then press the Enter key.
7.
The Create New Logical Drive panel appears.
Select the RAID level that you want the logical drive to use, and then press the Enter key.
8.
Select the stripe size that you want the logical drive to use, and then press the Enter key.
9.
Enter the capacity that you want the logical drive to have, and then press the Enter key.
10.
Press the Esc key to save the settings and return to the Logical Configuration View panel.
11.
To make new logical drives available for data storage, format them using the instructions given in the
12.
operating system documentation.

Adding spare drives

Assigning one or more online spare drives to an array enables you to postpone replacement of faulty drives.
However, it does not increase the fault-tolerance level of any logical drives in the array. For example, a
logical drive in a RAID 5 configuration suffers irretrievable data loss if two of its physical drives are
simultaneously in a failed state, regardless of the number of spare drives assigned to the array.
Any drive that you want to use as a spare must meet the following criteria:
It must be an unassigned drive or a spare for another array.
It must be of the same type as existing drives in the array (for example, SATA or SAS).
It must have a capacity no less than that of the smallest drive in the array.
To add a spare drive to an array:
("Adding spare
drives" on page 18).
HP Online Array Configuration Utility for NetWare 18