Adam BTT User Manual

Touch-screen label printing scale (ae 505 indicator)

Advertisement

Quick Links

BTT
Touch-screen Label Printing
Scale
(AE 505 Indicator)
USER MANUAL
Revision 3, 04/25 / Software version 2.1.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BTT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Adam BTT

  • Page 1 Touch-screen Label Printing Scale (AE 505 Indicator) USER MANUAL Revision 3, 04/25 / Software version 2.1.2...
  • Page 2: Table Of Contents

    Counting function (Option Hi Lo) ............. 32 Select and edit goods ................. 34 Print ......................39 Check the record.................. 39 Parameter setting ................48 Communication ..................59 Time setting ..................81 Dealer setting ..................82 update ....................83 © Adam Equipment Company 2025...
  • Page 3 Please read carefully following instructions for installation and use before starting your work with a new balance. Failure to use the balance in accordance with the advice in the user manual could mean that the product gives incorrect readings. © Adam Equipment Company 2025...
  • Page 4: Introduction

    If not in use, charge machine every three months to prolong battery life. Ensure the battery has a full charge before next use. Your Adam Equipment scale is a precision instrument. Please use and handle with care, and place items on its weighing pan carefully.
  • Page 5: Specification

    Power adapter: 12VDC 3A adapter. Working current: 300mA Display: 8-inch TFT Sensor sensitivity range: 1-3mV/V Power: DC6V/4-10.0AH (low power sign appears when voltage lower than 5.6V) Work temperature: 0-40℃, lower than 90% RH. Storage temperature: -25~55℃ © Adam Equipment Company 2025...
  • Page 6: Assembly

    Connect to the shielded wire (Option) To assemble your BTT, feed the load cell cable through the pillar, then insert the pillar into the base, and fasten the fixed screw. Position the cable through the holder and insert the holder into the bracket of the indicator.
  • Page 7 USB1 can connect to a USB flash drive and barcode scanner. USB2 is an optional extra. RS-232 1# can connect to PC. RS-232 2# can connect to an external printer. © Adam Equipment Company 2025...
  • Page 8: Getting Started

    With the scale switched on, press the On/Off button. The screen will display the shutdown dialogue: Choose to turn off, Choose to close the screen but not power off. Press On/Off again; the screen will show again. Choose to return to working mode. © Adam Equipment Company 2025...
  • Page 9: Charging

    Only use the adapter supplied with the product, or an official Adam Equipment replacement adapter. Display Weighing window In Weighing mode, the screen shows net weight, tare weight and gross weight. In Counting mode, the screen shows net weight, unit weight and quantity. © Adam Equipment Company 2025...
  • Page 10 8.1.4 Stable - means the weight value has stabilised and a reading can be taken. Status bar User login 8.2.1 Capacity and Division 8.2.2 Barcode scanner 8.2.3 External printer connection 8.2.4 USB flash drive 8.2.5 WIFI 8.2.6 Battery charge status 8.2.7 Date and time 8.2.8 © Adam Equipment Company 2025...
  • Page 11: Screen Keypad

    Screen keypad 9.1 English mode Symbol and number mode The second page of symbol and number mode Close the keypad. © Adam Equipment Company 2025...
  • Page 12 Backspace Enter Shift, Caps Lock Space, English or Chinese input. Symbol/number keypad switch Switch to English or Chinese input mode Symbol mode switch Toggle between English or Chinese keypad. © Adam Equipment Company 2025...
  • Page 13: Function Buttons

    If pressing this key does not return the scale to zero, please check if the weight value exceeds the allowed zero range. Users can set the manual zero range in Menu > User Settings > Functions. Input tare weight. After pressing this key, the 10.6 © Adam Equipment Company 2025...
  • Page 14: Other Interfaces

    (OK) and higher than the high limit. The third row displays the same as the second row but showing as the weight value. Check Counting mode 11.1.2 © Adam Equipment Company 2025...
  • Page 15 When the weight or quantity value is more than the Lo value, but less than Hi VALUE, the OK box glows green. When the weight or quantity value is more than the Hi value, the Hi box is red. © Adam Equipment Company 2025...
  • Page 16 When selecting the product, the Hi-Lo value will set to this goods’ Hi-Lo information. 11.1.4.2 Modifying the Hi-Lo value manually To change Hi-Lo setting, press the Hi-Lo box. The Hi- Lo setting box will pop up. © Adam Equipment Company 2025...
  • Page 17 Press Confirm again to go back to weighing mode. The Hi-Lo values have now changed to the inputted values. 11.2 Percentage weighing (Target (%)) mode Percentage weighing mode is similar to Checkweighing (Hi/Lo limit) mode. The example in weighing mode is as follows: © Adam Equipment Company 2025...
  • Page 18 Sorting mode is used for goods classification. From top to bottom, the information is sorting value, sorting range, the sorting count, the total sorting weight. For example, when the weight value is between 1.0kg and 2.0kg, © Adam Equipment Company 2025...
  • Page 19 . 11.3.2.2 Modifying the sorting value manually If you do not wish to select a product/goods, or you need to change sorting setting, press the sorting box, and the sorting setting box will pop up. © Adam Equipment Company 2025...
  • Page 20: Subtotal

    You can activate the Subtotal function in Dealer Settings > Functions. The subtotal value and the option to clear the subtotal value will show in the left bottom of the display. © Adam Equipment Company 2025...
  • Page 21: Add Up

    Functions , the lower left of the screen will show the relevant keys. 13.2 Keys Press this key to add up current weight or quantity. Press this key to recall every all weights, quantities and totalised weights and quantities. © Adam Equipment Company 2025...
  • Page 22 Pressing will print all values, and delete the data immediately after printing. Press to print totalised value, and delete the data immediately after printing. This key can delete all add up value. After © Adam Equipment Company 2025...
  • Page 23: Stock Function

    Add the item to the scale and press The weight or quantity will add to the stock value of the current item. At the same time, the stock value will show the latest stock value of the current item on the left. © Adam Equipment Company 2025...
  • Page 24 Check stock 14.3 When opening the stock management function, the stock value of every item will show in the choose goods interface. If the user has selected counting mode, the stock quantity will show in here © Adam Equipment Company 2025...
  • Page 25: Show Barcode

    The display format will change upon a change in weight. means the QR code will Selecting show on the lower left of the screen, and the barcode will display under the goods. This function can show barcode and QR code at the same time. © Adam Equipment Company 2025...
  • Page 26 When the code shows on the left, the Hi-Lo status will not show. At this time, the code in the left will change colour following the Hi-Lo status. For example, yellow means weight is below the Lo setting. © Adam Equipment Company 2025...
  • Page 27: Using A Barcode Scanner

    In this example, customer, order number and batch number are all the user defined name. The input box is a free text box. Users can also select the drop-down to choose the type of value. © Adam Equipment Company 2025...
  • Page 28: Power On Zero

    If the user wants to show the last weight value when power is on, please set the power on zero range to 0. © Adam Equipment Company 2025...
  • Page 29: Zero

    If the scale is broken or weight is heavy than allowed zero range, this key is invalid. If the display has rest weight value when the pan is empty, please use this function. Zero range= Max. Cap. X4%. Zero range can be set in user settings. © Adam Equipment Company 2025...
  • Page 30: Tare

    20 Tare Tare weight is known. 20.1 key, Tare weight input window will pop-up, Press please input the tare weight. Then press [confirm], the scale will reduce that tare weight value automatically. © Adam Equipment Company 2025...
  • Page 31 © Adam Equipment Company 2025...
  • Page 32: Choose Units

    21 Choose units If the units are not the suitable one, press key to choose the right units.The units which can be used are set in the user settings. © Adam Equipment Company 2025...
  • Page 33: Counting Function (Option Hi Lo)

    Set the unit weight in item edit step, Choose the unit weight by select goods. To manually set the U.W press the U.W in the top right 22.3 corner and the function window will pop-up. © Adam Equipment Company 2025...
  • Page 34 Unit weight is known 22.3.1 Input the known weight of weights, press ,the display will show the U.W in the top right corner display. © Adam Equipment Company 2025...
  • Page 35: Select And Edit Goods

    , then press key in top right corner, this will take you back to weighing interface, the item will show in the item bar. © Adam Equipment Company 2025...
  • Page 36 New goods can also be added in the goods selection and editing screen press New Different data can be added to new or edited goods depending or which function is selected The add new item window will pop up after press. © Adam Equipment Company 2025...
  • Page 37 If item does not have a Tare weight it can be left blank or set to Hi limit is the maximum allowed limit of goods when Hi-Lo function is opened. In counting mode, the unit is PCS © Adam Equipment Company 2025...
  • Page 38 After input all, press goods in goods interface. edit 23.1.5 Highlight the goods to be edited, press Item edit interface as follows: Number cannot be edited, other functions are the same as add new item. © Adam Equipment Company 2025...
  • Page 39 Select the goods which need to be Deleted, and press delete. Export 23.1.7 Insert the USB flash drive in the back of the indicator and press export. Select USB disk. Press OK. USB stick can now be safely removed Search [all search bars] 23.1.8 © Adam Equipment Company 2025...
  • Page 40: Print

    Note: print function is limited to print settings which are in communication settings. If the condition is suitable, the scale will inform store success. 25 Check the record Press to open print records and stats: see follow picture: © Adam Equipment Company 2025...
  • Page 41 Statistics mode, shows the printed records are counted according to certain rules, not the original printed records. 25.1 Standard report In standard report mode, users can choose date range, press will pop up the date selection window. © Adam Equipment Company 2025...
  • Page 42 Daily reports are different with standard reports, it just shows one day’s data, the interface as follows: In daily report interface, data bar just shows one day’s data which to go back to has been chosen. Press © Adam Equipment Company 2025...
  • Page 43 Monthly reports are different to standard reports, it just shows one month’s data, the interface as follows: User choose month, press can back to current month quickly. to refresh the After set the month, the user also need press data. © Adam Equipment Company 2025...
  • Page 44 Statistics interface dose not have a delete function, Statistics can be viewed by item, type in the item number in the to refresh. search bar and press The data list will add up the same item’s data to together, such as © Adam Equipment Company 2025...
  • Page 45 At the same time, show the total data of all items. Statistics by Hi-Lo 25.4.1 The date list will add up the same item’s data and their Hi-Lo results together. Statistical can be refined by user set groups . 25.4.2 © Adam Equipment Company 2025...
  • Page 46 Press to refresh the data. After chose the date, user need to press Monthly statistics 25.6 Works the same as standard statistics, but only allows one months worth of data as follow: © Adam Equipment Company 2025...
  • Page 47 25.7 Re print In report mode, use can choose the date which needs to reprinted, Highlight the data row and then press 25.8 Export Insert the USB flash drive, Report and statistics mode all can export data. © Adam Equipment Company 2025...
  • Page 48 USB flash drive. delete 25.9 Highlight the item line, press , This deleted data cannot be recovered. In statistics mode, data cannot be deleted. 25.10 Delete all Press about 3 seconds, the delete all data © Adam Equipment Company 2025...
  • Page 49: Parameter Setting

    25.11 searching In every report interface, include statistics interface, users can input the key words into the search box to search for the item which includes the key Then press words input. 26 Parameter setting © Adam Equipment Company 2025...
  • Page 50 In weighing interface press will pop up setting menu. Press to enter the parameter settings. The window is as follows: © Adam Equipment Company 2025...
  • Page 51 Press interface will show out, as follow: Tick the unit which you require when the unit key is pressed on the home scree example Only the units which are ticked can be chosen through the © Adam Equipment Company 2025...
  • Page 52 Standard Unit setting is g, user can it change where required. Function setting 26.2 for function setting interface Press © Adam Equipment Company 2025...
  • Page 53 12s. If the indicator is operated or the weight value changes, the back light will turn back on. If it is set to OFF, the back light will keep the set brightness and never become dark. The setting details are as follows: © Adam Equipment Company 2025...
  • Page 54 The default difference is 20%. More details please refer to point 18. Manual zero range 26.2.4 Allows the user to zero the balance when the weight is with in set % Difference The default difference is 4%. © Adam Equipment Company 2025...
  • Page 55 Automatic add up 26.2.7 Once weighing is stable, scale will add up current weight and quantity. Note: scale needs to be clear and back to zero Before the next weight is added 26.3 Hi-Lo function © Adam Equipment Company 2025...
  • Page 56 Hi Lo parameters 26.3.1.2 Negative Alarm Alarm will sound when value is negative. 26.3.1.3 Zero Alaram Alram will sound when weighing value is zero. 26.3.1.4 Alarm needs stability The alarm will not work unless stable © Adam Equipment Company 2025...
  • Page 57 26.4 Variable edit Allows the user to add additional scanners. (point 17 user defined input function), press will show variable edit interface as follows: To add content into the variable box, press © Adam Equipment Company 2025...
  • Page 58 After pressing add the input box will be updated on the input box on main screen: press © Adam Equipment Company 2025...
  • Page 59 USB automatically. After backup succeed, the message “back succeed” will pop up. Restore 26.5.2 Insert the USB which has restore files, press restore. The latest backup data of scale will be retored, include settings and stored data. © Adam Equipment Company 2025...
  • Page 60: Communication

    27 Communication 27.1 setting Press , then press in the pop-up window: 27.2 Serial port 1, Serial port 2, Serial port 3 The settings for 3 serial ports are the same. © Adam Equipment Company 2025...
  • Page 61 Interface as follows: Mode 27.2.1 Includes: close, continuous, stable, Response, Manually & print mode. © Adam Equipment Company 2025...
  • Page 62 27.2.1.2 Baud rate Users can choose baud rate here, highest is 11520, and the default is 9600. This baud rate needs to match the same as PC or printer’s baud rate. © Adam Equipment Company 2025...
  • Page 63 Protocol 27.2.2 Communication format is set to print mode. 0-4 are built-in printer’s print format. 5-10 are user defined print format. Use PC downloaded print format to the scale, 27.2.3 Paper cut © Adam Equipment Company 2025...
  • Page 64 Factory fitted and requires to be requested on order and is 27.3 subject to lead time Here’s Bluetooth is the Bluetooth of host mode, usually connect with Bluetooth printer. Press the Bluetooth setting interface will show. A s follows: © Adam Equipment Company 2025...
  • Page 65 The details are the same as serial port setting. 27.3.2 Cut paper It means when users use the printer which has cut paper function, can set if need cut paper here. The details are the same as serial port setting. © Adam Equipment Company 2025...
  • Page 66 Users can search for Bluetooth 2.0 and Bluetooth 4.0(BLE) equipment. Bluetooth name followed with [SPP] is Bluetooth 2.0equipment. Bluetooth name followed with [BLE] is Bluetooth 4.0equipment. Bluetooth name followed with [paired] is Bluetooth 2.0equipment and paired already. © Adam Equipment Company 2025...
  • Page 67 Now input the PIN, PIN is 0000 or 1234 usually. Press OK it will show connected and run connection. If the equipment is already paired or the equipment is Bluetooth 4.0[BLE], there is no need to run pairing, press connect, and the connection will run directly. © Adam Equipment Company 2025...
  • Page 68 Factory fitted option and requires to be 27.4 requested on order and is subject to lead time If the scale has Wi-Fi module or Ethernet module, Press Network button Wi-Fi module’s interface is as follows: 27.4.1 © Adam Equipment Company 2025...
  • Page 69 It will show the related hot-spot name and signal strength. Input the password, press If connect is succeed, here will show: Once connected restart the scale and the Wi-Fi symbol should be showing on the screen © Adam Equipment Company 2025...
  • Page 70 For example, if the sub-net mask is 255.255.255.0 and the default gateway is 192.168.0.1, the IP address can be 192.168.0.2-192.168.0.255. In addition, the IP address cannot conflict with other devices on the network. Ethernet interface as follows: 27.4.2 © Adam Equipment Company 2025...
  • Page 71 Close mode: network server is off. Keep server mode closed when not being used or connected. Keeping the server closed can reduce CPU usage and improve the reaction speed of electronic balance. © Adam Equipment Company 2025...
  • Page 72 IP address and server port. Network client 27.6 Network clients actively connect to other servers, such as a computer created network server, Pressing will show network client interface as follows: © Adam Equipment Company 2025...
  • Page 73 It’s the IP address of the network server to connect to, such as the local IP address of the computer Port 27.6.4 It’s the port of the network server to connect to, such as the server port set when the computer. Heartbeat Packet Interval 27.6.5 © Adam Equipment Company 2025...
  • Page 74 For example, if the value is set to 3, heartbeat packets are sent for three consecutive times, but the scale still does not receive heartbeat packet data from the server. In this case, the electronic scale considers that the network connection has been disconnected. © Adam Equipment Company 2025...
  • Page 75 Print setting 27.7 Press will show print setting interface as follows: Print mode 27.7.1 © Adam Equipment Company 2025...
  • Page 76 Qualified print 27.7.2 In Hi-Lo function, once the weight value or quantity is in qualified range, printing will be allowed. Manual print and automatically printer all been control by this setting. © Adam Equipment Company 2025...
  • Page 77 Other settings, such as Comm1, which is set to print mode need weight value or quantity in qualified range, then can print. Other serial ports do not have affect, include store data. Print control 27.7.3 © Adam Equipment Company 2025...
  • Page 78 The new printed net weight is the weight of the newly added material, and the gross weight is the weight of all materials in the container. © Adam Equipment Company 2025...
  • Page 79 In this interface, user can delete or import format. ⚫ The format column corresponds to the protocol of the serial port or printer Settings. ⚫ The first single column can delete the format existing in the © Adam Equipment Company 2025...
  • Page 80 The second M+ column can import format from a USB. files can be generated by using the export function of the print format editor Cut paper 27.7.7 It is the cut paper function of USB printer. © Adam Equipment Company 2025...
  • Page 81 Users can read and write data through the serial port and also can download and read the item data and weighing record. Scale address 27.7.9 © Adam Equipment Company 2025...
  • Page 82: Time Setting

    27.7.11 barcode Used to set whether barcode can show or not on the main interface. For details, please check point 15. 28 Time setting Press in the pop-up , then press window: © Adam Equipment Company 2025...
  • Page 83: Dealer Setting

    Note: The time section is in 24-hour format. For example, 1pm should be set to 13:00. 29 Dealer setting Press , then press Input the password then can enter into the Dealer setting. 123456 Dealer settings can only be modified by the dealer © Adam Equipment Company 2025...
  • Page 84: Update

    31 close If user wants to close the menu, can press 32 User management (option) When user management been opened in Dealer setting, user can press user manager in menu. © Adam Equipment Company 2025...
  • Page 85 User has the permission to set user parameters, communication settings, and time settings. ⚫ allows editing items User has the permission to add, edit and delete items, but even without the permission to edit items, the user can still © Adam Equipment Company 2025...
  • Page 86 Default Login 32.1.4 Select the user to log in by default. Click Default login to display the user in the text box on the right. © Adam Equipment Company 2025...
  • Page 87 , then press Note: This button cannot be clicked if the user management function is not enabled in Dealer Settings. Enter the old password and the new password, then click OK to complete the change. 32.3 Exit © Adam Equipment Company 2025...
  • Page 88 User can press to select the existing user, enter the correct password, and then press to login. After successful login, the logged in user will be displayed in the upper left corner of the weighing interface © Adam Equipment Company 2025...
  • Page 89: Use Pc For Data Management

    The delete button here only deletes the data in the list of the software, not the data in the scale. ⚫ export User can export the data of list to excel file. ⚫ Due to the different content of each intelligent scale, the format of © Adam Equipment Company 2025...
  • Page 90: Communication

    Indicator with female connector (factory default) Connect to Indicator (male Connect to PC port (female connector) connector) Define Define Indicator with male connector Connect to Indicator (female Connect to PC port (female connector) connector) Define Define © Adam Equipment Company 2025...
  • Page 91 Read tare weight 52 54 Read gross weight (GROSS) 52 47 Read inner code 52 43 Read unit weight (counting 52 55 mode is opened) Read quantity (counting mode 52 51 is opened) zero 53 5A © Adam Equipment Company 2025...
  • Page 92: Units Conversion

    +9e more that the Max. Cap. Batter sign Low power Charging Low battery, Battery ‘voltage is Stop using and charging please very low charging 37 Common Usage Scenarios Test whether the goods are qualified 37.1 © Adam Equipment Company 2025...
  • Page 93 ⚫ More details please check point 11.3. 37.3 ERP system needs to input weight through the barcode scanner Set the barcode or QR code to be shown in the main interface ⚫ in communication setting. © Adam Equipment Company 2025...
  • Page 94 The label editor needs to be set up for cumulative printing Download format to scale, the serial number is generally the ⚫ same as a single print serial number. ⚫ print total weight quantity, press can print the total quantity and weight. © Adam Equipment Company 2025...
  • Page 95 Users can also enter the employee number or name to search records, so that only the weighing record of a certain employee’s can be seen. ⚫ In the statistics page, users can choose to collect statistics by © Adam Equipment Company 2025...
  • Page 96 ⚫ Download the format to scale, pay attention to download serial number do not conflict with other used serial numbers, and the corresponding port protocol should be set to the corresponding value. © Adam Equipment Company 2025...
  • Page 97 During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company. The company or its authorized Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems.
  • Page 98 Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. © Adam Equipment Company 2025...
  • Page 99 State of California to cause cancer and birth defects or other reproductive harm ADAM EQUIPMENT is an ISO 9001:2015 certified global company with more than 40 years’ experience in the production and sale of electronic weighing equipment.
  • Page 100 © Copyright by Adam Equipment Co. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment. Adam Equipment reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.

Table of Contents