Page 1
Text in italics is specific for emergency variants. Overview Safety Instructions Installation Maintenance Technical Specification Important information The URBAN series of industrial luminaires are specialist devices, for use in specific operating environments. The units must be installed in accordance with these instructions and must be installed by suitably qualified personnel. If you have any queries about the installation or the certification of the unit – please contact Raytec for immediate assistance and advice.
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. Replace any cracked protective shield Order SPX-BKT-RL-G2 from Raytec Ltd 1.5m Install in a well Eye Safety - Risk Group...
2. Installation Mounting URBAN Unit It is recommended that a MINIMUM of 2 fixing points must be used, the fixing points must be suitable for the conditions of use. The URBAN product is supplied with eye bolts to allow the product to be suspended. Dimensional Diagrams WL84 548mm (21.6”) WL168 1015mm (39.9”) UK / Europe Tel: +44 (0) 1670 520055 www.raytecled.com Americas Tel: +1 613 270 9990...
Page 5
Wiring Diagram – Standard Version LED PCB WHITE ORANGE DALI DALI BLUE GREEN MAINS IN LED + LED - 150-264Vac BROWN DALI DALI EARTH NEUTRAL LIVE Wiring Diagram – Emergency Version END COVER (WITH BATTERY) BLACK CONNECTOR BATT + BATT - LED PCB EMERGENCY IN +...
Page 6
The standard product is supplied with 2m of flex for terminating into a suitable plug, connector or terminal box. The mains supply flex on a standard unit is 3 core and is identified as the Green/Yellow (Earth), Brown (Live) and Blue (Neutral) terminals. Emergency units are supplied with a 4 core flex and identified as Green / Yellow (Earth), Grey (Neutral), Brown (Permanent Live), Black (Switched Live). DALI dimming is available as standard. 2 core flex is provided for DALI connection, cores are identified as Red and Black. Cores are polarity free.
Page 7
URBAN Intelligent Emergency Operation Guide The Emergency version is equipped with a self-test functionality according IEC62034. • 28 days after power-up the driver will perform a functional test of 30 seconds. • Every 6th test (after half a year) will be a duration test. This test will run until the battery is fully discharged and the driver will verify if the capacity of the battery is sufficient to provide 3hrs emergency time.
Page 8
LED Status Indicator LED indicator Error condition Cause Solution (colour / flashing) Green / no flashing System OK, battery fully charged Mains off, EM mode, Rest mode, test in progress Green / slow System OK, battery is charging 0.25s on, 1.25s off Green / fast System OK, recently tested (<...
4. Technical Specification Input Voltage 150-264V AC Input Current 0.13A (230Vac, full load) 36W WL84 STD / 72W WL168 STD Consumption 39W WL84 EM / 75W WL168 EM Power Factor >0.92 (230Vac, full load) Mains Frequency 50/60Hz Inrush Current (I @50%) 20A, ∆t < 300µs peak...
Page 10
Inrush Current Typical Curve Max number of fittings allowed per MCB (Based on 230V) MCB Type Rating www.raytecled.com UK / Europe Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
Page 11
UK / Europe Tel: +44 (0) 1670 520055 www.raytecled.com Americas Tel: +1 613 270 9990...
Page 12
For the most current and detailed information about our products, please contact our sales team at sales@raytecled.com.dom Raytec Global (excluding Americas) Raytec Americas Tel: +44 (0) 1670 520055 Tel: +1 613 270 9990 sales@raytecled.com...