  • Page 1 Combined Installation Guide VARIO2 w16 VARIO2 i16 VARIO2 w8 VARIO2 i8 VARIO2 i6 VARIO2 w4 VARIO2 i4 VARIO2 w2 VARIO2 i2 Quick Installation Guide Page 3 Full Installation Guide Page 12...
  • Page 3 Quick Start Guide Eye Safety White-Light, 730nm and IR Variants (850nm & 940nm) Information: Caution – Risk Group 2. Avoid Exposure / use protection. See Safety Information in FULL Instruction Guide for details. Box Contents: VARIO2 Illuminator with 35° ILS fitted, spare 60° beam angle ILS, User Guide (ILS: Interchangeable Lens System) Optional Accessories: Remote Controller for additional programming, 80˚...
  • Page 4 IP66 correctly located and the screws correctly fastened to ensure and rating of the product. maintain IP66 rating of the product rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 5 Disable / Enable Enable - Green to programming Programming Mode Push Mode. Disable remote and Operating Mode (enter OP Mode) or Enable remote (enter Programme Mode) rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 6 If no buttons are pressed within 2 minutes then the illuminator will automatically default back into the previous mode it was in – programming or operating mode. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 7 Power 5, Power 1, Min Photocell (Smallest Moon), Max Timer (Full Red Circle) & Timer Disable (Timer Circle image with a line through). Note - invalid characters will not be recognised. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 8 Flashing Red (Standard LED of Characters seconds times / Green indication) required For full PIN function detail (inc valid PIN characters) – see FULL instruction guide. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 9 (if done at the same time as disabling the remote – see FULL Instruction Manual Status Indicators Enable/Disable, entering a PIN or disabling manual buttons (if done at the same time as disabling the remote – see FULL Instruction Manual. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 10 • If longer cables used, ensure sufficient voltage is provided to allow for drops across the cable For in-depth Troubleshoot, see Full Instructions, or contact Raytec. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 12 Full Installation Guide VARIO2 w16 VARIO2 i16 VARIO2 w8 VARIO2 i8 VARIO2 i6 VARIO2 w4 VARIO2 i4 VARIO2 w2 VARIO2 i2 Contents Page 13 Box Contents and Safety Information Page 15 Installation Steps and Factory Defaults Page 16 Complete Set Up and Installation Page 18 LED Status Indicators –...
  • Page 13 For VAR2-w2-1, VAR2-w4-1, VAR2-w8-1 and VAR2-w2-2, VAR2-w4-2 variants hazard distance is 1500mm. For VAR2-w16-1 and VAR2-w4-3, VAR2-w8-2/-3 variants hazard distance is 1840mm. Eye Safety: Other Wavelengths - Contact Raytec. The Illuminator is Class lll for insulation Illuminators are suitable for use Outdoors and Indoors rayteccctv.com...
  • Page 14 Pour VAR2-w16-1 and VAR2-w4-3, VAR2-w8-2/-3 maintenir une distance de sécurité de 1840 mm. Sécurité des yeux : Autres longueurs d’onde - Contactez Raytec. Le projecteur est de la classe d’isolation III. Les projecteurs conviennent pour une utilisation extérieur et intérieur...
  • Page 15 The external cable cannot be replaced. If it is damaged and the customer is unable to shorten and re-use the cable, the illuminator must not be powered. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 16 IMPORTANT NOTE: Ensure base plate is securely located, the gasket is correctly located and the screws correctly fastened to ensure and maintain IP66 rating of the product. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 17 TTL input. Volt free input/dry contact: Non polarity sensitive, short circuit = light on TTL input: Orange = TTL +ve, Purple = TTL –ve (GND) 0V = Light on, 3V = Light off rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 18 The LED Indicators also give feedback if you are using the Remote (see separate instructions provided with the remote) or PIN Function and Manual Control Modes (See Pages 22 to 29). Left Hand Right Hand Side LED Side LED rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 19 If a PIN is present the unit will return to Operating mode after a power interruption. Factory Default: On initial power-up, Programming Mode, No PIN present. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 20 Note: Reset button will not remove a PIN if one is present Note: Unless detailed as part of the functionality, if an invalid or blocked command is attempted, both LEDs will flash RED rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 21 PIN Mode Note: Unless detailed as part of the functionality, if an invalid or blocked command is attempted, both LEDs will flash RED rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 22 If legal characters but not the correct sequence of characters is entered the number of flashes will still reduce and after 4 characters have been entered an error will be shown by both LED`s flashing RED. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 23 The illuminator will return to programming mode. Note – if you delete the PIN and the illuminator times out into operating mode, you will not be able to go back to programming mode without recycling the power. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 24 Disable Remote Control and enter Operating Mode or Enable Remote Control Remote Control and enter Programming Mode and enter Programming Mode 6. Button Enable & Disable Button Enable & Disable 12 rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 25 Manual Button Enable / Disable NOTE: If the status indicator LEDs are disabled and you use the manual buttons the indicator LEDs will still illuminate accordingly. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 26 RHS LED will be stored into the illuminator memory. The settings programmed will be retained on power recycling unless a reset has been performed, in which case the factory defaults will be applied. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 27 NOTE: If no buttons are pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in – either operating or programming mode. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 28 NOTE: If no buttons are pressed within 2 minutes the illuminator times out and returns to the previous mode it was in – either Programming Mode or Operating Mode. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 29 NOTE: This command can only be used within 5 minutes of the illuminator being put into Operating Mode using the Remote Control. (If the Manual Buttons are already disabled, both LEDs will flash RED straight away) rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 30 This is a FULL RESET and will restore factory settings AND remove the PIN if one has been set. Both Indicator LEDs will flash AMBER when completed. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 31 53mm Optional Bracketry (not to scale - other Bracketry also available) VUB-PSU Plate VUB-Pole VUB-Wall VUB-Plate (Various Sizes) Pole Mount Wall Mount Ptz Mount Dome Mount Raytec Global Tel: +44 (0) 1670 520055 rayteccctv.com Americas Tel: +1 613 270 9990...
  • Page 32 2.5m 2.5m 2.5m 2.5m For 730nm, IR 940nm and other wavelengths, contact Raytec for distances • For i16; w16; i8; w8 the supply to the units should be limited to/ fused at 5A • For i6; w4 the supply to the units should be limited to/ fused at 3.15A •...
  • Page 33 (zero volt or TTL) is applied and correctly wired Step 3: Set up camera, lens, and illumination • Check model number to Raytec performance specification to ensure required distance is achievable; • Check unit is set to max power •...
  • Page 34 Battery failure. Check battery on remote (CR2025). Test 3 volt battery, replace if necessary. Ensure battery has clean contacts. • Remote failure. Test with new remote. rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 35 Illuminator shall be disposed of and re-cycled where possible.) Raytec Warranty All Raytec luminaires are provided with an industry leading 5 year warranty and have an expected useful life in excess of 10 years. Contact Raytec for more details.
  • Page 36 Raytec Global (excluding Americas) Raytec Americas Tel: +44 (0) 1670 520055 Tel: +1 613 270 9990 sales@rayteccctv.com ussales@rayteccctv.com Raytec Ltd. Raytec Systems Inc. Unit 15 Wansbeck Business Park, Rotary Parkway 800-300 Terry Fox Drive, Ottawa, Ontario Ashington, Northumberland, NE63 8QW, United Kingdom 2K 0E3, Canada rayteccctv.com...