Technical Specification Trouble Shooting Important information The WARRIOR HP series of industrial floodlights/highbay are for use only in industrial environments. The units must be installed by suitably qualified personnel. If you have any queries about the installation or the certification of the unit –...
The end user must ensure that these materials are suitable for the environment the WARRIOR unit will be installed in; Zone 1 and Zone 2 Hazardous areas.
2. The line diagrams below are for guidance only - units may be mounted in any orientation. Mounting HP WARRIOR Unit – Floodlight Application www.raytecled.com UK / Europe Tel: +44 (0) 1670 520055...
Page 5
Mounting WARRIOR Unit – Highbay Application 422 (16.6") 353 (13.9") 33 (1.3") UK / Europe Tel: +44 (0) 1670 520055 www.raytecled.com Americas Tel: +1 613 270 9990...
Connect wires to mains supply. If the unit is opened for any reason, disconnect mains. All WARRIOR floodlights/highbay have terminal blocks suitable for looping 4mm2 cable, only one cable should be connected to each terminal block connection.
Isolate the WARRIOR unit from the mains supply and allow to cool before carrying out any maintenance work. The unit has 2 independent power supplies; in the event that a power supply needs to be replaced remove the cover to get access to the power supply.
4. Technical Specification 120W version 300W version 150-264V AC/DC or 110-264V AC/DC Input Voltage see certification nameplate on product Input Current (230Vac, full load) 0.52A 1.4A Consumption 120W 300W Power Factor (230Vac, full load) >0.97 Mains Frequency 50/60Hz Inrush Current (I @50%) 53A, ∆t <...
Page 9
Inrush Current Typical Curve Twidth Max number of fittings allowed per MCB SPZ/SPX-HP10K SPZ/SPX-HP15K SPZ/SPX-HP20K SPZ/SPX-HP25K MCB Type Rating (120W Version) (180W Version) (240W Version) (300W Version) UK / Europe Tel: +44 (0) 1670 520055 www.raytecled.com Americas Tel: +1 613 270 9990...
Page 10
4.1 DALI Wiring Instructions Table below shows the maximum cable length L between two units. Cable lengths of more than 300m are not recommended. The maximum allowed voltage drop on DALI bus system is 2,0V. Maximum cable length L in m Cross section in mm 25°C 50°C...
5. Troubleshooting Ensure the two LED boards are correctly wired to terminal block. Red to Red : Black to Black – paired cables Ensure Mains input is correctly connected. Ensure Mains Input is turned on at the source. If LED panel fails to light is it possible to identify if problem is with LED panel or power supply by swapping LED cables to opposite power supply to help identify problem.
Page 12
Raytec Global (excluding Americas) Raytec Americas Tel: +44 (0) 1670 520055 Tel: +1 613 270 9990 sales@raytecled.com sales@raytecled.com Raytec Ltd. Raytec Systems Inc. Unit 15 Wansbeck Business Park, Rotary Parkway 800-300 Terry Fox Drive, Ottawa, Ontario Ashington, Northumberland, NE63 8QW, United Kingdom 2K 0E3, Canada raytecled.com...