Download Print this page
Raytec SPARTAN SPX Installation Manual

Raytec SPARTAN SPX Installation Manual

High power luminaire range
Hide thumbs Also See for SPARTAN SPX:

Advertisement

Quick Links

SPX/SPZ
High Power Luminaire Range -
Installation Guide
Zone 1 and 21 Variant CML 17ATEX1148 & IEC Ex CML17.0074 or CML21UKEX1102
Zone 2 and 22 Variant CML 17ATEX4149 & IEC Ex CML17.0074 or CML21UKEX4101
Zone 21 Dust only Variant CML 18ATEX3161 & IEC Ex CML18.0087 or CML21UKEX3107
This installation guide provides instructions for installing the SPARTAN HP Highbay/ Flood-
light series of explosion protected floodlights.
Overview
Important information
The SPARTAN HP series of explosion protected floodlights/highbay are specialist devices,
certified for use in specific operating environments.
The units must be installed in accordance with these instructions, must be correctly certified
for the specific operating environment and must be installed by suitably qualified personnel.
If you have any queries about the installation or the certification of the unit – please contact
Raytec for immediate assistance and advice.
SPARTAN
1
Safety Instructions
2
Installation
3
Maintenance
4
Technical Specification
5
Trouble Shooting

Advertisement

loading

Summary of Contents for Raytec SPARTAN SPX

  • Page 1 The units must be installed in accordance with these instructions, must be correctly certified for the specific operating environment and must be installed by suitably qualified personnel. If you have any queries about the installation or the certification of the unit – please contact Raytec for immediate assistance and advice.
  • Page 2: Safety Instructions

    2. The line diagrams below are for guidance only – units may be mounted in any orientation 4. If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec. Mounting HP SPARTAN Unit – Floodlight Application 5.
  • Page 3 Mounting SPARTAN Unit – Highbay Application Typical wiring diagram Ex 'd' Enclosure Ex 'e' Junction Box LED1+ LED1- LED2- LED1+ LED2+ LED1- LED2- Ex d LED2+ LED DRIVER #1 Assembly LED- EQUI LED+ LED DRIVER #2 LED- LED+ EQUI 422 (16.6") 353 (13.9") 33 (1.3") LED1+ LED1-...
  • Page 4: Maintenance

    Total Harmonic Distortion (230Vac, full load) ≤3% enclosure, the gasket is located in the machined groove, all replacement gaskets must be supplied via Raytec IP Rating IP66 Disposal of packaging, SPARTAN units and old LED assemblies/power supplies...
  • Page 5: Troubleshooting

    4.1 DALI Wiring Instructions Maximum cable length L in m Max number of fittings allowed per MCB Cross section in mm SPZ/SPX-HP10K SPZ/SPX-HP15K SPZ/SPX-HP20K SPZ/SPX-HP25K 25°C 50°C 75°C MCB Type Rating (120W Version) (180W Version) (240W Version) (300W Version) 0.14 0.50 0.75 1.00...
  • Page 6 EN 60079-0 : 2018 EN 60079-1 : 2014 EN60079-7 : 2015 + A1 2018 Raytec Ltd. declares under our sole responsibility that the product(s) listed below conform with the relevant provisions of directive 2014/34/EU of 20 April 2016 and EN 60079-15 : 2019...
  • Page 7 UK / Europe T: +44 (0) 01670 520055 hazsales@raytecled.com Americas T: +1 613 270 9990 ushazsales@raytecled.com www.raytecled.com...

This manual is also suitable for:

Spartan spz