Advertisement

Quick Links

User Manual
———
E217

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E217 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dnake E217

  • Page 1 User Manual ——— E217...
  • Page 3 REMARK Please follow the user manual for correct installation and testing. If there is any doubt please call our tech-supporting and customer center. Our company applies ourselves to reformation and innovation of our products. No extra notice for any change. The illustration shown here is only for reference. If there is any difference, please take the actual product as the standard.
  • Page 4: Table Of Contents

    CATALOG PRODUCT FEATURE ..........1 TECHNICAL PARAMETER ........1 PACKAGE CONTENT ..........2 OVERVIEW .............. 3 BASIC OPERATION ..........4 DEVICE SETTING ..........13 WEB SETTING ............20 SYSTEM DIAGRAM ..........36 DEVICE WIRING ............37 INSTALLATION ............40 TROUBLESHOOTING ........... 42 SAFETY INSTRUCTION ........43...
  • Page 5: Product Feature

    PRODUCT FEATURE 7-inch capacitive touch screen Powered by PoE or power adapter (DC12V/2A) Dual network ports optional Support WiFi Support monitoring 8 IP cameras Support TF card TECHNICAL PARAMETER System: Linux Front Panel: Plastic Power Supply: PoE (802.3af) or DC 12V/2A Standby Power: 2 W Rated Power: 9 W Ethernet Port: 1 x RJ45, 10/100 Mbps adaptive...
  • Page 6: Package Content

    PACKAGE CONTENT MODEL: E217 E217 Wiring Cover PM4×20 (2 pcs) Diode (8 pcs) Wires Desktop Stand Quick Start Guide (Optional)
  • Page 7: Overview

    OVERVIEW...
  • Page 8: Basic Operation

    BASIC OPERATION 1. Call Go to Dial and enter Building number + Building + Unit number + Unit + Room number + dial icon to call Indoor Monitor (such as 1 + Building + 1 + Unit + 1111 + Dial button). Or you can press Concierge here to call Master Station. 2.
  • Page 9 Click + icon on Outgoing page. Users can send message to Indoor Monitor or Master Station. Before sending message, users need to fill in the receiver’s IP address on Indoor Monitor webpage (Concierge IP in Intercom > Call column). 4. DND Click DND icon on the right upper corner to enable do not disturb function.
  • Page 10 5.1.ON/OFF Click Out, Home, or Sleep icon to activate the scene for alarm sensors, the icon on the main interface will light up with a beep sound; OFF: Click OFF to disable scene; 5.2.Zone Type:  Normal: When users enable an alarm scene on the On/Off page, Normal type alarm zone will be activated after activation time.
  • Page 11 Station. o But sometimes users don't want to send the alarm to Master Station (maybe alarm by mistake), users can set the Delay time, so they can cancel the alarm in the Indoor Monitor during this Delay time (PIR, Door, Window);...
  • Page 12 Activation Time: Only after activation time, will scene be activated. Activation time is only effective for Normal type (NONE, 30s, 40s, 60s, 100s, and 300s); Mode: Tick to link sensors to Out, Home, or Sleep scene; 5.4.Setup Old: Current security password of the Device (Default 123456);...
  • Page 13 Once the camera is successfully added, you can preview the video. 8. Phonebook Click phone Book. Or go to Dial > Phonebook. Select the name on the phonebook and press dial button to call.
  • Page 14 Only when the license is filled in Internet-connected Indoor Monitor, QR code will be available. 10. Elevator Press the Elevator icon to control elevator (DNAKE Elevator Control Module is needed). 11. Add More Indoor Monitors Keep Building, Unit, Apartment No., Sync the same as other Indoor Monitors, and...
  • Page 15 you must have one Indoor Monitor’s Device number is 0 and keep it online because 0 here stands for the main one. Or go to Indoor Monitor’s webpage and find Ex Phone in Intercom > Call. Users can directly extend to more Indoor Monitors by filling in sip:IP address (6 Max) such as sip:192.168.68.90.
  • Page 16 13. SOS Users can press SOS icon on the right upper corner to send SOS to Master Station. Users can set the trigger time length on the webpage. If the time is set to 3s, users need to press the SOS icon for 3s to send out SOS in case of a wrong operation alarm.
  • Page 17: Device Setting

    DEVICE SETTING 1. General 1.1. Display Brightness: Screen brightness adjustment; Sleep Time: Screen sleep time (15s, 30s, 1min, 2mins, 5mins, 20mins, 30mins); Screen Lock: The screen will be locked after screen off timeout (Unlock password is security password. The default password is 1234); 1.2.
  • Page 18 Hang Up After Unlocking: Hang up automatically after unlocking doors. 1.3. Date & Time Auto: Enable to synchronize computer time; Date&Time: Date and time can be set manually; Time Zone: A region that observes a uniform standard time; 12H/24H: Select 12H or 24H format to display on the device;...
  • Page 19 WLAN: Enable to use WiFi; SSID: Select WiFi to connect; Status: The status of WiFi. 3. DND DND: DND is disabled by default. Whole Day: when DND is enabled, it will reject calls for the whole day. Duration: when DND is enabled, it will reject calls during this time.
  • Page 20 5. Reboot You can click “OK” to reboot indoor monitor. 6. Version Firmware Version: Firmware version of the device; Current IP address of the device; MAC: MAC address of the device; WiFi IP: Current WiFi IP address of the device; SIP: Status of SIP registration of the device;...
  • Page 21 DHCP: Enable DHCP (Dynamic Host Configuration Protocol) to dynamically distributing network configuration parameters; Configure Static IP address to manually distributing network configuration parameters; Mask: Subnet mask; Gateway: A component that is part of two networks, which use different protocols; DNS: Domain Name Server of the device;...
  • Page 22 SIP: Enable to use SIP; Display Name: Display name of SIP account; Register Name: Register Name of SIP account; Username: Username of SIP account; Password: Password of SIP account; SIP Server Host: Directly fill in SIP server’s address e.g., 192.168.68.90; The default port is 5060;...
  • Page 23 Reset: Reset to factory default;...
  • Page 24: Web Setting

    WEB SETTING Connect Indoor Monitor and PC to a network switch in the same LAN. You can enter the IP address of Indoor Monitor in the web browser search bar and log in with the default account (admin) and password (123456). This is where you can configure the device.
  • Page 25 Model: Model of the device; Firmware Version: Firmware version of the device; MAC Address: MAC address of the device; Framework: Framework of the device; UI of the device; DHCP: Status of DHCP; IP Address: Current IP address of the device; Mask: Subnet mask of the device;...
  • Page 26 ault password is 1234); Language: 16 languages supported (简体中文, English, 繁體 中文, ‫ ,ִ ר בִ ר ית‬Deutsch, Español, Türk, Tiếng Việt, Nederlands, Português, Polski, Русский, ‫ ,عربي‬Fr ançais, Italiano, slovenský); System Vol: Volume of System can be set from 1 to 6. Volum e 6 is the maximum volume (Key tone);...
  • Page 27 NTP URL: Network Time Protocol (NTP) is a protocol used t o synchronize NTP time; Time Zone: A region that observes a uniform standard time; 12H/24H: Select 12H or 24H format to display on the devic Date Format: 3 time formats supported (YYYY-MM-DD, DD-M M-YYYY, MM-DD-YYYY);...
  • Page 28 User Confirm Password: Confirm security password of the Device; Web Old Password: Current administrator password of the web (Def ault 123456); Web New Password: New administrator password of the web; Web Confirm Password: Confirm administrator password of the web; 1.5.General > System The system column is designed for factory default and device reboot.
  • Page 29 should be different. The Device number can be from 0 to 9. But you must have one Indoor Monitor’s Device number is 0 and keep it online because 0 here stands for the main one. Building: Number of the building (Range: 1-999); Unit: Number of the unit (Range: 0-99);...
  • Page 30 DHCP: Enable DHCP (Dynamic Host Configuration Prot ocol) to dynamically distribute network configurat ion parameters; IP Address: Configure Static IP address to manually distribut e network configuration parameters; Mask: Subnet mask; Gateway: A component that is part of two networks, which use different protocols;...
  • Page 31 SIP: Enable to use SIP; Display Name: Display name of SIP account; Register Name: Register Name of SIP account; Username: Username of SIP account; Password: Password of SIP account; SIP Server Host: Directly fill in SIP server’s address e.g., 192.168.68.90; The default port is 5060;...
  • Page 32 Call Concierge URL: Fill in the call destination for concierge button or the single button on the device;  IP call: Fill in sip:IP address, e.g., sip:192.168.68.90;  SIP call: Fill in sip:sip account@SIP server address:port, e.g., sip:101@192.168.68.90:5060; Multicast: Enable to receive broadcast from Master Station; Message IP: Fill in the message receiver’s (Indoor Monitor or Master Station) IP address.
  • Page 33 Whitelist: Enable whitelist to block other calls outside of th e whitelist. For example, Ana is in the whitelist b ut Nyree isn’t in it. Ana can call in while Nyree ca n’t; Search: Fill in text inputs to search; Reset: Click reset to clear words in text inputs;...
  • Page 34 Search: Fill in text inputs to search; Reset: Click reset to clear words in text inputs; Delete All: Delete all data on the chart; Export: Export all data on the chart; 3. Security 3.1.Security > Zone Zone column is the setup page for security sensors. Type: ...
  • Page 35 be activated after activation time. o 100 seconds is the default activation time, it means the alarm will be activated after 100 seconds. o After 100s, once sensor is triggered, Indoor Monitor will send this alarm to Master Station. o But sometimes users don't want to send the alarm to Master Station (maybe alarm by mistake), users can set the Delay time, so they can cancel the alarm in the Indoor...
  • Page 36 Activation Time: Only after activation time, will scene be activate d. Activation time is only effective for Normal typ e (NONE, 30s, 40s, 60s, 100s, and 300s); Mode: Tick to link sensors to Out, Home, or Sleep scen 4. Advanced 4.1.Advanced >...
  • Page 37 Bell is for doorbell); Local Relay Delay: The length of unlock delay time (1-9s); Unlock Button 1-3: Enable or disable relays for unlock buttons; Name: Customize name for unlock button; Type: Type 1-3: 3 types of unlock way are optional (Local Relay/DTMF/HTTP) HTTP——the format is http://192.168.3.119/cgi- bin/webapi.cgi?api=unlock&index...
  • Page 38 Name: Customize name of IPC; IPC URL: Fill in IPC’s RTSP stream; 4.3.Advanced > More More column is for SOS and Wallpaper. SOS: Trigger Time can be set to 0s and 3s. If the time is set to 3s, users need to press the SOS icon for 3s to send out SOS in case of a wrong operation alarm.;...
  • Page 39 Please make sure the picture’s resolution is the same as the device’s and the size of the picture should be lower than 512KB. The format of Picture should be JPG or PNG;...
  • Page 40: System Diagram

    SYSTEM DIAGRAM...
  • Page 41: Device Wiring

    DEVICE WIRING 1. Network (PoE) Single Port: Network (PoE) interface is for the connection with PoE switch or other network switch. Dual Port: 1. RJ45 interface is for providing the power and network for Villa Station (special version) directly from this Indoor Monitor, so Villa Station doesn't need extra power adaptor.
  • Page 42 2. Power The power interface of Indoor Monitor connects to 12V DC power. 3. Relay Output Warning! 1. When connecting to an inductive load device such as a relay or electromagnetic lock, you are recommended to use a diode 1A/400V (included in the accessories) in anti- parallel with the load device to absorb inductive load voltage peaks.
  • Page 43 5. Siren/Alarm Interface of alarm zones connects with normally-open or normally-closed switch. When the alarm zone is triggered, it will output 12V/100mA power.
  • Page 44: Installation

    INSTALLATION Surface Mounting-86 Mounting Box Product size: 195 × 130 × 14.5 mm...
  • Page 45 Desktop Mounting Product size: 195 × 130 × 14.5 mm Tips: The camera should be 1450~1550mm above the ground. The camera at this height can capture human face perfectly.
  • Page 46: Troubleshooting

    TROUBLESHOOTING The Indoor Monitor cannot start up or power off automatically. Check whether it has power-failure, and power it on again  The Indoor Monitor display screen is too dim. Check whether the brightness and contrast settings of screen are correct. ...
  • Page 47: Safety Instruction

    SAFETY INSTRUCTION In order to protect you and others from harm or your device from damage, please read the following information before using the device. Do not install the device in the following places:  Do not install the device in high-temperature and moist environment or the area close to ...
  • Page 48 V1.2 EASY SMART INTERCOM SOLUTIONS...

Table of Contents