Hide thumbs Also See for 280SD-C12:

Advertisement

Quick Links

User Manual
———
DNAKE 280SD-C12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 280SD-C12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dnake 280SD-C12

  • Page 1 User Manual ——— DNAKE 280SD-C12...
  • Page 3 REMARK Please follow the user manual for correct installation and testing. If there is any doubt please call our tech-supporting and customer center. Our company applies ourselves to reformation and innovation of our products. No extra notice for any change. The illustration shown here is only for reference. If there is any difference, please take the actual product as the standard.
  • Page 4: Table Of Contents

    CATALOG PRODUCT FEATURE ..........1 TECHNICAL PARAMETER ........1 PACKAGE CONTENT ..........2 OVERVIEW .............. 3 BASIC OPERATION ..........5 WEB SETTING ............6 SYSTEM DIAGRAM ..........18 DEVICE WIRING ........... 19 INSTALLATION ............21 TROUBLESHOOTING ........... 23 SAFETY INSTRUCTION ........24...
  • Page 5: Product Feature

    PRODUCT FEATURE 1. Powered by PoE or power adapter (DC12V/2A) 2. Open the door by IC card (20,000 users) 3. Support SIP 2.0 protocol, easy integration with other SIP devices TECHNICAL PARAMETER Power Supply: PoE (802.3af) or DC 12V/2A Standby Power: 1.5 W Rated Power: 3 W Resolution: 1280 x 720 Working Temperature: -40℃...
  • Page 6: Package Content

    PACKAGE CONTENT MODEL: 280SD-C12 (Surface Mounting) 280SD-C12 PM4×20 (2 pcs) FM5×5 (1 pcs) Rear Cover Wires Quick Start Guide MODEL: 280SD-C12 (Flush Mounting) 280SD-C12 PM4×20 (4 pcs) Rear Cover Wires Quick Start Guide...
  • Page 7: Overview

    OVERVIEW...
  • Page 9: Basic Operation

    BASIC OPERATION 1. Call and Monitor 1.1. Call Indoor Monitor In standby mode, press button on Villa Station to call Indoor Monitor. During the call, press button on Villa Station again to end the call. If the call fails or Indoor Monitor is busy, Villa Station will make a beep sound.
  • Page 10: Web Setting

    IP address of Door Station in the web browser search bar and log in with the default account (admin) and password (123456). This is where you can configure the device. To get the IP address, you can search by DNAKE Remote Upgrade Tool installed in the same LAN with the devices. 1. General 1.1.
  • Page 11 Model: Model of the device; Firmware Version: Firmware version of the device; MAC Address: MAC address of the device; Framework: Framework of the device; UI of the device; DHCP: Status of DHCP; IP Address: Current IP address of the device; Mask: Subnet mask of the device;...
  • Page 12 Language: 16 languages supported (简体中文, English, 繁體 中文, ‫ ,ﬠ ִ בר ִ ית‬Deutsch, Español, Türk, Tiếng Việt, Nederlands, Português, Polski, Русский, ‫,ﻋرﺑﻲ‬ Français, Italiano, slovenský); Resolution: 3 resolutions supported (320 × 240, 640 × 480, 1280 × 720); Intercom: Volume of Intercom can be set from 1 to 6;...
  • Page 13 Web Old Password: Current administrator password of the web (Default 123456); Web New Password: New administrator password of the web; Web Confirm Password: Confirm administrator password of the web; 1.5. General > System The system column is designed for data backup and restore, firmware upgrade, factory default, device reboot, packet capture, logs capture, and obtaining UI screenshots.
  • Page 14 Backup&Restore: Backup all setting and restore settings; Upgrade: Upgrade equipment; Reset: Reset to factory settings; Reboot: Reboot the device; Packet Capture: Capturing packets can help developers reproduce positioning problems; Logs: Device logs; 2. Intercom 2.1. Intercom > Device Numbers here are basic settings for making a call to Indoor Monitor. For Door Station, the building and unit number should be the same as those in Indoor Monitor.
  • Page 15 Building: Number of the building (Range: 1-999); Unit: Number of the unit (Range: 1-99); Room: Number of the room (Range: 0-9899); Device No: Number of the device (Range: 1-9); 2.2. Intercom > Network The device network can be set to either DHCP or a static IP address. CMS parameters should be configured here when you try to register this device to CMS.
  • Page 16 DHCP: Enable DHCP (Dynamic Host Configuration Protocol) to dynamically distribute network configuration parameters; IP Address: Configure Static IP address to manually distribute network configuration parameters; Mask: Subnet mask; Gateway: A component that is part of two networks, which use different protocols; DNS: Domain Name Server of the device;...
  • Page 17 Transfer Protocol: Transfer Protocol (UDP, TCP, TLS); Video Payload: Video payload range is 96-127; 2.4. Intercom > Ring Group Ring group is for setting up SIP calls or call mode. Concierge button, the length of the call and ring time can also be configured here. Mode: 2 modes supported (one by one, all at once);...
  • Page 18 Search: Fill in text inputs to search; Reset: Click reset to clear words in text inputs; Delete All: Delete all data on the chart; Export: Export all data on the chart; 3. Access 3.1. Access > Access Control Relays, and access cards can be configured here. Relay 1: 1 relay supported;...
  • Page 19 DTMF: Dual-tone multi-frequency signaling (Relay1: #, Relay2:0, relay3: *); Unlock Delay: The length of unlock delay time (1-9s); Unlock Time: The length of unlock time (1-9s); Master Card: Click read to add Master card to manage cards; Swipe to arm/disarm: Enable to let security alarm (on and off) keep pace with registered cards (lock and unlock);...
  • Page 20 Search: Fill in text inputs to search; Reset: Click reset to clear words in text inputs; Delete All: Delete all data on the chart; Export: Export all data on the chart; 4. Advanced 4.1. Advanced > Video Real-time video from IP cameras can be obtained by filling in its URL (RTSP). On the talking interface of Indoor Monitor, you can click the little keyboard icon to switch to IP cameras’...
  • Page 21 RTSP Feed: 4 IP cameras supported to switch while talking on Indoor Monitor; URL: IP camera’s URL; 4.2. Advanced > More More column is for ONU Penetration. ONU Penetration: Enable to prevent ONU from banning multicast;...
  • Page 22: System Diagram

    SYSTEM DIAGRAM...
  • Page 23: Device Wiring

    DEVICE WIRING 1. Network (PoE) Standard RJ45 interface used to connect to the Master Station, Indoor Monitor and/or other network equipment via network switch. PSE shall comply with IEEE 802.3at (PoE+) and its output power not less than 30W and its output voltage not less than 50V. 2.
  • Page 24 Warning! 1. When connecting to an inductive load device such as a relay or electromagnetic lock, you are recommended to use a diode 1A/400V (included in the accessories) in anti- parallel with the load device to absorb inductive load voltage peaks.
  • Page 25: Installation

    INSTALLATION Surface Mounting-86 Mounting Box Product size: 170 × 84.5 × 31 mm...
  • Page 26 Flush Mounting Product size: 190 × 95 × 27 mm Surface Mounting size: 180 × 85 × 45 mm Mounting hole size: 185 × 90 × 52 mm Tips: 1. The camera should be 1450~1550mm above the ground. The camera at this height can capture human face perfectly. 2.
  • Page 27: Troubleshooting

    TROUBLESHOOTING The Indoor Monitor cannot start up or power off automatically. Check whether it has power-failure, and power it on again  The Indoor Monitor display screen is too dim. Check whether the brightness and contrast settings of screen are correct. ...
  • Page 28: Safety Instruction

    SAFETY INSTRUCTION In order to protect you and others from harm or your device from damage, please read the following information before using the device. Do not install the device in the following places:  Do not install the device in high-temperature and moist environment or the area close to ...
  • Page 29 V1.1 EASY SMART INTERCOM SOLUTIONS...

Table of Contents