Summary of Contents for Dnake 280SD-C12

  • Page 2 REMARK Please follow the user manual for correct installation and testing. If there is any doubt please call our tech-supporting and customer center. Our company applies ourselves to reformation and innovation of our products. No extra notice for any change. The illustration shown here is only for reference.
  • Page 3: Table Of Contents

    CATALOG Technical Parameters..........1 Package Contents ............1 Basic Function............2 Pictures..............2 Basic Operations............3 Web Settings ............4 System Configuration ..........11 System Diagram .............12 Installation ..............14 Troubleshooting .............16 Safety Instructions ..........17...
  • Page 4: Technical Parameters

    ◇ Rated power: 3W ◇ Standby power: 1.5W ◇ Camera resolution: 1280x720 ◇Working temperature -40~+55℃ ◇Storage temperature: -40~+70℃ ◇Working humidity: 10%-90% (non-condensing) PACKAGE CONTENTS MODEL: 280SD-C12(Flush Mounting) Screw Screw Wrench Door Station Quick Start Guide MODEL: 280SD-C12(Surface Mounting) Door Station...
  • Page 5: Basic Function

    BASIC FUNCTION ◇Call indoor monitor by one button; ◇Support unlocking by IC access control card or password; ◇IC card information can be registered on door station. Registration information of max. 100,000 IC cards can be stored; ◇Support unlocking by Exit button and door magnetic detection; ◇Support LED light for night vision;...
  • Page 6: Basic Operations

    BASIC OPERATIONS 1. Call indoor monitor In standby mode, press the call button on door station to call indoor monitor. During the call, press the call button on door station again to end the call. If the call fails or indoor monitor is busy, door station will emit a beep.
  • Page 7: Web Settings

    WEB SETTINGS Connect door station to PC through the switch. Input IP address of door station in the web browser of PC (The IP addresses of PC and door station must be in the same network segment. Default IP address is 192.168.68.90), then input user name and password (default user name is "admin"...
  • Page 8 DHCP: dynamic IP function. IP address: for the same system on the same network segment, IP address can not be repeated. Subnet mask: the original subnet mask is 255.255.255.0, which normally doesn't need to be changed. Default gateway: according to the project site IP network allocation DNS: it refers to IP address of the DNS server Server IP: IP address of digital management software installed in the management center computer...
  • Page 9 System volume: adjust the system volume with 6 levels for selection. Video size: 320x240, 640x480 or 1280x720. Call forwarding: the call can be made one by one or simultaneously. After the setup is completed, click the icon "Submit" to enable the 3.Access Settings Click the icon "Access"...
  • Page 10 Then register the user card. The user should swipe the admin card first. The system emits a beep. Then place the card to be registered near the card reader area within 10 seconds. When the system gives an indication tone, it means that the user card is registered successfully. When registering the user card, the card to be registered should be swiped 10 seconds after the admin card is swiped.
  • Page 11 5.Call Forwarding Click the icon "Forward" on the left side of the page to enter the interface as shown below: The room number can be bound with the telephone number. When a visitor calls but there is no answer within 25 seconds, the system will automatically forward the call to the phone.
  • Page 12 Quick Call: Check the box to enable this function. It refers to the call to master station. Enter the SIP address of specified master station device in the box after URL. The device can be indoor monitor or SIP phone of other manufacturers.
  • Page 13 7.Other Settings Click the icon "Others" on the left side of the page to enter the interface as shown below: Click Reboot to restart the system. 8. Logout Click the icon "Logout" on the left side. In next page, click the icon "Submit" to log out the system.
  • Page 14: System Configuration

    SYSTEM CONFIGURATION System Configuration CAT-5e+RVV2 CAT-5e+RVV2 Terminal *1.0 CAT-5e Audio extension (optional) CAT-5e Audio extension (optional) Terminal *1.0 Power 220V Power 220V Audio extension (optional) Audio extension (optional) Network Switch Network Switch RVV2*0.5 RVV2*0.5 Terminal Terminal 220V 220V Power Power CAT-5e CAT-5e Audio extension (optional)
  • Page 15: System Diagram

    Peripheral Interface Network 12V GND 485+485- EXIT DS DIN DC12V RJ45 280SD-C12 1. RS485 It can connect to the equipment with RS485 interface. RS485 interface can output 12V/100mA power. Connection of +12V isn't require if it is unused. +12V +12V...
  • Page 16 3. Network Connect to management center, indoor monitor or other network device through. CAT-5e Network interface 4. RS485/Switching Value Output/Exit/Door-detector +12V +12V RS485 equipment 485+ 485+ 485- 485- Normally-closed connection of relay Common port of relay Normally-open connection of relay EXIT Exit button Exit...
  • Page 17: Installation

    INSTALLATION MODEL: 280SD-C12(Surface Mounting) Rear Cover 86 Built-in Door Station Product size: 170x84.5x31mm Installation Instructions: [Suggestion]: During the installation, the camera should be 1450〜1550mm above the Wall ground. The camera tether for photographing human face should be the top priority.
  • Page 18 MODEL: 280SD-C12(Flush Mounting) Built-in Box Door Station Drain hole Product size: 190x95x27mm Built-in box size:180X85X45mm Trepanning size:185x90x52mm Installation Instructions: [Suggestion]: During the installation, the camera should be 1450〜1550mm above the Wall ground. The camera tether for photographing human face should be the top priority.
  • Page 19: Troubleshooting

    TROUBLESHOOTING Some common failures and troubleshooting methods are listed for your reference. In case of failure which cannot be repaired, do not disassemble or repair the product by yourself. Please contact the after-sales service department. When unit panel or wall panel fails to call indoor monitor: When setting door station, please make sure building No.
  • Page 20: Safety Instructions

    SAFETY INSTRUCTIONS In order to protect you and others from harm or your device from damage, please read the following information before using the device. Do not install the device in the following places: Do not install the device in high-temperature and moist environment or the area close to magnetic field, such as the electric generator, transformer or magnet.