Dnake S215 User Manual

Dnake S215 User Manual

Door station
Hide thumbs Also See for S215:

Advertisement

Quick Links

User Manual
———
DNAKE S215

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S215 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dnake S215

  • Page 1 User Manual ——— DNAKE S215...
  • Page 3 REMARK Please follow the user manual for correct installation and testing. If there is any doubt please call our tech-supporting and customer center. Our company applies ourselves to reformation and innovation of our products. No extra notice for any change. The illustration shown here is only for reference. If there is any difference, please take the actual product as the standard.
  • Page 4: Table Of Contents

    CATALOG PRODUCT FEATURE ..........1 TECHNICAL PARAMETER ........1 PACKAGE CONTENT ..........2 OVERVIEW .............. 3 BASIC OPERATION ..........4 DEVICE SETTING ........... 6 WEB SETTING ............9 SYSTEM DIAGRAM ..........23 DEVICE WIRING ........... 24 INSTALLATION ............26 TROUBLESHOOTING ........... 28 SAFETY INSTRUCTION ........
  • Page 5: Product Feature

    PRODUCT FEATURE 1. Induction loop for hearing impaired 2. Braille dot for visually impaired 3. 3 output relays for door locks 4. Tamper alarm 5. Support IC (13.56MHz) & ID (125kHz) card, PIN code, NFC TECHNICAL PARAMETER Power Supply: PoE (802.3af) or DC 12V/2A Standby Power: 1.5 W Rated Power: 9 W Resolution: 480 x 272...
  • Page 6: Package Content

    PACKAGE CONTENT MODEL: S215 (Surface Mounting) Sealing Plug of S215 Wiring Cover Junction Pressing PWM3×8×7 (4 pcs) Wiring Port Screw Fixing Seat Rear Cover PA4×25 (4 pcs) FM3×4.5 (2 pcs) Hang rope (4 pcs) Wrench Screw Diode (3 pcs) Quick Start Guide...
  • Page 7: Overview

    OVERVIEW...
  • Page 8: Basic Operation

    BASIC OPERATION 1. Call and Monitor 1.1. Call Indoor Monitor In standby mode, press room numbers + #/dial on Door Station to call Indoor Monitor. During the call, press * on Door Station again to end the call. If the call fails or Indoor Monitor is busy, Door Station will make a beep sound.
  • Page 9 Step 2: And then tap other cards immediately. Other cards you have tapped will be deleted; Step 3: Tap the admin card again to finish. 5.3. Delete all other cards Tap the admin card five times. All the other cards will be deleted. Tips: The admin card can only be used to manage cards.
  • Page 10: Device Setting

    DEVICE SETTING Connect Door Station and PC to a network switch in the same LAN. You can enter the admin settings of Door Station by pressing # twice and entering default password (123456). This is where you can configure the device. 1.
  • Page 11 Volume: Volume of System can be set from 1 to 6; Size: 3 resolutions supported (320 × 240, 640 × 480, 1 280 × 720); 2. Network Settings The device network can be set to either DHCP or a static IP address. CMS parameters should be configured here when you try to register this device to CMS.
  • Page 12 Password: PIN code for unlock (Default 0000); Elev Refer: The floor Door Station is installed at (Range: -9-99); 4. About System You can find basic information displayed in About System. Firmware Version: Firmware version of the device; Current IP address of the device; MAC: MAC address of the device;...
  • Page 13: Web Setting

    (admin) and password (123456). This is where you can configure the device. For getting the IP address, you can search by DNAKE Remote Upgrade Tool which is installed in the same LAN with the devices. 1. General 1.1.
  • Page 14 Model: Model of the device; Firmware Version: Firmware version of the device; MAC Address: MAC address of the device; Framework: Framework of the device; UI of the device; MCU: MCU of the device; DHCP: Status of DHCP; IP Address: Current IP address of the device; Mask: Subnet mask of the device;...
  • Page 15 Language: 16 languages supported (简体中文, English, 繁體 中文, ‫ ,ﬠ ִ בר ִ ית‬Deutsch, Español, Türk, Tiếng Việt, Nederlands, Português, Polski, Русский, ‫ ,ﻋرﺑﻲ‬Fr ançais, Italiano, slovenský); Resolution: 3 resolutions supported (320 × 240, 640 × 480, 1 280 × 720); Intercom: Volume of Intercom can be set from 1 to 6;...
  • Page 16 The System password is for the administrator to log in settings on the device while the Web password is for the administrator to log in settings on the web. The default password for both of them is 123456. System Old Password: Current administrator password of the Device (D efault 123456);...
  • Page 17 Backup&Restore: Backup all setting and restore settings; Upgrade: Upgrade equipment; Reset: Reset to factory settings; Reboot: Reboot the device; Packet Capture: Capturing packets can help developers reproduc e positioning problems; Logs: Device logs; Screenshot: Screenshot device interface; 2. Intercom 2.1. Intercom > Device...
  • Page 18 Numbers here are basic settings for making a call to Indoor Monitor. For Door Station, the building and unit number should be the same as those in Indoor Monitor. For Villa Station with one button, the building, unit, and room number should be the same as those in Indoor Monitor.
  • Page 19 DHCP: Enable DHCP (Dynamic Host Configuration Prot ocol) to dynamically distribute network configurat ion parameters; IP Address: Configure Static IP address to manually distribut e network configuration parameters; Mask: Subnet mask; Gateway: A component that is part of two networks, which use different protocols;...
  • Page 20 SIP: Enable to use SIP; Display Name: Display name of SIP; Register Name: Register Name of SIP; Username: Username of SIP; Password: Password of SIP; SIP Server Host: SIP Server Host of SIP; the default port is 5060; Outbound Proxy: Outbound Proxy of SIP;...
  • Page 21 Mode: 2 modes supported (one by one, all at once); URL: URL of the concierge button; Dial Mode: 2 dial modes supported (Normal, Repeat); Ring Time: The ring will be ended automatically after a perio d of time (10s, 20s, 35s, 45s, 60s, 90s, 120s) Call Time: The call will be ended automatically after a perio d of time (120s, 300s, 600s, 1200s, 1800s);...
  • Page 22 Reset: Click reset to clear words in text inputs; Delete All: Delete all data on the chart; Import: Import all data to the chart; Export: Export all data on the chart; 2.6. Intercom > Call Logs All call logs can be checked here. Search: Fill in text inputs to search;...
  • Page 23 Relay 1-3: 3 relays supported; DTMF: Dual-tone multi-frequency signaling (Relay1: #, Relay2:0, relay3: *); Unlock Delay: The length of unlock delay time (1-9s); Unlock Time: The length of unlock time (1-9s); Dry Contact Input 1-3: 3 modes of dry contact inputs are supported (Exi t Button, Door Sensor, Fire Linkage);...
  • Page 24 Search: Fill in text inputs to search; Reset: Click reset to clear words in text inputs; Delete All: Delete all data on the chart; Export: Export all data on the chart; 3.3. Access > Unlock Logs All unlock logs can be checked here.
  • Page 25 Search: Fill in text inputs to search; Reset: Click reset to clear words in text inputs; Delete All: Delete all data on the chart; Export: Export all data on the chart; 4. Advanced 4.1. Advanced > Video Real-time video from IP cameras can be obtained by filling in its URL (RTSP). On the talking interface of Indoor Monitor, you can click the little keyboard icon to switch to IP cameras’...
  • Page 26 Tamper Alarm: Enable to use Tamper alarm; ONU Penetration: Enable to prevent ONU from banning multicast; Call Mode: Switch to RoomNo. calls or SIP calls;...
  • Page 27: System Diagram

    SYSTEM DIAGRAM...
  • Page 28: Device Wiring

    DEVICE WIRING 1. Network (PoE) Standard RJ45 interface used to connect to the master station, indoor monitor, and/or other network equipment via a network switch. PSE shall comply with IEEE 802.3at (PoE+) and its output power not less than 30W and its output voltage not be less than 50V. 2.
  • Page 29 Connect to the lock module (an independent power supply is necessary for the lock). Warning! 1. When connecting to an inductive load device such as a relay or electromagnetic lock, you are recommended to use a diode 1A/400V (included in the accessories) in anti- parallel with the load device to absorb inductive load voltage peaks.
  • Page 30: Installation

    INSTALLATION Surface Mounting-86 Mounting Box Product size: 133 × 295 × 41 mm Surface Mounting size: 133 × 295 × 43 mm...
  • Page 31 Flush Mounting Product size: 133 × 295 × 41 Flush Mounting size: 133 × 295 × 63.5 mm Hole-cutting size: 124 × 289 × 56 Tips: The camera should be 1450~1550mm above the ground. The camera at this height can capture human face perfectly.
  • Page 32: Troubleshooting

    TROUBLESHOOTING The Indoor Monitor cannot start up or power off automatically. Check whether it has power-failure, and power it on again  The Indoor Monitor display screen is too dim. Check whether the brightness and contrast settings of screen are correct. ...
  • Page 33: Safety Instruction

    SAFETY INSTRUCTION In order to protect you and others from harm or your device from damage, please read the following information before using the device. Do not install the device in the following places:  Do not install the device in high-temperature and moist environment or the area close to ...
  • Page 34 V1.3 EASY SMART INTERCOM SOLUTIONS...

Table of Contents