MECHANICAL INSTALLATION GUIDELINES
L1
L2
L3
A
KA
Avg
SET
Scroll
101.00
FRONT VIEW
All dimensions are in mm
1. Prepare the panel cutout with proper dimensions as show
above.
2. Fit the unit into the panel with the help of clamp given.
3. The equipment in its installed state must not come in close
proximity to any heating source, caustic vapors, oils steam,
or other unwanted process by products.
4. Use the specified size of crimp terminal (M3.5 screws) to
wire the terminal block. Tightening the screws on the
terminal block using the tightening torque of the range of
0.5 N.m.
5. Do not connect anything to unused terminals.
WARNING GUIDELINES
WARNING : Risk of electric shock.
1. To prevent the risk of electric shock power supply to the
equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is
being supplied.
2. To reduce electromagnetic interference, use wire with adequate
rating and twists of the same of equal size shall be made with
shortest connection.
3. Cable used for connection to power source, must have a cross
2
section of 1mm or greater. These wires should have insulations
capacity made of at least 1.5kV.
4. A better anti-noise effect can be expected by using standard
power supply cable for the instrument.
SAFETY PRECAUTION
!
All safety related codifications, symbols and instructions
that appear in this operating manual or on the equipment must
be strictly followed to ensure the safety of the operating
personnel as well as the instrument.
If all the equipment is not handled in a manner specified
by the manufacturer, it might impair the protection provided
by the equipment.
Read complete instructions prior to installation
and operation of the unit.
WARNING : Risk of electric shock.
AVF 133-M1
V
LL
V
LN
Hz
PS
2.50
54.00
RIGHT SIDE VIEW
Panel Cutout
92
MAINTENANCE
1. The equipment should be cleaned regularly to avoid blockage
of ventilating parts.
2. Clean the equipment with a clean soft cloth. Do not use
isopropyl alcohol or any other cleaning agent.
3. Fusible resistor must not be replaced by operator.
WIRING DIAGRAM
3 Phase - 4Wire
Y
S2
S1
S1
S2
R
20
20
19
19
18
18
16
16
17
17
L
L
L
L
1
1
2
2
S
S
S
S
S
S
S
S
1
1
2
2
1
1
AVF 133-M1-E3-00
AVF 133-M1-E3-00
Voltage:
Voltage:
CAT III
CAT III
(L-L): 50-550V AC
(L-L): 50-550V AC
(L-N): 30-320V AC
(L-N): 30-320V AC
Made in India
Made in India
Current: 0.5 To 5A AC
Current: 0.5 To 5A AC
100
100
CT Selection:
CT Selection:
270V AC/DC
270V AC/DC
!
!
5/5 to 9999/5
5/5 to 9999/5
50/60 Hz, 4VA
50/60 Hz, 4VA
MODBUS
MODBUS
L
L
N
N
B+
B+
A-
A-
5
5
1
1
2
2
3
3
4
4
3 Phase - 3Wire
Y
S2
S1
S1
S2
R
20
20
19
19
18
18
17
17
16
16
L
L
L
L
1
1
2
2
S
S
S
S
S
S
S
S
1
1
2
2
1
1
AVF 133-M1-E3-00
AVF 133-M1-E3-00
Voltage:
Voltage:
CAT III
CAT III
(L-L): 50-550V AC
(L-L): 50-550V AC
(L-N): 30-320V AC
(L-N): 30-320V AC
Made in India
Made in India
Current: 0.5 To 5A AC
Current: 0.5 To 5A AC
100
100
CT Selection:
CT Selection:
270V AC/DC
270V AC/DC
!
!
5/5 to 9999/5
5/5 to 9999/5
50/60 Hz, 4VA
50/60 Hz, 4VA
MODBUS
MODBUS
L
L
N
N
B+
B+
A-
A-
1
1
2
2
3
3
4
4
5
5
1 Phase - 2Wire
S1
S2
20
20
19
19
18
18
17
17
16
16
L
L
L
L
1
1
2
2
S
S
S
S
S
S
1
1
2
2
1
1
AVF 133-M1-E3-00
AVF 133-M1-E3-00
Voltage:
Voltage:
CAT III
CAT III
(L-L): 50-550V AC
(L-L): 50-550V AC
(L-N): 30-320V AC
(L-N): 30-320V AC
Made in India
Made in India
Current: 0.5 To 5A AC
Current: 0.5 To 5A AC
100
100
CT Selection:
CT Selection:
270V AC/DC
270V AC/DC
!
!
50/60 Hz, 4VA
50/60 Hz, 4VA
5/5 to 9999/5
5/5 to 9999/5
MODBUS
MODBUS
L
L
N
N
B+
B+
A-
A-
1
1
2
2
3
3
4
4
5
5
S2
S1
B
15
15
14 13
14 13
12
12
11
11
L
L
3
3
S
S
S
S
2
2
1
1
2
2
System:
System:
3Ø-4W / 3Ø-3W / 1Ø-2W
3Ø-4W / 3Ø-3W / 1Ø-2W
Accuracy Class: 0.5
Accuracy Class: 0.5
www.multispanindia.com
www.multispanindia.com
V
V
V
V
V
V
N
N
L
L
L
L
L
L
1
1
2
2
3
3
6
6
7
7
8
8
9
9
10
10
S2
S1
B
15
15
14 13
14 13
12
12
11
11
L
L
3
3
S
S
S
S
2
2
1
1
2
2
System:
System:
3Ø-4W / 3Ø-3W / 1Ø-2W
3Ø-4W / 3Ø-3W / 1Ø-2W
Accuracy Class: 0.5
Accuracy Class: 0.5
www.multispanindia.com
www.multispanindia.com
V
V
V
V
V
V
N
N
L
L
L
L
L
L
1
1
2
2
3
3
6
6
7
7
8
8
9
9
10
10
15
15
14 13
14 13
12
12
11
11
L
L
3
3
S
S
S
S
S
S
2
2
1
1
2
2
System:
System:
3Ø-4W / 3Ø-3W / 1Ø-2W
3Ø-4W / 3Ø-3W / 1Ø-2W
Accuracy Class: 0.5
Accuracy Class: 0.5
www.multispanindia.com
www.multispanindia.com
V
V
V
V
N
N
V
V
L
L
L
L
L
L
1
1
2
2
3
3
6
6
7
7
8
8
9
9
10
10
N
B
Y
R
B
Y
R
N
L
Need help?