  • Page 1 ASSEMBLY AND OPERATION MANUAL ST-11, STD-11 SPEED GATE AND DOUBLE-SIDED SECTION...
  • Page 2: Table Of Contents

    OPERATING CONDITIONS ....................2 TECHNICAL SPECIFICATIONS .................... 5 DELIVERY SET ........................6 Standard delivery set ....................... 6 4.1.1 ST-11 Speed gate ........................6 4.1.2 STD-11 Double-sided section ....................7 Additional equipment to be supplied upon request ............8 DESIGN AND OPERATION ....................8 Main features ........................
  • Page 3: Application

    1 APPLICATION The ST-11 Speed gate (hereinafter referred to as the speed gate) is a blocking device with swing panels designed for regulation of pedestrian flows at checkpoints of administrative buildings, at banks, shops, railway terminals, airports, etc.
  • Page 4 ST-11 Speed gate, STD-11 Double-sided section Figure 1. Overall dimensions of the speed gate with ATG-300 swing panels Figure 2. Overall dimensions of the speed gate with ATG-300H swing panels...
  • Page 5 Assembly and Operation Manual Figure 3. Overall dimensions of the speed gate with ATG-425 swing panels Figure 4. Overall dimensions of the speed gate with ATG-475 swing panels...
  • Page 6: Technical Specifications

    The power supply unit is connected only to the control board located in the Master section (on the Master side of the double-sided section) and marked as ST-11.771. Consumption current and power consumption are given for each product, ST-11 and STD-11, individually.
  • Page 7: Delivery Set

    The type of section top covers is to be chosen by the Customer when placing an order. The following top cover models are available for the ST-11 speed gate section: STC-11M – made of artificial stone with a built-in indication block;...
  • Page 8: Std-11 Double-Sided Section

    ST-11 Speed gate, STD-11 Double-sided section Assembly and installation tools: Mounting kit of the section top cover: M4×16 screw ........................8 spring washer (4) ......................... 8 Mounting kit of the central post indication block: M5×10 screw ........................4 washer (5) ..........................4 spring washer (5) .........................
  • Page 9: Additional Equipment To Be Supplied Upon Request

    FP-11Q.x Front panel with barcode scanner ..........in the required quantity Galvanized M10 anchor with DIN7984 hexagon socket bolt and washer: for the ST-11 Speed gate ....................... 12 for the STD-11 Double-sided section ..................8 Safety stickers (2 pcs in a set): SG1 Yellow circle ................
  • Page 10: Design

    The top covers made of artificial stone (STC-11M and SDC-11M) are outfitted with indication blocks (8). The bottom part of the central post of the Master section (side) features the ST-11.771 speed gate control board (hereinafter, the control board). The PS unit, RC panel (WRC receiver), Fire Alarm device, and DC and CAN connection cables from the Slave section are connected to the control board.
  • Page 11 Assembly and Operation Manual Figure 6. Overall view and design of ST-11 1 – central post; 2 – central post cover plate; 3 – swing panel cover plate; 4 – swing panel; 5 – central post indication block; 6 – section top cover; 7 – section top duct;...
  • Page 12 ST-11 Speed gate, STD-11 Double-sided section Figure 7. Overall view and design of STD-11: 1 – central post; 2 – central post cover plate; 3 – swing panel cover plate; 4 – swing panel; 5 – central post indication block; 6 – section top cover; 7 – section top duct;...
  • Page 13: Rc Panel

    Assembly and Operation Manual 5.2.3 RC panel The overall view of the RC panel is shown in Fig. 8. The RC panel (18) is a small desktop device made of shockproof ABS plastic. The RC panel is designed for speed gate operation in the manual mode, in which the operator sends commands to the equipment.
  • Page 14 ST-11 Speed gate, STD-11 Double-sided section The control board features a microcontroller, which processes the incoming control commands, transferred to the Unlock A, Stop, Unlock B, and Fire Alarm control inputs, monitors the status of optical sensors of swing panel rotation, and generates commands for the motor drive of the speed gate’s swing panels on the basis of the data received.
  • Page 15 Assembly and Operation Manual Table 1. Contact functions of terminal blocks of the control board Terminal Contact Function block +24V External power supply connection X1 (Power) General Unlock A A direction control input Passage denial control input Stop Unlock B B direction control input A direction indication output on the RC panel Led A X2 (RC)
  • Page 16: Control Signal Parameters

    ST-11 Speed gate, STD-11 Double-sided section 5.2.5 Control signal parameters Passage through the speed gate is controlled by sending control signals to the Unlock A, Stop, and Unlock B inputs. The control signal is sending a low-level signal to the Unlock A, Stop, and Unlock B contacts relative to the GND contact.
  • Page 17: Speed Gate Operation Algorithm

    Assembly and Operation Manual Attention! You may change positions of the switches only when the speed gate is turned off. Shift the switch to the OFF position to switch the speed gate to the potential control mode. The control mode will be changed after the speed gate is switched on. Pulse control mode The mode is used to control the speed gate via the RC panel, wireless remote control, and ACS controller whose outputs support the pulse control mode.
  • Page 18: Speed Gate Control Devices

    (opening or closing) is blocked. In the normal control mode (MODE2 jumper is installed, by default), the entire passage zone of the ST-11 speed gate is covered; in the enhanced control mode (MODE2 jumper is removed), the “safe” zone is limited by the width of the installed swing panels.
  • Page 19: Fire Alarm Device

    Assembly and Operation Manual The standard RC-panel orientation in respect of sections is shown in Fig. 12. If the operator’s workplace is located on the opposite side relative to the Master section, it will be more convenient to swap the RC-panel wires that are connected to the Unlock A and Unlock B contacts, as well as to Led A and Led B respectively (Table 4).
  • Page 20: Optional Devices Connected To The Speed Gate

    ST-11 Speed gate, STD-11 Double-sided section 5.4 Optional devices connected to the speed gate The speed gate control board features the following outputs for connection of optional devices: PASS A, PASS B – for connection to ACS controller inputs (Sect. 5.4.1).
  • Page 21: Remote Indication Blocks

    ATG-475 (set of swing panels) ................66×61×8 cm Weight of the transportation boxes (gross): ST-11: box with ST-11/M and ST-11/S sections ............max. 145 kg STD-11: box with the double-sided section ............. max. 105 kg Box with STC-11 (set of section top covers) .............. max. 19 kg Box with SDC-11 (top cover of the double-sided section) ..........
  • Page 22: Safety Requirements

    ST-11 Speed gate, STD-11 Double-sided section 7 SAFETY REQUIREMENTS Installation safety The speed gate shall be installed by the persons that have fully studied this Manual and have been instructed in safety, in compliance with general rules of electrical and installation works.
  • Page 23: Tools And Equipment Required For Installation

    . Insert the anchor sleeves into the holes so that they are flush with the floor surface. Use the cardboard template (included in the ST-11 set) to mark holes; it is also used to mark holes for the STD-11 double-sided sections.
  • Page 24 ST-11 Speed gate, STD-11 Double-sided section Figure 15. Marking layout for installation of the speed gate The hole size in the layout is specified for anchors of the PFG IH 10 SORMAT type; when using other types of anchors, it is necessary to make holes with a diameter and depth required for those.
  • Page 25 Assembly and Operation Manual Figure 16. Marking layout for installation of the speed gate and double-sided section Prepare cable ducts in the floor: Ducts for cabling from external devices (PS unit, RC panel or ACS controller, Fire Alarm • device etc.) – to holes for entry into the Master section and for entry into the Master side of the double-sided section;...
  • Page 26 ST-11 Speed gate, STD-11 Double-sided section Unpack the Master section. Do not work alone! Carefully take the section out of the box by holding it by the top duct. Unpack the section top covers (packed in a separate box). Dismantle parts of the speed gate section as described: •...
  • Page 27 Assembly and Operation Manual characteristics of the access control system and management controller. It is possible to outfit the product with readers manufactured by PERCo (IR13, IR19) or third-party manufacturers. Readers must meet the following requirements: overall dimensions (length × width × height) ........max. 155×68×28 mm ID reading range .....................
  • Page 28: Electrical Connection Layout Of The Speed Gate

    ST-11 Speed gate, STD-11 Double-sided section 8.5 Electrical connection layout of the speed gate Figure 17. Connection layout for the ST-11 Speed gate and STD-11 Double-sided sections for arrangement of a checkpoint with several passage zones Table 6. List of the elements of the speed gate’s electrical connection layout...
  • Page 29 Assembly and Operation Manual Figure 18. Electrical connection layout of the speed gate Layout elements are listed in table 6. The equipment marked with an asterisk (*) is not included in the standard delivery set. When the speed gate operates as part of the ACS, it recommended that its RC panel (A3) should be connected to the ACS controller in accordance with the controller’s operational documentation.
  • Page 30: Training Mode

    ST-11 Speed gate, STD-11 Double-sided section 8.6 Training mode The mode allows the initial (closed) position of the speed gate’s swing panels to be regulated manually. Proceed as follows: 1 Turn off the speed gate’s power supply unit. 2 Switch the R2 switch to the ON position (the R1 switch should be in the OFF position) on the control board.
  • Page 31: Assembly And Disassembly Of Speed Gate Components

    Assembly and Operation Manual 8.8 Assembly and disassembly of speed gate components Attention! Speed gate components are made of polished stainless steel and glass. Be careful during the assembly; to prevent the components from falling and being damaged, place them on an even and steady surface with the outside facing upwards, and protect them from scratches.
  • Page 32: Front Panel Of The Side Post

    ST-11 Speed gate, STD-11 Double-sided section 8.8.2 Front panel of the side post Remove the side post’s front panel (10) by moving it down along the post and then pulling it towards yourself, which will bring the panel hooks from slots in the side post (Fig. 20). Be careful not to damage the connection cable! Disconnect the cable connector from the indication board.
  • Page 33: Swing Panel

    Assembly and Operation Manual 8.8.3 Swing panel Two people shall install and remove the swing panels (4). The swing panel is fixed to the rotary support in three places with M10×30 bolts, washers 10, plastic bushings, and M10 nuts (Fig. 21). Use S17 horn-type wrenches.
  • Page 34: Central Post Indication Block

    ST-11 Speed gate, STD-11 Double-sided section 8.8.5 Central post indication block In order to install the central post indication block (5), proceed as follows (Fig. 22): 1. Pull the cable from the central post indication block into the post top duct through the hole above the central post.
  • Page 35: Intrusion Detector Duct Covers

    Assembly and Operation Manual Figure 23. Top cover installation 8.8.7 Intrusion detector duct covers Attention! It is not necessary to remove covers of intrusion detector ducts when installing the speed gate; this is required only during maintenance or repairs. The intrusion detector ducts (top and bottom) contain boards with sensors. Figure 24.
  • Page 36: Operation

    ST-11 Speed gate, STD-11 Double-sided section To remove the cover of an intrusion detector duct, unscrew the cover-fixing screw through the hole in the wall using an SW2 Allen key (see Fig. 24). The cover will partially be withdrawn from the duct by the screw;...
  • Page 37: Potential Control Mode

    Assembly and Operation Manual After sending the Free passage in the set direction command, only the Passage denial or • Single passage in the set direction command can be sent for the opposite direction, and all other commands will be ignored. Table 7.
  • Page 38: Emergency Response

    (clause block 5.2.7) If the fault cannot be eliminated, we advise you to contact the PERCo Technical Support Department.
  • Page 39: Technical Maintenance

    Assembly and Operation Manual 10 TECHNICAL MAINTENANCE Technical maintenance is to be performed by qualified specialists after careful study of this Manual. Attention! To prevent damage and to maintain the appropriate quality of the coating, one needs to clean the surface of the speed gate from dirt regularly, at least once a quarter. Recommendations on how to clean stainless steel can be found in Section 9.
  • Page 40: Appendix 1. Command Transmission Algorithm In Pulse Control Mode

    ST-11 Speed gate, STD-11 Double-sided section APPENDICES Appendix 1. Command transmission algorithm in pulse control mode Passage denial (locked for entry and exit) – active front at the Stop contact while there is a high level at the Unlock A and Unlock B contacts. Both passage directions are blocked at this command.
  • Page 41 PERCo Polytechnicheskaya str., 4, block 2 194021, Saint Petersburg Russia Tel: +7 812 247 04 64 E-mail: export@perco.com support@perco.com www.perco.com...
  • Page 42 www.perco.com...