Appendix 1. Design of different types of turnstile side covers ............37 Appendix 2. Command transmission algorithm in pulse control mode ........... 40 Appendix 3. Command transmission algorithm in potential control mode ........41 Appendix 4. Configuring the PERCo ACS controller for operation with the card capture reader ..41...
You have purchased a high-quality product, which will serve you for many years to come, if you carefully follow installation and operation rules. The Assembly and Operation Manual for the TTD-10A Electromechanical box tripod turnstile with automatic anti-panic barrier arms and expandable design (hereinafter referred to as the Manual) contains data required for safe transportation, storage, installation, operation, and maintenance of the said product.
............ 1361×750×1024 mm Net weight of the turnstile ..................... max. 100 kg Figure 1. Overall dimensions of the TTD-10A turnstile For the turnstile, the manufacturer recommends using power supply units with an output voltage of 12 V DC and a maximum load current of at least 8 A.
Types of side covers and their application are listed in Table 1. The design and dimensions of different types of covers are shown in Appendix 1. Table 1. Types and application of serially produced side covers for TTD-10A turnstiles Type Design...
TTD-10A Electromechanical box tripod turnstile FaceStation 2 or Suprema FaceLite, and the C-10P.2 cover is used for installation of FRTs manufactured by ZKTeco and breathalyzers. Be sure to purchase a pole mounting bracket that matches the product you are installing:...
Page 7
Assembly and Operation Manual Figure 2. Design of the TTD-10A turnstile 1 – main housing; 2 – main top cover; 3 – main cover indication block; 4 – top cover lock; 5 – barrier arm; 6 – standard side modules; 7 – constant indication blocks for the passage direction / denial;...
TTD-10A Electromechanical box tripod turnstile Design The design of the turnstile is shown in Fig. 2. Numbers of the items hereinafter are given in accordance with Fig. 2. The overall dimensions of the turnstile housing are shown in Fig. 1.
Assembly and Operation Manual indicator of passage permission in one of the directions (green – arrow) – indicator of passage denial (red cross) indicator of passage permission in the opposite direction (green – arrow) Figure 3. Mnemonic indicators of the main cover indication block Constant indication blocks (7) on the side modules are designed to point out the direction of passage through the turnstile or of passage denial.
TTD-10A Electromechanical box tripod turnstile Figure 6. Overall view and dimensions of the RC panel 1, 2, 3 – LEFT, STOP, RIGHT buttons for setting operation modes; 4, 6 – green Left and Right indicators; 5 – red Stop indicator There are three control buttons for sending commands on the RC front panel.
Page 11
Assembly and Operation Manual Figure 7. Control logic board (CLB) Table 2. Contact functions of terminal blocks No. Contact Function of the contact Terminal blocks of the CLB.140 control board XT1L (In) Connection of +12 V power supply for the intrusion detector +12V Detector Input for connection of the intrusion detector Common...
TTD-10A Electromechanical box tripod turnstile No. Contact Function of the contact XT4 (Light A) Normally open contact of the control output for remote indication A Common contact of the control output for remote indication A Normally closed contact of the control output for remote indication A...
Assembly and Operation Manual incoming control commands received at other inputs are ignored in this case (see Section 5.3.2). When a low-level signal is applied to the Fire Alarm input, the directions switch to the mode according to signal levels at the Unlock A, Unlock B, and Stop inputs. The activation of the intrusion detector is monitored by removal of a low-level signal relative to the GND contact from the Detector input of the control board.
TTD-10A Electromechanical box tripod turnstile Pulse control mode The mode is used to control the turnstile via its RC panel, WRC, and ACS controller, outputs of which support the pulse control mode. When a control command is sent to standard control inputs, the control signal must last for at least 100 msec.
Assembly and Operation Manual 5.2.9 Control of the built-in card capture reader mechanism The algorithm of the card capture reader mechanism: 1. In the standby mode, the receiving slot of the card capture reader is constantly illuminated by a built-in LED indicator. The identifier of an access card inserted into the receiving slot is read by the integrated reader and sent for analysis to the external ACS controller.
PERCo controllers). XT6 – connector for power supply of the card capture reader (+12V and GND contacts). • XT8 – connector for connecting a reader (made by PERCo) to the RS-485 interface lines (A • and B contacts). XT9 – connector for power supply of the built-in card reader (+12V and GND contacts).
Assembly and Operation Manual Figure 11. Standard RC panel orientation relative to the turnstile housing Table 3. Connection of RC-panel cable wires to the XTU2 terminal block for standard and reverse RC panel orientation RC panel orientation Contact Standard Reverse black black white...
TTD-10A Electromechanical box tripod turnstile The ACS controller outputs are connected to the GND, Unlock A, Stop, and Unlock B contacts of the XTU2 remote terminal block. The ACS controller inputs are connected to the Common, PASS A, and PASS B contacts of the XTU2 remote terminal block and to the Ready and Det Out contacts of the XT1.H terminal block of the control board.
Assembly and Operation Manual a control signal is received from the intrusion detector. The ALARM output is normalized 5 seconds after the activation or when any control command is received. Note: The control signal from the intrusion detector does not activate the ALARM output if the turnstile’s rotary mechanism is unlocked for one of the directions or was locked less than three seconds ago.
TTD-10A Electromechanical box tripod turnstile MARKING AND PACKAGING The turnstile has a marking label and sticker. The label can be found inside the turnstile housing, under the main top cover (2). It identifies the product’s name, serial number, and date of manufacture.
Assembly and Operation Manual Recommendations for preparation of the mounting surface: It is recommended that you should: • mount the turnstile on steady and level concrete (grade 400 or higher, strength class B22.5), stone or similar foundations with a thickness of at least 150 mm; level the mounting surface so that the fixing points of the turnstile housing lie in the same •...
2. Drill holes for anchor sleeves in the floor to fix the turnstile housing in accordance with Fig. 15. Figure 15. Marking layout for the TTD-10A turnstile housing installation 3. If it is necessary to lay cables under the floor surface, prepare a cable duct in the floor so that it leads to the area where these cables enter the turnstile housing.
Page 23
Assembly and Operation Manual Attention! • It is necessary to leave enough length of cables connected to the remote terminal block and control board to enable removal of the bracket and provide access to the rotary group of the barrier arms. Install and fix the housing only after all the cables have been laid inside the turnstile •...
Page 24
The installation of the side covers is detailed in Appendix 1. Attention! Access card readers made by PERCo can be installed inside the side modules on special brackets. If there is a need to install readers made by third-party manufacturers, they must meet the following specifications: overall dimensions of the reader ..........
Page 25
Assembly and Operation Manual Figure 16. Cable routing inside the housing 1 – CLB.140 control board; 2 – side module; 3 – side module indication block; 4 – XTU remote terminal blocks; 5 – power cable; 6 – cable from the RC panel (WRC); 7, 8 –...
Page 26
TTD-10A Electromechanical box tripod turnstile Figure 17. Constant indication block (standard side module) 1 – standard side module; 2 – indication block; 3 – bracket; 4 – plate; 5 – nuts with washers for fixing the indication block; 6 – nuts with washers for fixing the bracket, 7 – screws for fixing the plate...
Page 27
Assembly and Operation Manual Figure 18. Constant indication block (side module with the built-in card capture reader) 1 – side module with the built-in card capture reader, 2 – container cover; 3 – indication block; 4 – nuts with washers for fixing the indication block, 5 – bracket for the card reader...
TTD-10A Electromechanical box tripod turnstile Electrical connection layout of the turnstile and additional equipment Figure 19. Layout of internal connections of the main housing...
Page 29
Assembly and Operation Manual Figure 20. Connection layout of the turnstile (standard TTD-10AB version) and additional equipment Elements of the layout are listed in Table 5. Elements marked with an asterisk (*) are not included in the standard delivery set.
Page 30
TTD-10A Electromechanical box tripod turnstile Figure 21. Example of the connection layout of the turnstile (TTD-10AC version with the card capture reader) and additional equipment Elements of the layout are listed in Table 5. Elements marked with an asterisk (*) are not included in the standard delivery set.
Page 31
Assembly and Operation Manual Table 5. Elements of the connection layouts of the turnstile and additional equipment Legend Name Quantity Figure Main housing 19, 20, 21 Assembled main cover Main cover indication board A2.1 Controller bracket 19, 20, 21 Control logic board CLB.140 19, 20, 21 Rotary group A5.1...
TTD-10A Electromechanical box tripod turnstile OPERATION When operating the turnstile, comply with safety measures in accordance with Section 7.2. Warning! Do not move any objects with the size exceeding the passageway width through the • passage zone. Do not jerk and hit any elements of the turnstile so as to prevent their mechanical •...
Page 33
Assembly and Operation Manual Table 6. Pulse control mode (the J1 jumper is installed) Indication Actions Turnstile status on the on the main cover Command to do via the RC RC panel indication block panel Press the STOP The turnstile is The Stop red button on the RC The red cross is lit...
TTD-10A Electromechanical box tripod turnstile Potential control mode The turnstile control commands are sent, and their indication is displayed in accordance with Table 7. Passage directions are independent of each other, i.e., a command sent for one direction does not change the state of the opposite direction.
Fault signal are not removed, this is probably caused by malfunctions of the units enabling operation of the card capture reader. In this case, it is recommended to contact the PERCo Technical Support Department. Removal and installation of the card container To remove the card container from the turnstile, do the following: 1.
RC panel to the terminal block In case of other faults and defects, please contact the PERCo Technical Support Department (the PERCo TSD). MAINTENANCE The turnstile maintenance is required once a year and in case of any technical failures; the turnstile must be serviced immediately after repair works.
Page 37
17. Check operation of the turnstile in accordance with Section 9 of this Manual. After technical maintenance works and inspections are complete, the turnstile is ready for further operation. In case of any defects revealed during technical maintenance, please contact the PERCo Technical Support Department (the PERCo TSD).
TTD-10A Electromechanical box tripod turnstile TRANSPORTATION AND STORAGE The turnstile in the manufacturer’s packaging is allowed to be transported only in closed transport (railway cars, containers, closed motor cars, ship holds, airplanes, etc.). Do not stack the boxes with the turnstiles during transportation and storage.
Page 39
Assembly and Operation Manual Table of compliance of side cover types, brackets, and installed equipment: Additional equipment Bracket Cover type Suprema FaceStation 2 BS10 C-10P.1 Suprema FaceLite BS11 ZKTeco ProFace X C-10P.2 ZKTeco SpeedFace V5 Figure 25. The C-10P.1 and C-10P.2 side covers 4.
Page 40
TTD-10A Electromechanical box tripod turnstile Figure 27. The C-10F side cover 6. The C-10RC side cover is intended for the installation only into the TTD-10AC turnstile version with the built-in card capture reader. It is made of stainless steel with an ABS plastic insert for the operation of an RFID reader and with a receiving slot of the card capture reader.
Assembly and Operation Manual Appendix 2. Command transmission algorithm in pulse control mode Note: For the RC panel: active front — pressing of the relevant button on the RC panel; • low level — the relevant button on the RC panel has been pressed; •...
In the PERCo-Web software for ACS 1. Log into the system by using a Web browser (see PERCo-Web Admin Guide). 2. Go to the Administration → Configuration section by using the navigation panel.
Page 43
Assembly and Operation Manual 5. In the opened window, select the Additional outputs tab. 6. In the working area of the window, select Additional output No... (number of the output must match the controller output to which the Capture card input of the card capture reader is physically connected).
Page 44
TTD-10A Electromechanical box tripod turnstile • set the Disconnected value for the Normal condition of the contact parameter: • configure the controller’s response to the activation of input No.5 as required by using the output activation or normalization parameters, for example, the activation of additional output No.
Page 45
Assembly and Operation Manual 13. Within the main controller, select the OD controller, which is operated by the card capture reader: Edit button on the page toolbar. The Device properties window will open. 14. Click the 15. Switch to the Reader No... tab (number of the reader must match the reader controlled by the card capture reader).
Page 46
TTD-10A Electromechanical box tripod turnstile 17. Select the Additional outputs activated upon VISITORS valid identifiers presentation group of parameters and choose the following: set For the operation time for the Activation criterion parameter by using the drop-down • list. in the opened list of additional outputs, check Additional output No.3 (number of the •...
Page 47
Using the web interface, you can only configure the simplest algorithm of withdrawing cards from visitors; more advanced settings can be configured by means of the PERCo- Web software. The CT/L04 (CT03) controllers do not support the configuration of operation with the card capture reader via the web interface.
Page 48
TTD-10A Electromechanical box tripod turnstile Set the following parameter values for the output that is physically connected to the Capture • card input of the card capture reader: - Normal state – Not energized, - Function – Output: 3. Add the following internal response in the Configuration Edit Internal responses section: Source type –...
Page 49
Assembly and Operation Manual 4. Any free input of the controller can be used for receiving the Alarm signal sent by the card capture reader. For this purpose, it is necessary to set the type of response to the activation of this input, for example, blocking of the reader in the passage direction that is controlled by the card capture reader:...
Page 50
TTD-10A Electromechanical box tripod turnstile Example of the general view of the Internal responses and Physical contacts sections after configuration (template – “Turnstile”; the card capture reader controls direction 1; Input 6 and Output 3 are used to control the card capture reader, and Input 5 is used to receive the Fault signal: 5.
Need help?
Do you have a question about the TTD-10A and is the answer not in the manual?
Questions and answers