1 APPLICATION The ST-02 Speed gate (hereinafter referred to as the speed gate) is a blocking device with sliding panels and is designed for managing pedestrian flows at checkpoints of administrative buildings, at banks, shops, railway stations, airports, etc.
Page 4
ST-02 Speed gate and STD-02 Double-sided section Figure 1. Overall speed gate dimensions Figure 2. Overall dimensions of the speed gate if several passage zones are arranged...
DC and a maximum load current of at least 10 A. Consumption current and power consumption are specified for each ST-02 or STD-02 product separately. The maximum length of the RC-panel cable amounts to 40 m (to be supplied upon request).
• It is possible to organize a checkpoint with passage zones of different widths: 600 and 900 mm. For this purpose, the following products are available: ST-02.600/900 (to be supplied upon request) and STD-02.900 with a sliding panel outreach limiter installed on one side.
Page 8
(9, 10) from the delivery set of this speed gate (double-sided section) (see Fig. 4). Figure 3. Overall view and design of ST-02 1 – glass sliding panel; 2 – filling glass; 3 – glass top cover; 4 – central insert; 5 – upper indication block;...
Page 9
Assembly and Operation Manual Figure 4. Overall view and design of STD-02 1 – glass sliding panel; 2 – filling glass; 3 – glass top cover; 4 – central insert; 5 – upper indication block; 6 – side panel; 7 – front panel; 8 – front indication block; 9 –...
ST-02 Speed gate and STD-02 Double-sided section 5.2.1 Section Each section constitutes a single structure. There are two glass top covers (3) that cover the top of the section. Between the glass covers on top of the section, there is a central insert with grooves for a sliding panel (sliding panels) and for filling glass.
Assembly and Operation Manual the speed gate top cover inside the housing, Fig. 19). By default, the cable is connected to the ARROW connector, which enables the display of the white arrow. It is necessary to remove the glass top cover (3) in order to access the indication control module (see Fig. 26). 5.2.3 RC panel The RC panel (11) is a small desktop device in a housing made of impact-resistant ABS plastic.
ST-02 Speed gate and STD-02 Double-sided section XP3 (+12V) – connector for switching on LED indication on the control board. By default, the • jumper is installed, which implies that the indication is switched on. • XP4 (Update) – connector for switching the control board to the built-in software update mode via the USB interface.
Page 13
Assembly and Operation Manual Figure 7. Overview of the remote terminal block Table 1. Contact functions of the remote terminal block No. Contact Master section Slave section +24V External power supply connection Not used +24V Power supply to the Slave section (DC cable Power supply from the Master connection) section (DC cable connection)
ST-02 Speed gate and STD-02 Double-sided section The Slave section uses a similar remote terminal block to connect the power supply and section drive control cables, DC (9) and CAN (10), as well as, if necessary, the connection cable for a reader to be integrated.
Assembly and Operation Manual 5.2.7 Control modes There are two speed gate control modes, namely, pulse and potential. In both modes, the speed gate is controlled by sending commands (i.e., control signal combinations) to the Unlock A, Stop, and Unlock B control inputs and to a special Fire Alarm control input. The control command sending algorithm changes depending on the selected mode.
Page 16
Under the normal control mode (the MODE2 jumper is installed by default), the “safe” zone is the whole passage zone of the ST-02 speed gate, and if the enhanced control mode is activated, with the MODE2 jumper being removed, the “safe” zone is limited to a required narrow area adjacent to the sliding panels of the speed gate.
Assembly and Operation Manual The microcontroller will deactivate the alarm mode after the user leaves the passage zone. The sound alarm will be switched off. In the normally open operation mode, the speed gate’s sliding panels will move apart and open the passage zone. In the potential control mode, the speed gate operation algorithm depends on commands of the external ACS controller.
ST-02 Speed gate and STD-02 Double-sided section 5.3.1 RC panel connection The RC panel is connected with a flexible multicore cable to the Unlock A, Stop, Unlock B, Led A, Led Stop, Led B, Sound, and GND contacts of the remote terminal block in accordance with the electrical connection layout of the speed gate (see Fig.
Assembly and Operation Manual If a control signal is sent to the Fire Alarm input and held for at least 2 seconds , the speed gate switches to the Fire Alarm mode. In this case: if the speed gate’s sliding panels have been closed, then they will open and remain open for •...
ST-02 Speed gate and STD-02 Double-sided section Output stages – relay contacts (Fig. 11) with the following signal characteristics: maximum commutation DC voltage ................42 V maximum commutation current .................. 0.25 A closed contact resistance ................max. 0.15 Ohm 5.4.2 Siren...
The total number of boxes (assemblies) depends on the ordered delivery set. Overall dimensions of transportation boxes (length × width × height): ST-02.600: box No.1, box No.3 ..................205×45×121 cm box No.2, box No.4 ..................131×45×27 cm STD-02.600:...
ST-02 Speed gate and STD-02 Double-sided section Power supply units shall be installed in accordance with safety measures stipulated in their operational documentation. Operation safety Observe general electrical safety rules when operating the speed gate. Attention! • Do not operate the speed gate in conditions that do not comply with the requirements given in Sect.
Electrical connection layouts are shown in Sect. 8.6. The item numbers are stated in accordance with Fig. 3 and 4. In the course of the installation, refer to a video tutorial for assembly and installation of ST-02, which is available on the PERCo website at www.perco.ru.
Page 24
Insert the anchor sleeves into the holes you have drilled so that they are flush with the floor surface. Unpack the Master section (ST-02/M, boxes No.1 and No.2). Note: Box No. 1 (3) consists of a bottom, to which a section of the speed gate is fastened with transport bolts, and a top box.
Page 25
Route the DC and CAN cables from the Slave section in the same manner. If necessary, install other double-sided sections (paragraphs 14 to 16). Unpack and install the Slave section (ST-02/S, boxes No.3 and No.4). Follow the steps specified in paragraphs 7 – 11.
Page 26
ST-02 Speed gate and STD-02 Double-sided section contacts of the control board (X2 and X3 connectors, Fig. 6). An example of the connection layout is shown in Fig. 18 . Note: It is recommended to install the ACS controller with its Ethernet connector facing the direction of the sliding panel’s motor drive to ease access to it in the future.
Figure 13. Marking layout for installation of the speed gate sections with a passageway width of 600 mm (ST-02.600, STD-02.600) The size of the holes in the layouts is indicated for anchors of the PFG IH 10 SORMAT type; when using other...
Page 28
ST-02 Speed gate and STD-02 Double-sided section Figure 14. Marking layout for installation of the speed gate sections with a passageway width of 900 mm (ST-02.900, STD-02.900) Figure 15. Marking layout for joint installation of the speed gate sections with different passageway widths...
Assembly and Operation Manual 8.6 Electrical connection layouts of the speed gate Figure 16. Connection layouts of the ST-02 Speed gate and STD-02 Double-sided sections for arrangement of a checkpoint with several (N) passage zones...
Page 30
ST-02 Speed gate and STD-02 Double-sided section Figure 17. Electrical connection layout of the speed gate...
Page 31
Assembly and Operation Manual Table 4. List of the elements of the speed gate’s electrical connection layout Quantity, Legend Name Master section (side of the section) A1.1 Remote terminal block (DIN rail) of the Master section A1.2 Control board Slave section (side of the section) A2.1 Remote terminal block (DIN rail) of the Slave section RC panel...
ST-02 Speed gate and STD-02 Double-sided section 8.7 Assembly and disassembly of speed gate parts and elements Attention! Parts of the speed gate housing are made of polished stainless steel and glass. Be careful and diligent; to prevent the parts from falling and being damaged, place them on an even and steady surface with the outside facing upwards, and protect them from scratches.
Assembly and Operation Manual Figure 20. Removal of the section from its base 8.7.3 Removal and installation of the removable part of the section housing It may be necessary to remove one of the two removable parts of the housing (or both parts simultaneously) in order to route the connection cables inside the speed gate housing (e.g., to the built-in controller or reader) (see Fig.
ST-02 Speed gate and STD-02 Double-sided section Figure 21. Removable part of the speed gate housing 8.7.4 Installation and removal of the central insert Figure 22. Installation of the central insert...
Assembly and Operation Manual Follow these steps in order to mount the central insert: 1. Take the central insert from the delivery set, and mount it into place, making sure that its grooves are positioned in accordance with the location of the sliding panels. 2.
ST-02 Speed gate and STD-02 Double-sided section Follow these steps to install the sliding panel (2) on the speed gate section: 1. Apply power to the speed gate and wait for a few seconds. The motor drive will operate according to the calibration algorithm and move the sliding panel’s mounting bracket to the position closest to the exit point from the section housing.
Assembly and Operation Manual After installing the panels, check the evenness of the gaps between them and the speed gate housing; if necessary, the gaps can be regulated with adjusting plates (see Section 8.7.3). The side panels are removed in reverse order. Figure 25.
Page 38
(see Fig. 27). Moreover, the customer can avail themselves of the services of special companies dealing with professional glass polishing or purchase new covers for replacement from PERCo. Figure 27. Gluing a rubber pad on the glass top cover...
Assembly and Operation Manual 8.7.9 Passageway width reduction for the STD-02.900 section Design of the STD-02.900 Double-sided section allows you to reduce the outreach distance of the sliding panel from the housing to 280 mm in order to arrange a 600 mm wide passage zone on one side.
Page 40
ST-02 Speed gate and STD-02 Double-sided section Figure 29. Installation of stops of the sliding panel outreach limiter Figure 30. Motor drive board...
Assembly and Operation Manual 9 OPERATION When operating the speed gate, comply with safety measures in accordance with Sect. 7.2. Attention! • Do not move any objects with the size exceeding the passageway width through the passage zone. • Do not jerk and hit any elements of the speed gate. Do not dismantle or adjust mechanisms ensuring the speed gate operation.
ST-02 Speed gate and STD-02 Double-sided section After sending the Free passage in the set direction command, only the Passage denial or Single • passage in the set direction command can be sent for the opposite direction, and all other commands will be ignored.
Assembly and Operation Manual Indication Speed gate status Required to Indication Normally Commands Normally open ensure RC panel blocks of the closed mode top covers mode Low level on the The green Left Green arrow contact of the or Right for the set The sliding panels are open Direction...
ST-02 Speed gate and STD-02 Double-sided section 11 TRANSPORTATION AND STORAGE The speed gate may be stored in dry indoor facilities at an ambient air temperature from -40°C to +50°C and relative air humidity of up to 80% at +15°C. The storage premises must be free of acid and alkali vapors as well as corrosive gases.