Barrier arm ..........................3 Note: Type of barrier arms is chosen by the buyer when ordering turnstile and specified in TTD-03.2 Certificate. Type of manufactured barrier arms: Standard and Anti-panic drop arms. Maximum allowable cable length is 50 m (available on request)
WRC kit ............................1 Note: WRC kit consists of a receiver and 2 transmitters (tags) with operation range up to 40 m. Fig. 1. TTD-03.2 box tripod turnstile. Overall dimensions 5 PRODUCT DESCRIPTION 5.1 Main features The turnstile can be operated both autonomously with the RC panel or WRC and with an ACS.
TTD-03.2 Electromechanical Box Tripod Turnstile • The arm rotation optical sensors are built in the turnstile housing to ensure accurate count inputs to ACS. The mechanical release lock is built in the turnstile housing to ensure the turnstile unblocking •...
TTD-03.2 Electromechanical Box Tripod Turnstile Fig. 3 RC-panel 1, 2, 3 – buttons LEFT, STOP, RIGHT for setting the passage mode; 4, 6 – green indicators «Left», «Right»; 5 – red indicator «Stop» 5.2.4 Control board Turnstile control board (see Fig. 4) located inside the turnstile housing under the left-side outer panel (2).
Operation manual The CLB (see Fig. 3) contains: control mechanism connector – “X1” (Control) (using the turnstile cable for connection to the • “X1” connector of the control mechanism); • connector block for connection of the RC panel / WRC / ACS controller inputs and the emergency unblocking device —...
TTD-03.2 Electromechanical Box Tripod Turnstile Fig. 5. Control elements of an external device a normally open relay contact Fig. 6. ACS control element – circuit with open-collector output Fig. 7. Output cascades for PASS A, PASS B, Ready, Det Out and Alarm 5.2.6 Control modes of the turnstile...
Operation manual Control of the turnstile is effected by input of the controlling signal to the turnstile in both control modes. The passage waiting time at the pulse control mode is 5 seconds at that and it does not depend on the controlling signal (pulse) duration. At the potential control mode, the passage waiting time is equal to the duration of controlling signal.
TTD-03.2 Electromechanical Box Tripod Turnstile 5.3.1 Operation with the RC panel When the buttons on the RC-panel are pressed (the STOP button and the two other buttons corresponding to the passage directions), contacting of the relevant Stop, Unlock A or Unlock B with the GND occurs (i.e.
Page 13
Operation manual Attention! Only the manufacturer should carry out the installation of the intrusion detector on the turnstile housing. If the turnstile is blocked (“Always locked” mode or “Both directions closed” one, see Tables 3 and 4) and a signal comes from the intrusion detector, the “Alarm” signal is generated. The “Alarm” signal is disabled after 5 sec.
TTD-03.2 Electromechanical Box Tripod Turnstile 5.5 Operation contingencies and response The turnstile is capable to provide information on the following operation contingencies: unauthorized access; • • passage delay for more than 30 sec; • one or both optical sensors of arm rotation out of order.
Operation manual 8 INSTALLATION INSTRUCTIONS 8.1 Installation details It is recommended: to mount the turnstile on steady and level concrete (grade 400 or higher, strength group • V22.5), stone or similar foundations at least 150 mm thick; to level the foundation so that the anchoring points of the turnstile lie in the same plane (to be •...
TTD-03.2 Electromechanical Box Tripod Turnstile Cable length The maximum allowed length of the RC panel / WRC / ACS controller cable is not more than 50 m. The maximum allowed length of the turnstile power supply cable depends on the cable cross- section and should be: •...
Page 17
Operation manual cover (1) on the frame (3). At that the cross angle sections on the turnstile housing cover (1) should be maximum close to relative plug-in guides in the frame (3). Adjust the turnstile housing cover (1) by moving it from right to left against stop and after fix it by the turnstile housing cover lock (9).
TTD-03.2 Electromechanical Box Tripod Turnstile 17. Control the turnstile housing and barrier arms fastening, check serviceability and accuracy of all the electrical connections. 18. Run a test switching-on of the turnstile as specified in Chapter 10. Check operation of the intrusion detector and the siren (if included in the delivery set).
TTD-03.2 Electromechanical Box Tripod Turnstile Table 2. Pulse control mode (the jumper is set on the connector J1) Indication on the Response turnstile Indication on the № Actions to do turnstile housing to the barrier arm operating RC- panel display...
Operation manual Table 3. Potential control mode (the jumper is taken off from the connector J1) Indication Indication on the turnstile Response to the barrier № Actions to do on the RC- turnstile housing operating arm turning panel display modes The high level is The red on contacts...
TTD-03.2 Electromechanical Box Tripod Turnstile 9.5 Mechanical unblocking of the turnstile Possibility to unblock the turnstile manually is specially provided for unblocking of the turnstile in the emergency mode at the power supply failure. To unblock the turnstile, it is necessary to insert the key (8) into the mechanical release lock (7) and turn it clockwise up to the stop (the lock cylinder moves out of the case).
2. mount the turnstile housing cover (1) in the reverse order as described above. The housing cover mounting does not need much effort. In case of any defects revealed during visual check please apply to PERCo Technical Support Department. Fig. 14. Location of the interior components of the turnstile housing...
TTD-03.2 Electromechanical Box Tripod Turnstile Appendix А Control signal algorithm at pulse control mode The command is a signal active front (signal transfer from the high level to the low level) at any of the contacts at presence of the corresponding signal levels at the other contacts. The following commands can be formed by sending a low-level signal to the contacts Unlock A, Stop and Unlock B of the XT1.L connector...
Need help?
Do you have a question about the TTD-03.2 and is the answer not in the manual?
Questions and answers