CONTENTS APPLICATION......................3 OPERATION CONDITIONS..................3 TECHNICAL SPECIFICATIONS .................4 DELIVERY SET......................5 Standard delivery set.....................5 Optional equipment supplied on request ...............5 PRODUCT DESCRIPTION ..................7 Main features......................7 Design ........................7 Control over the turnstile ..................11 Input and output control signals and their parameters.........12 Control modes .....................13 Operation with RC panel ..................14 Operation with WRC....................15 Operation with ACS controller ................15...
You have purchased a high quality product, which will be long lasting in operation provided that installation and operation rules are observed. The assembly and operation manual (hereinafter - the Manual) for the TTR-04CW electromechanical tripod turnstile (hereinafter - the turnstile) contains data that is necessary for the most full use of operating advantages of the turnstile as well as chapters on packaging, installation and maintenance.
Assembly and Operation Manual TECHNICAL SPECIFICATIONS Power supply: turnstile input voltage ................12±1.2 DCV operating voltage of the heating system with thermocontrol ....24±2.4 ACV Consumption current: of the turnstile (without heating system with thermocontrol) ..... max. 0.7 A of the heating system with thermocontrol ..........max. 2.5 A Power consumption: of the turnstile (without heating system with thermocontrol) ......
TTR-04CW Electromechanical Tripod Turnstile PRODUCT DESCRIPTION 5.1 Main features The turnstile can be operated from the RC panel or WRC kit as well as from an ACS. The turnstile is designed either for indoor application or outdoor under shelter (see Clause 2) and is equipped with a heating system with thermocontrol.
Page 9
Assembly and Operation Manual Figure 3. LED indication display 5.2.3 The RC panel/ WRC/ ACS controller (10) and the turnstile power supply unit (8) are connected to the CLB with the cables (9 and 11) in accordance with the connection layout (see Fig.
Page 10
TTR-04CW Electromechanical Tripod Turnstile The RC panel is connected to the CLB with a multicore cable (6) via the “XT1.L” connector block (Ref. Fig. 5 and 6). If the turnstile orientation relatively to the operator’s terminal is not standard (e.g. the...
Page 11
Assembly and Operation Manual Figure 6. Connection layout...
TTR-04CW Electromechanical Tripod Turnstile Table 1. Legend to Fig. 6 Legend Item Q-ty Note A1*, A2* Remote indicators for directions of A and B Remote indicator power supply Siren 12 V DC Turnstile power supply 12V DC, 1A CLB-110 Control mechanism...
Assembly and Operation Manual 5.3.6 The ACS controller inputs are connected to the contacts Common, PASS A, PASS B, Ready and Det Out of the XT1.H connector block. 5.3.7 Pin assignments of the CLB connector blocks are given in Fig. 5 and on a label located on the inner surface of turnstile cover (2) with LED indication display (2).
TTR-04CW Electromechanical Tripod Turnstile Figure 7. ACS control element — normally open relay contact Figure 8. ACS control element — circuit with open-collector output Figure 9. Output cascades for PASS A, PASS B, Ready, Det Out and Alarm 5.5 Control modes 5.5.1 There are two modes of the turnstile control - a pulse control mode and a potential...
Assembly and Operation Manual 5.5.3 Control over the turnstile is effected by input of the control signal to the turnstile at both control modes. The passage waiting time in the pulse control mode is 5 seconds regardless of the control signal length. In the potential control mode the passage waiting time equals the length of the control signal.
TTR-04CW Electromechanical Tripod Turnstile 5.6.2.3 The microcontroller traces the status of the optical arm rotation sensors, which become active/passive in a certain consequence at the barrier arm rotation, and counts the time passed since the moment of pushing the RC button corresponding to the permitted passage direction A (B).
Page 17
Assembly and Operation Manual If the turnstile is locked (the “Always locked” mode /“Both directions closed” mode when both directions are locked, Tables 2 and 3) and a signal comes from the intrusion detector, the “Alarm” signal is generated. The “Alarm” signal is disabled after 5 sec. or by executing of any received command.
TTR-04CW Electromechanical Tripod Turnstile 5.10 Key override control 5.10.1 The key override option allows an operating technician to unlock both directions of the turnstile if there is need to override the access control system or in case of emergency or power failure.
Assembly and Operation Manual MARKING AND PACKAGING The turnstile has the marking on the turnstile housing in the form of a label located on the inner panel of the turnstile housing. The label contains manufacturer’s trademark and contact details, year and month of production, operating voltage and power consumption of the turnstile.
TTR-04CW Electromechanical Tripod Turnstile INSTALLATION INSTRUCTIONS 8.1 Installation details It is recommended: to mount the turnstile on steady and level concrete (grade 400 or higher, strength group V22.5), stone or similar foundations at least 150 mm thick; to level the foundation so that the anchoring points of the turnstile lie in the same plane (to be verified with a builder’s level);...
Assembly and Operation Manual Hard wire 1.5 m long for cable pulling. Measuring tape (2 m); Slide caliper. Note: It is allowed to use other testing equipment and measuring tools provided the equipment in use ensures the required parameters and measurement accuracy. 8.3 Cable length The maximum allowed length of the RC panel / WRC / ACS controller cable is no more than 40 m.
Page 22
TTR-04CW Electromechanical Tripod Turnstile Figure 12. Floor anchor position and cable entries for housing installation 10. Connect the RC panel cable (11) (WRC / ACS controller) to XT1.L connector block. 11. Connect the additional equipment if necessary (intrusion detector and a siren;...
Assembly and Operation Manual OPERATION INSTRUCTIONS Follow the turnstile operation safety requirements (see Clause 7.2). It is prohibited! To move through the turnstile passage area any objects with dimensions exceeding the width of the passageway. To jerk hit barrier arms, turnstile housing and light indication display so as to prevent their mechanical deformation.
Page 24
TTR-04CW Electromechanical Tripod Turnstile passage in one direction the countdown of the passage waiting time (5 sec.) for the opposite direction is recommenced. Table 2 Pulse control mode (the jumper is set on the J1 connector) The turnstile Indication Actions...
Assembly and Operation Manual Note: Pressing the button on the RC panel corresponds to the low-level signal supply to the contacts (Unlock A, Unlock B and Stop) of the XT1.L connector block relatively to the contact GND. 9.3 Turnstile operating modes in potential control mode See Table 3 for the operating modes set from the RC panel.
TTR-04CW Electromechanical Tripod Turnstile 9.4 Actions in emergency For urgent evacuation of people from business facilities in case of fire, natural calamities and other emergencies, the additional emergency exit should be provide. To provide unobstructed and fast escape routes in emergency cases through the turnstile, the key override control is used.
remove plastic plugs (13) out of the holes in the turnstile housing base; tighten the anchor bolts (12); put the plastic plugs (13) into their places). In case of any defects revealed during visual check please apply to the PERCo Technical Support Department (the PERCo TSD).
TTR-04CW Electromechanical Tripod Turnstile Figure 13. Location of the interior components of the turnstile housing (CLB is not shown) TRANSPORTATION AND STORAGE The turnstile in the original package should be transported in closed freight containers or in other closed type cargo transport units. During storage and transportation, the boxes can be stacked no more than 4 layers high.
Assembly and Operation Manual Appendix A Control signal algorithm at pulse control mode The following commands can be formed by sending a low-level signal to the contacts Unlock A, Stop and Unlock B of the XT1.L connector block relatively to the contact GND (The command is a signal active front (signal transfer from the high level to the low level) at any of the contacts at presence of the corresponding signal levels at the other contacts): Always locked (closed for entry and exit) -...
TTR-04CW Electromechanical Tripod Turnstile At this command passage direction B opens until the command “Always locked” is received and the status of passage direction A does not change. Free passage (open for passage in both directions) - Active front is at contact Unlock A while there is a low level at contacts Unlock B and Stop,...