PERCo TTR-04CW-24 Assembly And Operation Manual

PERCo TTR-04CW-24 Assembly And Operation Manual

Electromechanical tripod turnstile

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TTR-04CW-24 and is the answer not in the manual?

Questions and answers

Summary of Contents for PERCo TTR-04CW-24

  • Page 2 Electromechanical Tripod Turnstile PERCo-TTR-04CW-24 Assembly and Operation Manual...
  • Page 3: Table Of Contents

    CONTENTS APPLICATION......................3 OPERATION CONDITIONS..................3 TECHNICAL SPECIFICATIONS .................4 DELIVERY SET......................5 STANDARD DELIVERY SET ................5 OPTIONAL EQUIPMENT SUPPLIED ON REQUEST...........5 PRODUCT DESCRIPTION ..................7 Main features......................7 Design ........................7 Control over turnstile .....................9 5.3.1 Control with the remote control panel.............9 5.3.2 Operation from an ACS via the CU “ACS” connector ........9 Unlocking of the turnstile with a mechanical release key........11 MARKING AND PACKAGING...................12 SAFETY REQUIREMENTS..................12...
  • Page 4: Application

    You have purchased a high quality product, which will be long lasting in operation provided that installation and operation rules are observed. The assembly and operation manual (hereinafter - the Manual) for the TTR-04CW-24 electromechanical tripod turnstile (hereinafter - the turnstile) contains data that is necessary for the most full use of operating advantages of the turnstile as well as chapters on packaging, installation and maintenance.
  • Page 5: Technical Specifications

    Assembly and Operation Manual 3 TECHNICAL SPECIFICATIONS Power supply ................... 220±22V AC / 50±1Hz Turnstile power consumption (without heating system with thermocontrol) ..max. 20 W Turnstile operating voltage from external power supply ........12±1.2V DC Turnstile power consumption from external power supply ........max. 15 W Operating voltage of the heating system with thermocontrol ......
  • Page 6: Delivery Set

    TTR-04CW-24 Electromechanical Tripod Turnstile 4 DELIVERY SET 4.1 STANDARD DELIVERY SET Basic equipment: Turnstile housing with control cable and power cable of the heating system with thermocontrol ..............1 RC panel with cable ....................1 Barrier arm .........................3 Mechanical release key ....................2 Control unit with a battery 1.2 Ah, 12 V ..............1...
  • Page 7 Assembly and Operation Manual Fig. 1 TTR-04CW-24 overall view 1 – turnstile housing; 2 – barrier arm; 3 – control unit; 4 – RC panel; 5 – plug; 6 – RC cable; 7 – turnstile housing cable; 8 – AC power cables;...
  • Page 8: Product Description

    TTR-04CW-24 Electromechanical Tripod Turnstile 5 PRODUCT DESCRIPTION 5.1 Main features  The turnstile can be operated from the RC panel or by a WRC, as well as from an ACS.  The turnstile housing is supplied with a safe voltage — no more than 14 V, with the heating system with thermocontrol in operation —...
  • Page 9 Assembly and Operation Manual Fig. 2 Control unit If the turnstile housing installation is not standard (e.g. the operator’s terminal is placed at the backside of the turnstile housing and not at the front side), the RC panel orientation towards the turnstile housing can be changed by switching the RC panel over to the “Wireless”...
  • Page 10: Control Over Turnstile

    TTR-04CW-24 Electromechanical Tripod Turnstile WARNING! To avoid accidental power-up of the SPS during storage or transportation, a “Bat/2А” fuse is not installed and is provided together with a set of spare parts. The CU front panel has the following LED indicators (Fig. 2): ...
  • Page 11 Assembly and Operation Manual The arm rotation sensors, placed inside the turnstile housing, track passages through the turnstile. A passage direction is determined according to sequence of sensors actuation. The signals are generated at the contacts “Sens R/Pass R” and “Sens L/Pass L” of the CU “ACS”...
  • Page 12: Unlocking Of The Turnstile With A Mechanical Release Key

    TTR-04CW-24 Electromechanical Tripod Turnstile or after the passage has been effected (turn of barrier arms. The signal to “Auto/SYS” contact must be transmitted prior to the CU power-up. To set the passage waiting time from an ACS it is recommended to install a jumper at the ACS cable header between contacts 5 and 13.
  • Page 13: Marking And Packaging

    Assembly and Operation Manual 6 MARKING AND PACKAGING The turnstile has the following marking:  on the turnstile housing — a label located inside on the side of the turnstile housing (to get access to the above label unscrew the fixture bolt close to the lock (10) with a socket wrench S10 and carefully lift the cover up with the LED indication display (12)).
  • Page 14: Installation Instructions

    TTR-04CW-24 Electromechanical Tripod Turnstile 8 INSTALLATION INSTRUCTIONS 8.1 Installation details It is recommended:  to mount the turnstile on steady and level concrete (grade 400 or higher), stone or similar foundations at least 150 mm thick;  to level the foundation so that the anchoring points of the turnstile lie in the same plane;...
  • Page 15: Installation Tools

    Assembly and Operation Manual 8.2 Installation tools  1.2 - 1.5 kW hammer drill;  16 mm hard – alloy drill bits for anchor bolt sleeves;  5 mm hard-alloy drill bits for the CU wall mounting dowels;  Crosshead screwdriver No. 2 (150 mm); ...
  • Page 16 TTR-04CW-24 Electromechanical Tripod Turnstile Fig. 5 Floor anchor position and cable entries for turnstile housing installation Fig. 6 Wall dowel position for the CU installation...
  • Page 17: Operation Instructions

    Assembly and Operation Manual 9 OPERATION INSTRUCTIONS Attention! Observe general electrical safety requirements during the turnstile operation. WARNING! It is prohibited:  to use abrasive or chemically active substances for cleaning the external surfaces;  to move through the turnstile passage area any objects with dimensions exceeding the width of the passageway;...
  • Page 18: Operation With The Built-In Sps

    TTR-04CW-24 Electromechanical Tripod Turnstile If the barrier arms do not reset to home position after the start of rotation within 5 seconds, the RC panel starts generating audio signals. It stops signaling when the turnstile gets back to the reset state.
  • Page 19 Assembly and Operation Manual Table 1 The turnstile operating modes Indication Turnstile status Operating Indication on № Actions to do on the LED after arms turning modes the RC panel display The red The “Red Always locked Press the STOP indicator above cross”...
  • Page 20: Actions In Emergency Cases

    TTR-04CW-24 Electromechanical Tripod Turnstile 9.4 Actions in emergency cases For urgent evacuation of people from business facilities in case of fire, natural calamities and other emergencies, the additional emergency exit should be provided. To provide unobstructed and fast escape routes in emergency cases through the turnstile, the key override control can be used.
  • Page 21: Transportation And Storage

    Assembly and Operation Manual 10 TRANSPORTATION AND STORAGE The turnstile in the original package should be transported in closed freight containers or other closed type cargo transport units. During storage and transportation the boxes can be stacked no more than 4 layers high. Storage of the turnstile housing is allowed in dry indoor facilities at the ambient air temperature from -40°С...
  • Page 22  remove 4 plastic plugs (5) out of the holes in the turnstile housing base;  tighten the anchor bolts with a socket wrench S17;  put the plastic plugs (5) into their places. In case of any defects revealed during visual check please apply to the PERCo Technical Support Department (the PERCo TSD).
  • Page 23: Appendix. Connection Layout Of Control Devices

    Assembly and Operation Manual APPENDIX. Connection layout of control devices Fig. 8 Connection layout of control devices Table 3 Connection layout elements Symbol Name Q-ty Note Control unit CU-02N Remote control panel H-06/4.100 Turnstile housing T-04W-24 Wireless remote control MSRF-4 Power supply of the turnstile 12V, 1.2А...
  • Page 25 PERCo P.O. Box 87, Saint Petersburg, 194295, Russia Tel: +7 812 321 61 72 Fax: +7 812 292 36 08 E-mail: export@perco.ru support@perco.ru www.perco.com...
  • Page 26 export@perco.ru...

Table of Contents