Download Print this page

ADF Web HD67176-A1 User Manual

Modbus tcp slave / snmp manager - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.001
English
Modbus TCP Slave / SNMP Manager -
Converter
(Order Code: HD67176-A1)
For Website information:
www.adfweb.com?Product=HD67176
For Price information:
www.adfweb.com?Price=HD67176-A1
Benefits and Main Features:
Electrical isolation
Temperature range: -40°C / +85°C (-40°F / +185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual Modbus TCP Slave / SNMP Manager
Document code: MN67176_ENG
For others SNMP products, see also the following links:
Converter SNMP Manager to
www.adfweb.com?Product=HD67041
www.adfweb.com?Product=HD67170
www.adfweb.com?Product=HD67171
www.adfweb.com?Product=HD67172
www.adfweb.com?Product=HD67173
www.adfweb.com?Product=HD67174
www.adfweb.com?Product=HD67175
www.adfweb.com?Product=HD67177
www.adfweb.com?Product=HD67178
www.adfweb.com?Product=HD67753
www.adfweb.com?Product=HD67849
www.adfweb.com?Product=HD67953
www.adfweb.com?Product=HD67986
www.adfweb.com?Product=HD67B47
www.adfweb.com?Product=HD67D40
www.adfweb.com?Product=HD67E24
www.adfweb.com?Product=HD67F40
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Revision 1.001
Pagina 1 di 23
(DMX)
(BACnet Slave)
(CAN)
(CANopen)
(DeviceNet Slave)
(EtherNet/IP Slave)
(Modbus Slave)
(PROFIBUS Slave)
(PROFINET Slave)
(IEC 61850 Server)
(DALI)
(MQTT)
(IO-Link Slave)
(OPC UA Server)
(LoRaWAN)
(EtherCAT Slave)
(LoRaWAN Gateway)
Phone +39.0438.30.91.31

Advertisement

loading
Need help?

Need help?

Do you have a question about the HD67176-A1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD67176-A1

  • Page 1 Industrial Electronic Devices User Manual Revision 1.001 English Modbus TCP Slave / SNMP Manager - Converter (Order Code: HD67176-A1) For Website information: www.adfweb.com?Product=HD67176 For Price information: For others SNMP products, see also the following links: www.adfweb.com?Price=HD67176-A1 Converter SNMP Manager to www.adfweb.com?Product=HD67041...
  • Page 2: Table Of Contents

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 2 di 23 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 3 di 23 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 4 di 23 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 5 di 23 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67176-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6: Characteristics

    Pagina 6 di 23 Industrial Electronic Devices CHARACTERISTICS: The HD67176-A1 is a Modbus TCP Slave / SNMP Manager - Converter. It has the following characteristics: Up to 2000 bytes in reading and 2000 bytes in writing; Isolation between Power Supply - Ethernet.
  • Page 7: Power Supply

    The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC: Device Consumption [W/VA] HD67176-A1 Caution: Not reverse the polarity power HD67176-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 8: Function Modes

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 8 di 23 Industrial Electronic Devices FUNCTION MODES: The device has got two function modes depending on the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 9: Leds

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 9 di 23 Industrial Electronic Devices LEDS: The devices have got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10: Ethernet

    ETHERNET: The SNMP and Modbus TCP connection must be made using Connector3 or Connector4 of HD67176-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps.
  • Page 11: Use Of Compositor Sw67176

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 11 di 23 Industrial Electronic Devices USE OF COMPOSITOR SW67176: To configure the Converter, use the available software that runs with Windows called SW67176. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 12: New Configuration / Open Configuration

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 12 di 23 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “Modbus TCP Slave / SNMP Manager - Converter”...
  • Page 13: Software Options

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 13 di 23 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 14 User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 14 di 23 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 15: Set Communication

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 15 di 23 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, SNMP and Modbus TCP. By Pressing the “Set Communication”...
  • Page 16: Set Snmp Access

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 16 di 23 Industrial Electronic Devices SET SNMP ACCESS: Figure 4: “Set SNMP Manager Access” window By Pressing the “SNMP Manager” button from the main window for SW67176 (Fig. 2) the window “Set SNMP Manager Access” appears (Fig.
  • Page 17 User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 17 di 23 Industrial Electronic Devices In the field “Time” the delay in ms between two SNMP requests is defined (if “On Timer” is checked); In the field “Position” is possible to select the position where take/save the data from/to the internal SNMP array; In the field “Num Bytes”...
  • Page 18: Update Device

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 18 di 23 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary.
  • Page 19 User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 19 di 23 Industrial Electronic Devices Note: When you install a new version of the software, if it is the first time it is better you do the update of the Firmware in the HD67176 device.
  • Page 20: Mechanical Dimensions

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 20 di 23 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 7: Mechanical dimensions scheme for HD67176-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 21: Ordering Informations

    Enclosure Type A: 1M, 35mm DIN Rail mounting Device Family HD67176: Modbus TCP Slave / SNMP Manager - Converter Order Code: HD67176-A1 Modbus TCP Slave / SNMP Manager - Converter ACCESSORIES: Order Code: AC34011 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC Order Code: AC34012 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 22: Disclaimer

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 22 di 23 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 23: Warranties And Technical Support

    User Manual Modbus TCP Slave / SNMP Manager Document code: MN67176_ENG Revision 1.001 Pagina 23 di 23 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...