Download Print this page
Danfoss MP20A User Manual
Danfoss MP20A User Manual

Danfoss MP20A User Manual

Receiver
Hide thumbs Also See for MP20A:

Advertisement

Quick Links

User Manual
Remote Control
MP20A Receiver

Advertisement

loading
Need help?

Need help?

Do you have a question about the MP20A and is the answer not in the manual?

Questions and answers

Summary of Contents for Danfoss MP20A

  • Page 1 User Manual Remote Control MP20A Receiver...
  • Page 2 MP20A Receiver Revision history Table of revisions Date Changed February 2025 Updated safety and installation information 0301 March 2022 Updated safety instructions and technical descriptiono 0201 January 2019 Rebranded to Danfoss Power Solutions 0101 www.danfoss.com © Danfoss | February 2025 BC292562489617en-000301...
  • Page 3 Contents Safety instructions FCC rules......................................4 General safety....................................4 Safety warnings....................................5 Technical description Dimensions......................................6 Hardware description..................................7 MP20A/MP20V detailed description............................7 Installation Receiver installation..................................9 Input and output configuration............................... 10 Digital outputs...................................10 Analog outputs..................................12 Pinout......................................13 Troubleshooting 400 - 900MHz Receiver icon troubleshooting........................14 2.4GHz Receiver Icon Troubleshooting..........................14...
  • Page 4 The following safety instructions must be read carefully to install and use the product properly, and to keep it in perfect working condition, and to reduce the risk of miss use. • Danfoss recommends the use of ESD PPEs (electrostactic discharge personal protection equipment). •...
  • Page 5 Avoid knocking or dropping the product. • Do not use the product if a failure is detected. Changes or modifications not approved by Danfoss can void the user's authority to operate this product. Quick reference precautions © Danfoss | February 2025...
  • Page 6 User Manual MP20A Receiver Technical description MP20 dimensions Dimensions in mm R 2.60 248.91 82.37 R 2.60 R 2.60 R 2.60 81.55 216.00 232.00 © Danfoss | February 2025 BC292562489617en-000301...
  • Page 7 External antenna A60 (433), A70 (870) or 2.4GHz External EEPROM LCD connection RF Module CAN connection CAN power supply BUS termination CAN Signaling internal LEDs DEUTSCH connector pinout MP20A/MP20V detailed description Technical data Specification MP20A MP20V Stop Function (400-900 MHz) Cat. 3-PLd Stop Function (2.4GHz) Cat. 3-PLe...
  • Page 8 Ikargo2, T70/2, T70/2 HALL, IK2, IK3, IK4 Associated Transmitters (2.4 GHz) Ikore, IkoreB, Ikompact, Ikargo1, Ikargo2, IK1-G, IK2, IK3, IK4 Additional Outputs 8 ON/OFF or 2 (PWM or Voltage) or (20 ON/OFF or 5 Analog Inputs) © Danfoss | February 2025 BC292562489617en-000301...
  • Page 9 User Manual MP20A Receiver Installation MP20A receiver installation The below information describes hazards to be aware of during installation and steps to locate the receiver. Risk of shock Completely shut down the machine when installing the receiver. Check the power supply and shut off the main switch to disconnect the interface cable between the receiver and the machine's electrical box.
  • Page 10 45 (stop) for powering up this group of outputs. Maximum 2A per output. As an alternative, the K5-K12 output group can be connected directly to the external general power supply in order to provide a higher capacity of current. © 10 | Danfoss | February 2025 BC292562489617en-000301...
  • Page 11 User Manual MP20A Receiver Installation © Danfoss | February 2025 BC292562489617en-000301 | 11...
  • Page 12 (stop) for powering up the 1-8 outputs. Maximum 2A per output. nSA1-nSA8 have a common contact at pin 47 of the connector. Pin 47 connects with pin 46 (stop) in order to feed nSA1-nSA8 outputs. Maximum 2A per output. © 12 | Danfoss | February 2025 BC292562489617en-000301...
  • Page 13 SA7 (PWM 7 North) SA6 (PWM 6 North) SA5 (PWM 5 North) SA4 (PWM 4 North) SA3 (PWM 3 North) SA2 (PWM 2 North) SA-8 (PWM 8 South) SA1 (PWM 1 North) © Danfoss | February 2025 BC292562489617en-000301 | 13...
  • Page 14 The LEDs on the receiver board are POWER, STATUS, DIAG1, DIAG2, ORDER, RELAY, CANERR and CANRUN in that order. Please do check the following website for further information: https://troubleshooting.dps-rct.com/en/customer-service-center © 14 | Danfoss | February 2025 BC292562489617en-000301...
  • Page 15 Hardware Error Replace Receiver CAN Bus configuration Error Verify CAN Connections, addresses of Expansion boards and Bus terminations Standby and Operation Screen Representation of Inputs and outputs being active at a time © Danfoss | February 2025 BC292562489617en-000301 | 15...
  • Page 16 Phone: +86 21 2080 6201 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.

This manual is also suitable for: