Installation Guide

Remote Control

TM70 and Ikontrol
Danfoss does not take responsibility for incorrect installation or
any frequency interference.
Chance of unintended machine movement on start up.
Ensure the machine is stopped for the entire duration of the
assembly process.
Keep the work area free and wear protective clothing.
Connect the power supply and the output connections using
the connection block diagram provided with the system. The
receiver will enter into scanning mode and show the following:
ORDER
RELAY
ID
DATA
SIGNAL
HARDOK
POWER
CANRUN
CANERR
OFF
ON
BLINKING
LED scanning mode (receiver)
LED
DATA
SIGNAL
HARDOK
POWER
CANRUN
*
Only in receivers with CAN connection (except RCAN)
©
Danfoss | January 2019
Description
There is not another system active
in the area
OFF; channels are signal free
BLINKING; RF signal detected on
the channels
GREEN; Absence of faults on the
boards
Power supply OK
Communications with expansion
*
boards are OK
OUT
IN
RF signal detected
Incorrect ID signal from Ikusi system
Abc
CORRECT ELEMENTS
Abc
INCORRECT ELEMENTS -Check
troubleshooting guide
Display scanning mode (receiver)
1. Place a charged battery in the transmitter
2. Turn the contact key
3. Push and pull out the STOP button
The LED of the transmitter will flash orange-green. If the
transmitter has a display, it displays the identification of the
machine, as well as the battery level
4. Press the start button
The green LED should now light indicating the transmitter
is transmitting
5. Turn off the transmitter using the STOP button
ORDER
RELAY
ID
DATA
SIGNAL
HARDOK
POWER
CANRUN
CANERR
OFF
ON
BLINKING
LEDs operational mode (receiver)
OUT
IN
Incorrect ID ( the icon shows the quality)
No Ikusi RF signal detected(the icon shows the
quality)
Linked state
Correct ID (the icon shows the quiality of the link)
Display operational mode (receiver)
AI293579926818en-000101 | 1

Advertisement

loading

Summary of Contents for Danfoss TM70

  • Page 1: Installation Guide

    Installation Guide Remote Control TM70 and Ikontrol Danfoss does not take responsibility for incorrect installation or any frequency interference. Chance of unintended machine movement on start up. Ensure the machine is stopped for the entire duration of the assembly process.
  • Page 2 10. Tether connection Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.