MAKING MODERN LIVING POSSIBLE CF-RC Remote Controller Installation and User Instruction...
Page 2
Marketing on 0845 121 7400. Certification Mark Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
1. Functional Overview Front – fi g. 1 Display Soft key 1 Soft key 2 Up/down selector Left/right selector Icon for system alarm Icon for communication with Master Controller Icon for switch to 230V power supply Icon for low battery level Note: The Remote Controller has a self-explanatory menu structure, and all settings are easily carried out with the up/down and left/right selectors in combination with the functions of the soft keys, which are...
• Or install a Repeater Unit (CF-RU, see fi g. 5 c), and place it between the Master Controller and the Remote Controller. Note: The link test may take a few minutes depending on the size of the system. Danfoss Heating...
4. Mounting The Remote Controller has been installed – fi g. 2 When the Remote Controller has been installed to the Master Controller (see chapter 2), it can be mounted on the wall by means of the back plate/docking station . The Remote Controller is powered by two AA Alkaline 1.5V batteries.
Here you can disable the cooling function for the room in question. Note: Only available when the Master Controller is in cooling mode. 5.2 Program From the start-up screen, activate the: Program menu to view the two time programming options: Danfoss Heating...
Page 8
5.2.1 Period program: With this program, you can set the room temperature for all Room Thermostats during e.g. a holiday. The start and end date for the program is easily set in a calendar by means of the up/down and left/right selectors (fi...
Page 9
(fi g. 1- / ). You can remove the second period with the normal room temperature by changing the end time of this period to its start time: Danfoss Heating...
Page 10
The second period with the normal room temperature can be added again by means of the up/down selector and by toggling through the fi rst period Confi rm the selected time periods with OK to activate the created program from this overview: Note: The days selected in the program are indicated by more distinct initial capitals.
This Alarm log saves the latest alarms for later access and easy system failure identifi cation. Start-up screen: Here you can choose which room temperature you want displayed on the start-up screen. Danfoss Heating...
Page 12
Service: Here you can confi gure all the outputs of the Master Controller (see fi g. 5-a) for either a fl oor or radiator heating system. With fl oor heating, you can choose regulation by means of an On/Off or a PWM (Pulse Width Modulation) principle.
This indication of Alarm on the Remote Controller and the indication on the Master Controller will continue until the error that caused the alarm has been fi xed. An Alarms menu will be present at the top of the Menu list activated from the start-up screen: Danfoss Heating...
Alarm log through the Setup menu (see chapter 5.3). 6.0 Uninstallation Resetting the Remote Controller, CF-RC – fi g 1: • At the same time, activate the Soft key 1 , the soft key 2 the down selector •...
Link between MCs The indicated Master Controllers have (E24) lost their wireless connection. The battery level of the Remote Controller is low, and the batteries should be replaced. Danfoss Heating...
Need help?
Do you have a question about the CF-RC and is the answer not in the manual?