12.Maintenance

Ionising bars become contaminated with usage, so cleaning of the bar should be scheduled alongside
regular machine maintenance. As well as dirt build-up on the body of the bar, contamination of the
emitter pins will cause a drop in performance.
A bar that requires cleaning will trigger a Clean Pin alert signal and the status LED will flash red. Before
cleaning, ensure the equipment is switched off and electrically isolated.
The emitter pins can be cleaned effectively with a dry brush, which will agitate any accumulated corona
residue.
The body of the bar can be cleaned with a cloth moistened with a small amount of Isopropanol Alcohol
(IPA) or Methylated spirits. Ensure the bar has been left to dry completely before switching the power
on.

13.CE approval

A CE Declaration of Conformity for this product exists and can be provided on request.
14.Health & safety
Emission of Ozone
Considerably lower than the international standard of 0.1ppm.
Output current
The maximum output current is less than 5mA to prevent serious harm to the operator,
nevertheless any contact with the ionising emitter pins should be avoided where possible.
15.Repairs & warranty
The Hyperion 945IPS Pulsed DC Ionising Bar is warrantied by Meech International Ltd. to the original
purchaser against defects in material and workmanship for 2 years after shipment.