The typical Meech 910 installation consists of one or more bars connected to a Meech The typical Meech 910 installation consists of one or more bars connected to a following instructions are observed closely.
Installation of RML Bars Installation of RML Bars Correct positioning of the bar(s) is vital to efficient operation. The general rule is Correct positioning of the bar(s) is vital to efficient operation. The general rule is that that they should be positioned immediately before the problem area, remembering they should be positioned immediately before the problem area, remembering that that subsequent passage of the material over rollers, or friction, can regenerate the static charge.
Page 7
Issue 3 Page 4 Issue 3 28/11/01 Page 5 28/11/01 Free space is needed on opposite side of material, not a roller or solid object. 2. Free space is needed on opposite side of material, not a roller or solid object. 4.
Page 8
28/11/01 28/11/01 4. If bars are needed on each side of the material, they should be staggered. 4. If bars are needed on each side of the material, they should be staggered. 4. If bars are needed on each side of the material, they should be staggered. 50 mm 50 mm FIG 6...
Technical Characteristics Operating voltage : 7 kV Pin energy : 0.15 millijoules Max Temp : 85 deg. C Length : 80 to 4000mm in 20 mm steps. Effective length is 40 to 60 mm less than the effective length. Cable : 2m of screened HT cable as standard, longer lengths can be specified when ordering.
Ionising bars will need periodic wiping to clean grey deposits from the surface of the bar. A cloth moistened with a small amount of IPA or methylated spirits is recommended. Should you have any additional questions regarding the maintenance of Meech equipment please contact Meech International directly or your local Meech distributor.
High voltage electrical equipment should not make contact with water. The model 910 ionising bar forms part of a system, comprising of itself and a Model 904 power supply. (See fig 1) To verify where a fault may have occurred it is important to test each item of the system individually.
Repairs and Warranty The Meech 910 Bar is warranted by Meech Static Eliminators Ltd to the original purchaser against defects in material and workmanship for one year after purchase. Should any malfunction occur, please return the Ioniser directly to us. All products returned to the factory MUST be accompanied by a return authorisation number and must be shipped prepaid.
CE Approval An EC Declaration of Conformity for this product exists in respect of the Low Voltage Directive:72/23/EEC (“LVD”) & Electromagnetic Compatibility Directive: 89/336/EEC (“EMCD”) Health and Safety Emission of Ozone: Considerably below international standard of 0.1ppm.
Page 16
Meech International Meech Static Eliminators USA Inc Meech Elektrostatik SA Meech CE 2 Network Point 2915 Newpark Drive Kaiserbaracke 166 Gábor László utca 2 Range Road, Witney Norton, OH 44203 B-4780 St.Vith Budapest 1041 Belgium Hungary OX29 0YN, UK Tel: +44 (0)1993 706700 Tel: +1 330 564 2000 / 1 800 232 4210 Tel.: +49 (0)6555 3733 399...