7.
Motor requirements
28 | 180R9407 | AQ274347577038en-000902
Installation, Operation and Maintenance APP 21-46 pumps
The power requirements can be determined using one of the following guiding equations:
l/min x barg
Required power =
Calc. factor
1 hp
=
0.75 kW
1 gpm
=
3.79 l/min
1 m
3
/h
=
4.40 gpm
1 kW
=
1.34 hp
1 l/min
=
0.26 gpm
1 gpm
=
0.23 m
3
/h
7.6
Calculation factor for APP 21-46
Name
rpm
APP 21
1200
APP 21
1500
APP 24
1200
APP 24
1500
APP 26
1200
APP 26
1500
APP 30
1200
APP 30
1500
APP 38
1500
APP 46
1780
16.7 x m
3
/h x barg
[kW] or
Calc. factor
Calculation
factor
543
531
547
537
543
534
545
540
541
537
0.´35 x gpm x psig
[kW] or
Calc. factor
© Danfoss | 2023.03