Download Print this page

Danfoss APP 46 Installation, Operation And Maintenance Manual page 24

Advertisement

Operating guide
5.
Flow at di erent rpm
24 | 180R9407 | AQ274347577038en-000902
Installation, Operation and Maintenance APP 21-46 pumps
If the ow required and the rotation speed (rpm) of the
pump is known, it is easy to select the pump tting the
application best by using the diagrams below.
5.7 APP 21-30 ow curves at 60 barg (870 psig)
m
3
/h
32.0
30.0
28.0
26.0
24.0
22.0
20.0
18.0
16.0
14.0
12.0
gpm
140.0
130.0
120.0
110.0
100.0
90.0
80.0
70.0
60.0
50.0
Furthermore, these diagrams shows that the
ow can be changed by changing the rotation
speed of the pump. The ow/rpm ratio is
constant, and the "required" ow can be
obtained by changing the rotation speed to a
corresponding value. Thus, the required rpm
can be determined as:
Required ow x Rated rpm
Required rpm =
Rated ow
APP 30/1200
APP 26/1200
APP 24/1200
APP 21/1200
rpm
APP 30/1200
APP 26/1200
APP 24/1200
APP 21/1200
rpm