PROBLEM
Engine lacks power.
No battery charge DC
output.
MIL codes are flashing.
Engine starts and shuts
off right away.
22
CAUSE
1. Load is too high.
2. Dirty air filter.
3. Engine needs to be serviced.
1. Battery posts corroded.
2. Bad battery cable.
3. Defective battery.
4. Bad receptacle.
1. Multiple.
1. COsense shut-off due to accu-
mulating carbon monoxide if a
red light blinks on the side
panel badge.
2. COsense shut-off due to a
system fault if a yellow light
blinks on the side panel
badge.
3. Engine fault code present.
CORRECTION
1. Reduce load (see
erator Limits
2. Clean or replace air filter.
3. Contact IASD.
1. Clean battery posts.
2. Replace cable.
3. Check battery condition.
Replace if defective.
4. Contact IASD.
Fault Code Example
1. See
contact IASD.
1. Follow all safety instructions
and relocate generator to an
open area outside, far away
from windows, doors and
vents.
2. Start to confirm yellow light
blinks when/if generator shuts-
off. If COsense continues to
fault and shut-off, contact
IASD.
Fault Code Example
3. See
contact IASD.
Owner's Manual for Portable Generator
Know Gen-
).
or
or