Section 2 Electronic Engine Control
Control Panel Components
11
1
Key Start Switch
2
Malfunction Indicator Lamp (MIL)
3
Hour Meter
4
2P 30A Circuit Breaker
12
12
Connector and Receptacle to
Engine Wire Harness
13
Diode Bridge 1
14
Field Boost Relay
15
Starter Relay
16
Main Power Relay
10
3
1
2
4
10
9
Figure 2-31. External Control Panel Components
5
1P 20A Circuit Breaker
6
2P 50A Circuit Breaker
7
50A Outlet (NEMA 14-50R)
8
20A Outlet (NEMA 5-20R)
14
13
15
16
26
Figure 2-32. Internal Control Panel Components
17
Automatic-Reset 6A Circuit
Breaker
18
10 Amp Fuse
19
15 Amp Fuse
20
Current Transformer
21
Terminal Block
22
Control Panel Vent Snap
Bushing and Conduit
5
8
17
25
24
23
6
7
9
30A outlet (NEMA L14-30R)
10
30A outlet (NEMA L5-30R)
11
1P 30A Circuit Breaker
18
19
20
22
23
12-Pin Alternator Receptacle
and Connector (CONN3R/
CONN3P)
24
Diode Bridge 2
25
Ground Terminal
26
Resistor
Diagnostic Repair Manual