KaVo 1.011.6740 Instructions For Use Manual
Hide thumbs Also See for 1.011.6740:

Advertisement

Quick Links

Instructions for use
SMARTmatic PROPHY S19 - 1.011.6740
SMARTmatic PROPHY S19 K - 1.011.6741

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1.011.6740 and is the answer not in the manual?

Questions and answers

Summary of Contents for KaVo 1.011.6740

  • Page 1 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741...
  • Page 2 Distributed by: Manufacturer: KaVo Dental Corporation Kaltenbach & Voigt GmbH 11729 Fruehauf Drive Bismarckring 39 Charlotte, NC 28273 USA D-88400 Biberach Phone: 847 550 6800 www.kavo.com Fax: 847 550 6825...
  • Page 3 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 Table of contents Table of contents 1 User instructions............................. 4 2 Safety ................................6 2.1 Infection hazard ............................. 2.2 Technical condition ..........................2.3 Accessories and combination with other equipment................
  • Page 4 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 1 User instructions 1 User instructions Dear User, congratulations on purchasing this KaVo quality product. By following the instructions below you will be able to work smoothly, economically and safely.
  • Page 5 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 1 User instructions CE mark according to Medical Devices Directive EC 93/42 Consult instructions for use Caution: Consult instructions for use EAC conformity mark (Eurasian Conformity)
  • Page 6 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 2 Safety | 2.1 Infection hazard 2 Safety The instructions for use are a component of the product and must be read carefully prior to use and be accessible at all times.
  • Page 7 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 2 Safety | 2.3 Accessories and combination with other equipment ▶ Do not use motors for unauthorized purposes. 2.3 Accessories and combination with other equipment Use of un-authorized accessories on the device or un-authorized modifications to the device can lead to injury.
  • Page 8 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 2 Safety | 2.5 Service and repair ▶ Have the medical device evaluated by a professional shop with regard to its clean- ing, servicing and functional needs according to an in-house service interval. De- fine the service interval depending on the frequency of use.
  • Page 9 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 3 Description of the product | 3.1 Intended use 3 Description of the product SMARTmatic PROPHY S19 (Mat. No. 1.011.6740) SMARTmatic PROPHY S19 K (Mat. No. 1.011.6741) The SMARTmatic electrical-driven handpieces are dental handpieces according to 21 CFR §...
  • Page 10 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 3 Description of the product | 3.2 Technical Specifications CAUTION US Federal law restricts this device to sale by or on the order of a healthcare profes- sional / dentist.
  • Page 11 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 3 Description of the product | 3.3 Transportation and storage conditions 3.3 Transportation and storage conditions NOTICE Startup after refrigerated storage. Malfunction. ▶ Prior to startup, strongly refrigerated products must be allowed to warm up to a temperature of 20 °C to 25 °C (68 °F to 77 °F).
  • Page 12 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 4 Startup and shut-down 4 Startup and shut-down WARNING Hazard from nonsterile products Infection danger to the care provider and patient. ▶ Before first use and after each use, sterilize the medical device.
  • Page 13 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 5 Operation | 5.1 Attaching the medical device 5 Operation 5.1 Attaching the medical device CAUTION Detachment of the medical device during treatment. Injury or property damage A medical device that is not properly locked in place can become disconnected from the motor coupling and fall off.
  • Page 14 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 5 Operation | 5.3 Attaching the prophylaxis head 5.3 Attaching the prophylaxis head Note All prophylaxis heads with a Doriot connector can be attached. The clamping system is designed for drive shafts working in accordance with ISO 14457 for metallic and ceramic materials: Ø2.35 0/-0.016mm and plastic materials:...
  • Page 15 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 5 Operation | 5.4 Removing the prophylaxis head 5.4 Removing the prophylaxis head ▶ Remove the prophylaxis head axially from the handpiece. CAUTION Hazard due to incorrectly stored instrument.
  • Page 16 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 6 Checking for malfunctions and troubleshooting | 6.1 Checking for malfunctions 6 Checking for malfunctions and troubleshooting 6.1 Checking for malfunctions CAUTION Missing or damaged O-rings.
  • Page 17 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 7 Processing steps in accordance with ISO 17664 | 7.1 Preparations at the site of use 7 Processing steps in accordance with ISO 17664 7.1 Preparations at the site of use WARNING Hazard from non-sterile products.
  • Page 18 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 7 Processing steps in accordance with ISO 17664 | 7.3 Disinfection 7.2.4 Automated internal cleaning KaVo recommends washer disinfectors in compliance with ISO 15883-1, which are operated using alkaline cleaning agents.
  • Page 19 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 7 Processing steps in accordance with ISO 17664 | 7.4 Drying ▶ In order to prevent negative effects on the KaVo medical device, make sure that...
  • Page 20 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 7 Processing steps in accordance with ISO 17664 | 7.5 Care products and systems - Servicing 7.5.2 Servicing with KaVo QUATTROcare Note QUATTROcare 2104 / 2104 A is no longer included in the current delivery program.
  • Page 21 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 7 Processing steps in accordance with ISO 17664 | 7.6 Packaging Servicing the chuck KaVo recommends cleaning and servicing the chuck system once a week using the chuck servicing program integrated in the device.
  • Page 22 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 7 Processing steps in accordance with ISO 17664 | 7.7 Sterilization 7.7 Sterilization Sterilization in a steam sterilizer (autoclave) in accordance with ISO 17665-1 NOTICE Improper service and care.
  • Page 23 Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741 8 Tools and consumables 8 Tools and consumables Available from dental suppliers. Material summary Mat. No. Instrument stand 2151 0.411.9501 Cleanpac 10 units 0.411.9691 Cellulose pad 100 units 0.411.9862...
  • Page 24 12 months from the date of the invoice, subject to the following conditions: In case of justified complaints, KaVo will honor its warranty with a free repair or re- placement, as needed. Other claims of any nature whatsoever, in particular with re- spect to compensation, are excluded.

This manual is also suitable for:

Smartmatic prophy s19 kSmartmatic prophy s191.011.6741